    Installation & operating instructions catalog no. 6000.57g effective: 05-27-10 replaces: 12-12-08 p/n 241086 rev. 8 warning: if these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or death . For your safety: do not store or use gasolin...

  • Page 2

    2 rev. 8 reflects the following: changes to: fig. 2 on page 5, fig. 4 on page 7, fig, 5 on page 8, dimensional drawing on page 13, illustrated parts list on page 15 additions: note on page 4, wiring diagrams on pages 11-12.

  • Page 3

    Warnings 3 pay attention to these terms 3 receiving equipment 4 general specifications 4 installation 4 mounting the assembly 4 wiring a power vent assembly to an appliance with iid ignition 7 venting 7 wiring diagrams 9 182-260 h4/wh1 (atmospheric) 9 181-261 h4/wh1 (low nox) 10 330-400 h4/wh1 (atmo...

  • Page 4

    Receiving equipment on receiving your equipment, check the carton visual- ly for external damage. If the carton is damaged, make a note on the bill of lading when signing for the equip- ment. Remove the complete assembly from the carton if it is damaged, and report the damage to the carrier immediat...

  • Page 5

    5 7. Mount the power vent on the outer top. 8. Route the conduit harness of the power vent thru the outer top hole, around the adapter towards the back of the unit. Continue routing the harness thru the corner slot, which leads to open area behind the access panel. Finally, route only the wire harne...

  • Page 6

    6 u.S. Installations 1 canadian installations 2 a clearance above grade, veranda, porch, deck, or balcony 1 ft (30 cm) 1 ft (30 cm) b clearance to window or door that may be opened 4 ft (1.2m) below or to side of opening; 1 foot (30 cm) above opening 3 ft (91 cm) c clearance to permanently closed wi...

  • Page 7

    7 wiring a power vent assembly to an appliance with iid ignition venting the vent pipe must be the same size or one size larg- er than what is indicated. The d-2 power vent is capable of 360-degree discharge rotation and oper- ates with a positive vent static pressure and with a vent gas temperature...

  • Page 8

    8 left side the d-2 power vent assembly includes a wire harness, shown in fig. 6 below, which provides quick connec- tions with the respective controls in the heater control box. The harness is of sufficient length to fit the appliance for which it is sized. Reference the wiring diagram supplied wit...

  • Page 9

    9 wiring diagrams—182-260 h4/wh1 (atmospheric).

  • Page 10

    10 181-261 h4/wh1 (low nox).

  • Page 11

    11 wiring diagrams—330-400 h4/wh1 (atmospheric).

  • Page 12

    12 331-401 h4/wh1 (low nox).

  • Page 13

    13 d 12.95 c 1.88 4.38 see table d for dimensional data model no. A b c d 181 18.13 12.38 7.88 4.25 182 18.13 12.38 7.88 4.25 260 18.13 12.38 7.88 4.25 261 18.13 12.38 7.88 4.25 330 17.50 15.75 7.63 6.00 331 17.50 15.75 7.63 6.00 400 17.50 15.75 7.63 6.00 401 17.50 15.75 7.63 6.00 table d: dimension...

  • Page 14

    14 sequence of operation on call for heat, the d-2 power vent fan (and appli- ance pump) start. When the flow switch circuits close, the ignition system consisting of an electronic spark module, pilot gas system and flame sensor, are ener- gized. When draft proving switch closes and all safety circu...

  • Page 15

    15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 call out description 181-261 330-401 f 4 8 7 8 0 0 f 4 8 7 8 0 0 y a l e r 1 f 6 5 1 8 0 0 f 6 5 1 8 0 0 r e w o l b 2 3 no pressure switch 008062f 008135f 4 elbow 4"-90° with screen 010827f 010827f f 3 8 6 8 0 0 f 2 8 6 8 0 0 x o b e u l f 5 6 base assembly 00...

  • Page 16: Www.Raypak.Com