Takex OMS-12FE Instruction Manual - Installation
INSTALLATION
7
WALK TEST
(OPERATION CONFIRMATION)
8
⑨
Ensure that the sensor is not at an angle when
viewed from the front.
Ensure that the sensor is not at an angle when
viewed from the front or side.
As necessary, use sealant to caulk around the screws or gaps
between the sensor body and the mounting surface in order
to protect against insects, and to ensure waterproofing.
Ensure that sealant is used to caulk wiring hole and
gaps in order to protect against insects, and to ensure
waterproofing.
(1) Loosen the cover locking screws, and remove the cover.
(1) Remove the pole mounting bracket knockouts (4 locations).
(2) Secure the optional pole mounting bracket to the sensor
using screws.
[Supported pole diameter of 1.50" to 1.77" (38mm to 45mm)]
Remove the wall-mounting knockout, and fix the sensor to
the wall using the included screws.
Wall mounting screws (4mm×35mm): ×2
Mounting pitch: 7.56" (197mm)
Pole mounting bracket: ×2
Pole mounting bracket screws: ×4
(3) Place the optional fixing bracket around the pole, and fix
the sensor to the pole with the pole bracket and screws.
Fixing bracket: ×2
Fixing bracket mounting screws (M4×40mm): ×4
(2) Carry out wiring work.
For wall mounting
7-1
Removing the Cover
7-2
Installation Method
→
「6 WIRING」
(1) Set the operation LED ON.
(2) Attach the cover to the sensor body, turn on the power, and wait approximately 1 minute for the operation LED to stop
blinking.
(3) Walk across the detection area, and confirm the area positioning and distance by the operation LED. (The operation LED
lights when an alarm is initiated.)
(4) Change the detection area distance, masking, sensitivity, and pulse count settings as necessary.
(5) Confirm operation of connected devices if there are.
For pole mounting
→ [2 PRECAUTIONS]
→ [3 DETECTION AREA]
Select a mounting location that matches the intended purpose.
Using the pole attachment : BP-32 (Sold Separately)
→ [3 DETECTION AREA]
→ [4 FUNCTION]
→ [5 SETTING]
Cover locking screw
7.56'
(197mm)