Range Senator RFB006 6kW Installation And User Instructions Manual - page 13
13
WARNING: THIS APPLIANCE MUST BE EARTHED.
All exposed pipework must be earthed in accordance with IEE regulations.
After installation, preliminary electrical checks i.e. short circuit, earth continuity, resistance to earth and check for correct polarity etc.
must be carried out.
Before connecting the electrical supply, ensure the system is full of water and set to the correct pressure (pressurized systems), check
for leaks.
IT IS ESSENTIAL THAT ALL THE AIR IS PURGED FROM THE SYSTEM
Only then can the supply be switched on.
On completion of the work the installation must be tested to IEE regulations and an NICEIC inspection and completion certificate must be issued.
Please take note of the installation information. If in doubt please contact your local supplier.
Heating Controls To Comply With The Revised Building Regulations (Part L For England. Part J For Scotland.)
New Dwelling
1. Fully pumped system.
2. Independent temperature and time controls for both heating and domestic hot water.
3. Controls to interlock with the boiler. TRV’s alone do not comply.
4. An automatic bypass is required. Gate-valves do not comply.
5. Split heating circuits into zones:
a. Room thermostat or programmable room thermostats in all zones.
b. A room thermostat or programmable room thermostats in the main zone and TRV’s in all other zones.
6. Cylinder thermostat and zone valve to control stored hot water. Non-electric hot water controllers do not comply.
7. Timed controller for heating and hot water must be provided.
8. A minimum of 2 zones for heating floor spaces greater than 150m
2
.
9. Boiler management control systems meeting specific zoning, timing and temperature requirements are acceptable.
Existing Dwellings
1. When a new installation is fitted, the controls must be as for a new dwelling.
2. When replacing the boiler and/or hot water vessel, the opportunity to improve the controls should be considered to be confident that the
requirements of the Building Regulations are met.