Takex OMS-12FE Instruction Manual

Manual is about: Dual Zone Outdoor PIR

Summary of OMS-12FE

  • Page 1

    ① we appreciate your purchase of a takex passive infrared sensor. This sensor will provide long and dependable service when properly installed. Please read this instruction manual carefully for correct and effective use. Please note : this sensor is designed to detect intrusion and to initiate an al...

  • Page 2: Parts Description

    Parts description 1 precautions 2 ② warning caution this mark indicates details regarding handling which, if ignored, may result in death or injury. This mark indicates points of which the user should be aware. This mark indicates a prohibition, with the item shown in the mark specifically prohibite...

  • Page 3

    Not detected 40'(12m) detected range in which people are detected range in which cars are detected detected ③ → [8 operation confirmation] *adjust the area and set detection distance in order that other than the desired objects are not detected. S if there is a road at the edge of the detection area...

  • Page 4: Detection Area

    ④ detection area 3 index holder locking screw mark mark closer distance detection further distance detection please refer to 3-2 area adjustment. → [7-1 removing the cover] 3-1 3-2 [side view] the sensor has two areas, right and left, and each area has two zones of detection — the horizontal zone an...

  • Page 5: 3-3

    ⑤ the cut sections of the area masking sheet are the areas that are detected. Once the sheet has been cut, it cannot be restored, therefore take care when cutting. When masking an area to one side (left or right areas), ensure that 2 masking sheets are attached to the corresponting portion of the le...

  • Page 6: Function

    Function 4 ⑥ (cover tamper) back tamper knockout back tamper rubber after turning the power on, the operation led will blink for approximately 1 minute. During this time, the device is stabilizing, and will not operate. If the cover is removed, or if it is incorrectly mounted, a tamper alarm is outp...

  • Page 7: Setting

    Setting 5 ⑦ regardless of the settings of switch 6, the sensor will cover a 180° detection area. Use 180° area [factory set] the right area is disabled. The left area is disabled. Use left 90° area use right 90° area on 1 2 3 4 5 6 7 8 on 1 2 3 4 5 6 7 8 on 1 2 3 4 5 6 7 8 off off off right side rig...

  • Page 8: Wiring

    Wiring 6 ⑧ after wiring the terminal board, wind any remaining wires into the wiring space within the sensor. A gap remains after feeding the wiring through the wiring hole, therefore use sealant to caulk this gap in order to prevent the entry of insects, and to ensure waterproofing. S for solid wir...

  • Page 9: Installation

    Installation 7 walk test (operation confirmation) 8 ⑨ ensure that the sensor is not at an angle when viewed from the front. Ensure that the sensor is not at an angle when viewed from the front or side. As necessary, use sealant to caulk around the screws or gaps between the sensor body and the mount...

  • Page 10: Troubleshooting

    Troubleshooting 9 ⑩ periodic checks solve possible problems according to the following table. If normal operations cannot be restored by this means, contact either the dealer from whom you bought the unit or takex. 1. When cleaning, after wiping with a damp soft cloth, wipe off water droplets. If ve...

  • Page 11: Specifications

    Specifications 10 ⑪ (wall mount ) supply voltage model detection system coverage coverage adjustment current consumption alarm output tamper output operation led counts selectable switch passive infrared when horizontal detection angle : 180 ° detection distance : 40' (12m) horizontal zone : 14zones...

  • Page 12: External Dimensions

    External dimensions 11 ⑫ scale :free unit :inch(mm) no.05-683 1201 in japan takex america inc. Unit 16/35 garden road, clayton, 3168 victoria, australia tel : 03-9546-0533 fax : 03-9547-9450 takenaka engineering co., ltd. 83-1, gojo-sotokan, higashino, yamashina-ku, kyoto 607-8156, japan tel : 81-75...