SVT Innovations SVT-2 User Manual - Parts and Functions:
Parts and Functions:
The SVT-2 Outdoor Station A is audio outdoor station with external camera suitable for any angle
mount. The front panel is made of zinc alloy for better protection against vandalism &
cauterization. The call button is also made of zinc alloy and it has a blue backlight for auxiliary
illumination. The Rain Guard offers an extra protection to the outdoor stations.
◆
Lock Control Jumper:to select the lock type. Please refer to Electric Lock Connection
◆
DIP switch: to set ID code for outdoor station. It expands to a maximum of 4 outdoor
stations. For additional information, refer to DIP Switches Settings.
◆
SPK adjust: to adjust the talk volume.
◆
PROG button: function reserved.
◆
CALL button: press to call the user.
◆
4 P terminal: function reserved.
◆
Connection line: to connect the bus line and tdoor locks.
BUS(Blue&Green): connect to the bus line, non polarity.
S2+(Red): the S2+ connect with S1- to activate the relay of SVT-2 ERL to install the
external camera SVT-2 AC31. Refer to the SVT-2 AC31 User Manual for additional
instructions.
PL(White): external lock power input, connect to the power positive(power +). S1+(Yellow):
lock power(+) output.
S1-(Black): lock power(-) output.
Unit Mounting
The location of outdoor station should keep away from snow,rain,and intensity light.
Accessory contents:
Accessories include a screwdriver T20, one M4X10 screw, two PA4X25 screws,three PA3x25
screws,three PM3x12 screws,and five screw stoppers Φ6X30.
Installation steps:
Installation height for door station usually is 145~160cm.
1. Use screws to fix the back panel and rainy cover to the wall after connect the cable correctly.
2. Attach the front panel to the back panel, then use the screw to fix it.
Wiring and Connection
Basic one-to-one connection
Terminal Description:
Speaker
Talk Indicator
Unlock Indicator
Call Button
Front Panel
Microphone
1
2
3
4
7
5
6
1
2
3
4
5
6
Rainy Cover
7
M4*10
PM3*12
1
2
3
-
+
Monitor
Bus PL S2+ S1+ S1-
BUS(Blue&Green);
S2+(Red); PL(White); S1+(Yellow); S1-(Black);
AC~
PC6
1 2 3
ON
1 2 3
1 2 3
ON
1 2 3
BUS(Blue&Green)
S2+(Red)
PL(White)
S1+(Yellow)
S1-(Black)
4P
terminal
DIP
PROG
SPK adjust
Lock Control
Jumper
Connection line
CALL button
please refer to DT-CAM user instructions in details.
PL(White): external lock power input, connect to the power positive(power +).
S1+(Yellow): lock power(+) output.
S1-(Black): lock power(-) output.
-3-