3. TYPES OF INSTALLATIONS
INDEPENDENT
SYSTEM
INSTALLATION
This application uses a devoted
duct system for the supply
and the exhausting of stale air
accumulated in the home.
It is recommended to install
fresh air grilles in all bedrooms
and living areas. Exhaust the
stale air from the bathroom,
kitchen and laundry room. (see
figure 3.1)
IMPORTANT:
For optimal
performance of your HRV, the
installation of an optional 6” round
galvanized backdraft damper is
required on the fresh air to home
duct work.
figure 3.1
EXHAUST AT THE
SOURCE AND
SUPPLY IN THE
RETURN
This application uses a devoted
duct system for the exhausting
of stale air accumulated in the
home. The fresh air is dumped
into the return air duct and is
distributed thru the home by
the existing supply air ductwork
of the forced air system. (see
figure 3.2)
Make sure when using this
application that your fresh air
duct connection to the forced air
system return air duct is not less
than 10ft (3 m) upstream of the
return plenum connection to the
forced air system. Check with
your local code or the forced air
system’s manufacturer. The HRV
and forced air system must be
in continuous mode, to achieve
maximum comfort and to avoid
cross-contamination.
NOTE TO INSTALLER:
Dwellings with multiple forced
air systems requires one HRV
per system.
Insure the unit runs in
conjunction with forced air
system (Ref. wiring diagram for
furnace interlock)
figure 3.2
* For minimum distance between return and forced
air system, check with your local building codes
and forced air system manufacturer.
From Bathroom
or Kitchen
To living space
HRV
Forced Air System
6'
(1.83 m)
A
B
18" (457 mm)
A+B=NOT LESS THAN 10FT (3 M)*
IMPORTANT:
The duct bringing outdoor air to the
return air plenum must be equipped with a manual
dumper to balance the outdoor airflow.
IMPORTANT: For optimal performance of your HRV, the installation of an optional 6" round galvanized backdraft
damper is required on the fresh air to home duct work. When performing duct connections, always use approved
tools and material. Also use steel duct connections for these type of installs.