Raket 95 Owner's Manual - 2. Instructions For Handling
www.raketengines.com
6
Raket 95 Manual - English
2. Instructions for handling
and charging a Raket 95
starter battery.
PLEASE NOTE: These instructions
regarding the handling of a Raket 95
starter battery are an important part of
Radne Motor’s delivery of the Raket 95
kart engine. These instructions contain
information about handling of the battery
and the charging of the same. Before you
may use the NiMH battery it is important
that you read these instructions in their
entirety. If in the future you sell your Raket
95 engine together with its starter battery,
then you must ensure that the new owner
receives these instructions.
IMPORTANT! Radne Motor accepts no
responsibility whatsoever for damages to
a Raket 95 engine that may occur if you
use any other battery than a Raket 95
original battery.
If you have previous experience of lead-
acid batteries then please be aware that
NiMH batteries are radically different
from these. As long as a NiMH battery is
used correctly then it is a very good and
environmentally-friendly source of power
that is far superior to both lead-acid and
nickel-cadmium batteries. However, if a
NiMH battery is not handled correctly and
in accordance with these instructions,
such incorrect handling may drastically
shorten the battery’s lifespan, or else
cause injury to people or damage to
property.
Technical Data Raket 95 Battery
Battery type: NiMH
Voltage: 14,4 volt
Capacity: 3000 mAh
Charging power: 1 A, determined by the charger
Charge 5 hours, then maintenance charge
Minimum discharge voltage 11.0 volts
Maintenance charge only by Raket Original special charger
Fuse in the battery cartridge 40 A
Use in temperatures:
Storage 0-50 degrees ambient temperature
Use 0-50 degrees ambient temperature
Charge 0 - 30 degrees ambient temperature
Life expectancy 500 up and discharge cycles
Charger Raket Original special charger for NiMH
Technical Data Raket 95 Battery
Battery type: NiMH
Voltage: 14,4 volt
Capacity: 3000 mAh
Charging power: 1 A, determined by the charger
Charge 5 hours, then maintenance charge
Minimum discharge voltage 11.0 volts
Maintenance charge only by Raket Original special charger
Fuse in the battery cartridge 40 A
Use in temperatures:
Storage 0-50 degrees ambient temperature
Use 0-50 degrees ambient temperature
Charge 0 - 30 degrees ambient temperature
Life expectancy 500 up and discharge cycles
Charger Raket Original special charger for NiMH