Serene Central Alert CA-CX User Manual - page 11
Follow the steps below:
1. Place CA-360 master unit in the clock mode (RUN
position), Press and Hold the SOS / TEST button
for 6 seconds until it beeps. It will display “LEAr”
and ready to learn accessories.
2. Power On the CA-PX.
3. Press and hold the Learn button on the CA-PX for
at least 10 seconds until CA-360 beeps twice, and
the display shows “SUB” - confirming registration is
successful.
4. Press Reset button on both CA-360 unit and
the CA-PX to end the Learn process.
5. Testing the system: Press and Hold the SOS
button on the CA-PX for 2 seconds. This
should activate an alert on both the CA-PX and
CA-360 units. Press the Reset button on either
unit to stop and cancel the alert.
6. Press an accessory (such as a doorbell) that
was previously registered to the CA-360
master unit. Verify that both CA-360 and the
CA-PX alerts are activated for 45 seconds, or
until the Reset button is pressed.
7. The CA-PX is now ready and will alert the user
whenever a wireless signal is detected.
Reminder: All previously learned accessories in
the CA-PX will be lost during the process of
adding the CA-PX into a CA-360 alert system. All
lost CA-PX accessories will need to be learned
again into the system through the CA-360 master
unit.