SPX 3641 User Manual - Software Update
5
Software Update
The battery charger and analyzer operating software is
easily updated with upgraded programs supplied on
Compact Flash cards.
To update battery charger and analyzer software with
the Compact Flash card, follow these steps:
1. Turn OFF the battery charger and analyzer. Insert the
Upgrade Software Compact Flash card into the Compact
Flash Card port.
Compact Flash Card port
Figure: Compact Flash Card port
2. Turn ON the battery charger and analyzer. Press the
MENU button. Press
Button 4 to select Update S/W
(Software). Press Button 1 to begin the update.
3. Press GO, the installation will be completed in two or
three minutes.
4. When the installation is completed, turn OFF the battery
charger and analyzer and remove the Compact Flash
card from the Compact Flash Card port. Restart the
battery charger and analyzer to complete the update
process.
•
Do not spray excessive liquids on the battery
charger and analyzer case, they may enter the case
and cause permanent damage to the electrical
components. Flammable liquids may cause an
explosion.
•
When plugging the power cord into an electrical
outlet, avoid wet floors to prevent electrical shock.
•
Immediately replace the battery charger and analyzer
cable if it is worn or damaged.
Clean the outside of the case and the cables with a mild,
multipurpose cleaner. Do not allow excessive moisture to
seep into the case. While cleaning the cables, inspect for
damage and replace as necessary.
IMPORTANT:
Do not use solvents or harsh cleaners on the cables,
the chemicals will eventually dry them out and they will
crack.
Keep the cable clamp ends clean. Use a small wire brush if
necessary.
User-Serviceable Components
Warning:
There are no user-serviceable components located
on the inside of the tester: all servicing should be
performed by qualified service personnel.
Unit Relocation
The battery charger and analyzer is not intended to be
removed from the stand or used as a portable unit. If
relocation or replacement is necessary, a minimum of two
persons are required to lift and move the unit.
Maintenance
Instructions
To clean the outside surface of the battery charger and
analyzer, follow these precautions and steps:
Warning:
•
Unplug the battery charger and analyzer from the
electrical supply before performing maintenance.