Raychem h910 Installation Instructions Manual

Other manuals for h910: Installation Instructions Manual

Summary of h910

  • Page 1

    Description the wintergard h910 splice and tee kit is for use with wintergard self-regulating heating cables to make splice, tee, and end seal connections. The kit contains materials for one splice and one end seal, or one tee connection and one end seal. This kit does not provide a power connection...

  • Page 2

    1 identify heating cable 2 installation instructions h910 splice and tee kit 2 for all heating cables 3a for h612 and h622 heating cables only 3b for h311, h611, and h621 heating cables only wintergard h311, h611, h621 heating cables with braid but no outer jacket wintergard h612, h622 heating cable...

  • Page 3

    3 installation instructions h910 splice and tee kit 4a for h612 and h622 heating cables only 4b for h311, h611, and h621 heating cables only 5 for all heating cables 6 for all heating cables 7 for all heating cables • unravel the braid back to the outer jacket. • position braid on same side of each ...

  • Page 4

    4 installation instructions h910 splice and tee kit 8 for h612 and h622 heating cables only 9 for all heating cables 10 for all heating cables 11 for all heating cables • remove release paper from mastic strip. • wrap a piece of mastic around the outer jacket on each heating cable section. • pinch t...

  • Page 5

    5 installation instructions h910 splice and tee kit 12 for h612 and h622 heating cables only 13 for all heating cables 14 for all heating cables 15a for h612 and h622 heating cables only 15b for h311, h611, and h621 heating cables only • fold the crimped braid back against the heating cables. • wrap...

  • Page 6

    6 installation instructions h910 splice and tee kit 17a for all installations except gutter/downspout 17b for h612 and h622 gutter/downspout installations 16a for h612 and h622 heating cables only 16b for h311, h611, and h621 heating cables only • shrink the tube completely. Start at end farthest fr...

  • Page 7

    7 installation instructions h910 end seal (for tee connections only) note: the end seal is designed to be installed only once; it cannot be removed from the heating cable once installed. Do not use until ready for final installation. 1 end seal for h612 and h622 1 end seal for h311, h611, and h621 2...

  • Page 8

    ©1997, 1998 raychem corporation printed in usa (y5129) h55073 (pn 585033) 8/98 wintergard is a trademark of raychem corporation. All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their application. ...