Smartload DEGX1 User Manual - Entering The Showroom Mode
6
Conductivity Contact Impedance Check
To enter the conductivity contact impedance check, enter the diagnostic mode
as described above, then press the Auto Dry up button five times. In this
mode, touching damp clothes or fingers across the conductivity contacts will
cause the LED display to change. If the contacts, or the harness to them,
have gone open circuit, no change will occur in the LED display. This is a
useful method of checking the integrity of the sensor circuits.
To exit the diagnostic mode, press any cycle button.
Entering the Data Download Mode
(a) Turn the power supply to the dryer on.
(b) Press and hold the Auto Dry down button, then press the Power
button. This enters the diagnostic mode.
(c) Press the Regular button.
Encoded data is transmitted serially out the red Auto LED, and is be captured
by an optical download pen attached to a PC where “Smart Tool” software
interprets the data to aid servicing.
To exit, press the Regular button.
Entering the Showroom Mode
(a) Turn the power supply to the dryer on.
(b) Press and hold the Air Dry button, then press the Power button.
The LEDs will flash in a random sequence.
To exit, turn off the power supply to the dryer at the wall.