Raymarine Base Station Installation And Commissioning Manual - Commissioning
12
LifeTag Installation & Commissioning Guide
Commissioning
Important
Before attempting to use any Tag, ensure the LED indicator on the Tag is flashing GREEN, to show the
Tag is registered with your Base Station.
If a Tag indicator is NOT flashing GREEN, de-register the Tag is as described on
Page 14
, then register
the Tag with the Base Station, as described on
Page 13
.
Do NOT attempt to use any Tag that is not registered.
Commissioning procedure
When the LifeTag system has been installed and all Tags registered, carry out the following
commissioning procedure:
1. Switch on power to the Base Station and check
that the Alarm ‘chirps’ as power is applied.
2. Check each Tag to ensure the LED indicator
briefly flashes GREEN once every 10 seconds,
to indicates that the Tag is ACTIVE. If a Tag is
not active, press and release the push button
to activate the Tag.
3. Take each Tag, one at a time, to every part of
the vessel to which crew members have
access, (i.e. every cabin, compartment and all
extremes of the deck). Ensure that no alarms
are initiated.
12 V dc
D8989-1
Flash
GREEN
D9034-1
D9035-1
87064_3.book Page 12 Friday, July 28, 2006 9:32 AM