SVT Innovations SVT-2 User Manual - page 8
With DT-CAM wiring mode
Electric Lock Connection
Door Lock Controlled with Internal Power
Door Lock Controlled with Dry Contact
Note:
1. Electronic lock of Power-on-to-unlock type
should be used.
2. The door lock is limited to 12V, and holding
current must be less than 250mA.
3. The door lock control is not timed from Exit
Button(EB).
4. The Unlock Mode Parameter of Monitor must
be set to 0 (by default).
EB
*
LOCK
Jumper position in
Connect one lock
2-3
Bus PL S2+ S1+ S1-
Note:
1. The external power supply must be used
according to the lock.
2. The jumper must be taken off before connecting.
3. Setup the Unlock Mode of Monitor for different
lock types.
* Power-on-to-unlock type:Unlock Mode=0 (by default)
* Power-off-to-unlock type:Unlock Mode=1
The audio door station DT595A can be extended an additional CCTV camera to be a video door
station. For more details about the camera, please refer to DT-CAM user instructions.
LOCK
Take off the Jumper
POWER
SUPPLY
Bus PL S2+ S1+ S1-
1 2 3
AC~
PC6
ERL
DT595A
DT-CAM
DS
IM
Bus PL S2+ S1+ S1-
OUT IN
Monitor
-8-
Door Lock Controlled with Dry Contact
Note:
1. The external power supply must be used
according to the lock.
2. The jumper must be taken off before connecting.
3.. Setup the Unlock Mode of Monitor for d ferent
lock types.
*
*
Power-on-to-unlock type:Unlock Mode=0 (by default
Power-o f-to-unlock type:Unlock Mode=1
LOCK
POWER
SUPPLY
Take off the Jumper
Bus PL S2+ S1+ S1-