Card Wiring for 12-36 Zone System
A. On back of Distribution Module, remove the two screws on the top left and right and slide cover off unit to
expose internal cards
B. On the top of each card, there is a table indicating port usage:
1. SLT is the port used for connecting Emergency Phones
2. DKP is the port used for connecting Command Center Phone(s)
3. TWT is the port used for outside Telco Line
C. The first card installed will always be:
1. Port 1: (S01-S04) Connection for 4 Emergency Phones
2. Port 2: (S05-S06) Connection for 2 Telco Lines
3. Port 3: (S07-S08) Connection for 2 Command Center Phones
D. Plug RJ45 of wiring harness into appropriate port (see wiring diagram below):
For additional extensions on SLT ports, follow scheme below:
Note: Refer to top of cards to see what type of port and number of extensions.
2005: Blue, Blue-White
2006: Orange, Orange-White
2007: Green, Green-White
2008: Brown, Brown-White
2009: Blue, Blue-White
2010: Orange, Orange-White
2011: Blue, Blue-White
2012: Orange-Orange, White
2013: Blue, Blue-White
2014: Orange, Orange-White
2015: Green, Green-White
2016: Brown, Brown-White
2017: Blue, Blue-White
2018: Orange, Orange-White
2019: Blue, Blue-White
2020: Orange, Orange-White
2021: Blue, Blue-White
2022: Orange, Orange-White
2023: Green, Green-White
2024: Brown, Brown-White
2025: Blue, Blue-White
2026: Orange, Orange-White
2027: Blue, Blue-White
2028: Orange, Orange-White
2029: Blue, Blue-White
2030: Orange, Orange-White
2031: Green, Green-White
2032: Brown, Brown-White
2033: Blue, Blue-White
2034: Orange, Orange-White
2035: Blue, Blue-White
2036: Orange, Orange-White
Note: System uses T568-A for pin-out wiring.