  • Page 1

    Svs 12hse lift installation instructions (220v) svs, inc. Lifting your image 2513 jenks ave panama city, fl 32405 www.Svslifts.Com tel: 850-522-4747 fax:850-522-4739 sales@svslifts.Com international sales tel: 001-720-283-6410 fax:001-720-283-6424 svs 12hse lift installation instructions page 1 of 1...

  • Page 2

    Svs 12hse lift installation instructions sections: page 1. General description.................................................................................................................................3 2. Features & specifications..................................................................

  • Page 3: Svs 12Hse Lift

    Svs 12hse lift 1. General description: the svs 12hse series lift support large projectors (up to 32.5" [82.5cm] wide) that require additional size and weight accommodations. It features the “longest” lowering distances from 24-feet 9-inches (7.59m) to 33-feet 8-inches (10.3m). This model is supplied...

  • Page 4

    3. Svs 12hse lift warranty svs, inc. 's limited warranty only covers failures due to defects in materials or workmanship that occur during normal use. This limited warranty does not cover failures resulting from accident, misuse, abuse, neglect, mishandling, misapplication, faulty or improper instal...

  • Page 5

    Important: please read through all instructions before beginning your installation. This lift is designed to be used with a wall plate controller, either automatically or manually controlled and will function without any special training in the “show” mode. The wall plate controller features a key s...

  • Page 6

    5. Consideration for lift placement • before beginning the installation, check the dimensions of the lift against the available space above the ceiling. Be sure to include the projector lens and any accessories which may add to the overall dimensions • preliminary measurements should also be made to...

  • Page 7

    If the ceiling clearance allows, an “x-y” or a cross-supporting structure is strongly suggested as shown in figure 6 recommended lift support structure for flat ceilings. This allows for front-to-back and side-to-side adjustments of the lift for alignment to the screen. Svs 12hse lift installation i...

  • Page 8

    Important when attaching the lift to a flat concrete ceiling, svs suggest two (2) pieces of p1000t unistrut (or equivalent) approx. 10-feet (3.04 m) long, to be installed on the ceiling first. Proper spacing between the two pieces will be based on the distance between the four (4) mounting holes of ...

  • Page 9

    1. Raise the lift into the ceiling and line up the six (6) mounting holes in the lift's top frame with the 1/2” threaded rods of the supporting structure. Make sure that there is a top nut and a flat washer on each threaded rod before the lift is mounted. See figure 6. (plenum shrouds require additi...

  • Page 10

    Electrical connections should be made at this time. The svs 12hse requires 220v/50hz at 1.2 amps and is supplied with a six foot power cord. The svs 7 lift is controlled with a 24vac low voltage controller called the wall plate controller. This controller can easily be connected to external controll...

  • Page 11

    B. Connecting a touch screen controller (external controller) the simplest external controller connections are to use the white wire (pin 1) as the common and the black (pin 3) for down to show position and the red wire (pin 2) for up. For this and other wiring options please refer to the external c...

  • Page 12

    Cable management is used to keep projectors cables away from the scissors during lift operation. Do not attach the projector cables to the scissors of the lift as they could be repeatedly pinched when the lift raises and lowers. See figure 11. Dual accessory #7 cable retractor are standard equipment...

  • Page 13

    Excess slack can be removed by adjusting the cable clamping on the cable reel after tracking the lift up & down. If the slack is adjusted correctly, the cable will be more even when in the up and down positions, with slack occurring only in the middle position. 10. When proper cable tension is achie...

  • Page 14

    A. Maintenance • inspect the lift occasionally for any loose bolts or cable clamps. The scissor bolts are adjusted for no slack, but must not be too tight. If scissor bolts are found loose, tighten to approximately 151 lbs torque, the back off 1/8-inch. These bolts have nylon locking nuts and should...

  • Page 15

    14. Troubleshooting all svs lifts are quality checked before they leave the svs factory and are fully operational. Shipping damage and installation oversights can cause problems to appear. Here are a few common and simple things to check. If at anytime you are unsure of the check, please contact svs...

  • Page 16

    Drum lock solenoid disconnect one of the solenoid wires and measure the resistance across the black and green wire. If the resistance is less than 9.5 ohms replace the solenoid. Lift works with the key switch in the service position but will not lower in the show position the show position microswit...