Samsung AC***MNADKH Installation Manual - page 23
23
English
Ins
tallation
Option
SEG13
SEG14
SEG15
SEG16
SEG17
SEG18
Explanation
PAGE
Use of external
control
Setting the output
of external control
S-Plasma ion
Buzzer control
RESERVED
Indication and
details
Indication
Details
Indication
Details
Indication
Details
Indication
Details
Indication
Details
2
0
Disuse
0
Thermo
on
0
Disuse
0
Use
1
On/Off
control
2
Off
control
1
Operation
on
1
Use
1
Disuse
3
Window
on/off
control
Option
SEG19
SEG20
SEG21
SEG22
SEG23
SEG24
Explanation
PAGE
Individual control of
a remote controller
Heating setting
compensation
RESERVED
RESERVED
RESERVED
Indication and
details
Indication
Details
Indication
Details
Indication
Details
3
0 or 1
Indoor 1
0
Disuse
2
Indoor 2
3
Indoor 3
4
Indoor 4
1
2˚C
2
5˚C
If you input a number other than 0~4 on the individual control of the indoor unit(SEG 20), the indoor is set as "Indoor 1".
Example) If you want to set as "Exterior temperature sensor : USE, External control : USE
SEG1
SEG2
SEG3
SEG4
SEG5
SEG6
0
2
-
1
0
-
SEG7
SEG8
SEG9
SEG10
SEG11
SEG12
1
0
-
-
-
0
SEG13
SEG14
SEG15
SEG16
SEG17
SEG18
2
1
0
-
0
0
SEG19
SEG20
SEG21
SEG22
SEG23
SEG24
3
0
-
-
-
-
assign option codes except SEG 1, 7, 13, 19 which are page options.
* Level control : The centralized controller can limit the functions and inputs of connected products with this function
enabled.
[ Example: Operation mode limit (Cooling only/Heating only/No limitation), Heating temperature upper
limit, Cooling temperature lower limit ]
To enable 'Level control' when applying the DPM with the centralized controller, appoint the master
(Set 'Use of external control [SEG14] option to 4 or higher).