Smartload DEGX1 User Manual - Fault Code 22

Summary of DEGX1

  • Page 1

    Dryer models degx1 and dggx1 517772 fisher & paykel appliances © 2004 august 2004.

  • Page 2: Specifications

    2 specifications operating voltage maximum current usa electric 220/240v ac 60hz 24 amps usa gas 110/120v ac 60hz 6 amps igniter gas cold resistance 40 - 200 ohms typical temperature 2399°f (1315°c) @ 120v minimum temperature 1805°f (985°c) @ 80v maximum temperature 3092°f (1700°c) @ 132v valve regu...

  • Page 3: Element Assembly 240V 1.4Kw

    3 element assembly 240 v 3.6 kw two sets of nichrome wire elements linked in parallel between mica plates. A ceramic insulator is used to support the element assembly in the housing. Resistance 13.5 ohms current 15 amps power 3.6 kw voltage 240 volts (between two phases) element assembly 240v 1.4kw ...

  • Page 4: Lid Lock

    4 lid lock resistance range 63 ohms +/- 10 ohms @ 68°f (20°c) safety extra low voltage. Temperatures each cycle, denim through to delicate, has a temperature limit, as defined in the table below, as measured in the exhaust air. After switching off at the limit, the temperature has a hysteresis of 5 ...

  • Page 5: Diagnostics

    5 diagnostics overview if a fault occurs that prevents correct operation of the dryer, and is detected by the controllers, the dryer is stopped, the display shows a fault code and the beeper is continuously turned on and off. Pressing the power button will stop the beeper but leave the fault code di...

  • Page 6: Entering The Showroom Mode

    6 conductivity contact impedance check to enter the conductivity contact impedance check, enter the diagnostic mode as described above, then press the auto dry up button five times. In this mode, touching damp clothes or fingers across the conductivity contacts will cause the led display to change. ...

  • Page 7: Fault Codes

    7 fault codes the fault code is displayed in the l.E.D.S of the drying progress display portion of the display panel as shown below. Each l.E.D. Illuminated represents a binary code. By adding up the binary code value of the l.E.D.S that are illuminated, the fault code number can be determined. In t...

  • Page 8: Detailed Fault Codes

    8 detailed fault codes the following are the fault codes that may be displayed. The remedy section of each fault is the suggested sequence of repair or replacement. If the first suggestion does not remedy the fault, check the next on the list. Fault code 1 communications error. Communications failur...

  • Page 9: Fault Code 3

    9 fault code 3 drum stalled. Remedy: (1) if there is mechanical movement of the drum, but this fault code is appearing, follow the procedures for fault code 2. (2) if there is no mechanical movement of the drum, check drum movement mechanisms: belt, motor and motor harness. (3) replace the motor con...

  • Page 10: Fault Code 7

    10 fault code 7 motor current excessive. Remedy: (1) free up the dryer. Remove overload or cause of jamming. (2) replace the motor control module. (3) replace the motor. Fault code 8 exhaust sensor over temperature. The exhaust sensor measures over temperature (fire detection, element short circuit ...

  • Page 11: Fault Code 10

    11 fault code 10 24 volt supply measurement error. The sensor module measures low voltage on actuator power supply. Remedy: replace the sensor module. Fault code 11 lid lock open circuit. Remedy: check the lid lock harness and coil. If there is continuity through these, replace the sensor module. Fa...

  • Page 12: Fault Code 15

    12 fault code 15 sensor module fault. Remedy: replace the sensor module. Fault code 16 airflow restriction - user warning. Airflow restriction. Remedy: (1) check that the lint bucket is empty and the filter is clear. (2) ensure that the exhaust duct is not restricted, blocked or kinked, preventing g...

  • Page 13

    13 fault code 21 door actuator required excess voltage. Remedy: (1) ensure there is no weight placed on the lid of the product (e.G. Clothes basket). If so, remove the weight and retest. (2) inspect the installation, making sure that the cabinet sits evenly on the floor. If excess load is placed on ...

  • Page 14: Fault Code 22

    14 fault code 22 door actuator open circuit. Remedy: (1) check that the actuator wiring is plugged into the sensor module and is not open circuit. If faulty, replace. (2) replace the sensor module. Fault code 23 door actuator movement interrupted by low voltage. The door actuator movement was interr...

  • Page 15: Fault Code 28

    15 fault code 28 data retrieval error following loss of power remedy: (1) switch off the mains power supply to the dryer for at least 10 seconds and confirm error. (2) replace the motor control module. Fault code 29 brown-out data retrieval error. Remedy: (1) if the fault occurs every time the dryer...