ServerLink Extend Cat5 Installation Instructions Manual - page 13
11
Button on Local Computer Unit
There are three modes that can be chosen, the sequence is as
follows:
Auto
→
Loc
→
Com(Remote)
Auto:
• In this mode, the Remote and Local LEDs are flashing
alternately.
• The system is now waiting to be controlled by either Local
Computer Unit or Remote Station Unit.
• Once the keyboard or mouse of Local Computer Unit is
active, the LED of Local is on and the LED of Remote is off.
This status indicates that the Local Computer Unit is now
taking control of the system.
• Once the keyboard or mouse of Remote Station Unit is
active, the LED of Remote is on and the LED of Local is off.
This status indicates that the Remote Station Unit is now
taking control of the system.
• In either case, the latch time period of 5, 15, 30, or 60
seconds is offered to allow the Local Computer Unit or
Remote Station Unit to take control again. If the latch time
expires with no keyboard or mouse activity, the status
returns to the “Auto” mode.
• In
“Auto” mode, whenever the keyboard, mouse buttons
or scroll wheel of mouse is activated, the Unit (Local
Computer Unit or Remote Station Unit) immediately takes
control of the system.
Local: The LED of Local is “On”. In this mode, the system is being
controlled by the Local Computer Unit. In this case, the
Remote Station Unit can learn this status from the flashing
of 3 LEDs (Num, Caps and Scroll Lock) on the keyboard.
Remote: The LED of Remote is “On”. In this mode, the system is
remotely controlled by the Remote Station Unit.