Smartload DEGX1 User Manual - Fault Codes
7
Fault Codes
The fault code is displayed in the L.E.D.s of the Drying Progress display
portion of the display panel as shown below.
Each L.E.D. illuminated represents a binary code. By adding up the binary
code value of the L.E.D.s that are illuminated, the fault code number can be
determined.
In the example above the fault code is 8+2+1 = 11
User Warnings
In the case of user warnings, the dryer may either pause, or “limp on”, and
flash an LED (see Detailed Fault Codes, page 8) at the same time as
sounding a user warning. Pressing any button will stop the sound, and
pressing the Start or Power buttons, or the completion of the cycle, will stop
the display of the warning. The warnings are stored as “faults” in memory
with their warning or fault numbers, and can be recalled as “last fault” on the
display, or by downloading the information using the Fisher & Paykel Smart
Tool diagnostic software.
Note: The blue Cool Down L.E.D. illuminated without the fault “beeps”
indicates the dryer is in a low mains voltage (brown out) state, and is
momentarily displayed whenever the supply power is turned off.