Takex OMS-12FE Instruction Manual - Specifications
SPECIFICATIONS
10
⑪
(Wall Mount
)
Supply voltage
Model
Detection system
Coverage
Coverage
adjustment
Current consumption
Alarm output
Tamper output
Operation LED
Counts selectable switch
Passive infrared
When horizontal detection
Angle : 180
°
Detection distance : 40' (12m)
Horizontal zone : 14zones
Downward zone : 14zones
OMS-12FE
Horizontal : L/R
90°(selectable)
Detection distance : 10'
〜40' (3m〜12m)
(By adjusting vertical angle of downward curtain)
9 to 28V DC (non-polarity)
20mA MAX.
Dry contact relay output N.C./N.O. selectable
*Contact capacity : 30V (AC/DC), 0.2A MAX.
(Resistive load)
*Contact operation : Detection time(2sec)
Dry contact relay output N/C
*Contact capacity : 30V (AC/DC), 0.1A MAX.
(Resistive load)
Red LED
Blinking at warming up
Lighting at alarm (LED disabled)
*Approx. 30% -Approx. 170% (By Potentiometer)
1/2/3/4 times (with a switch)
Indoor / Outdoor
Body : AES resin Lens : PE resin
Terminals
IP 54
(equivalent)
−4°
F to
+ 122°
F (
−20℃ to + 50℃)
16.5oz (470g)
Sensitivity adjustment
Connection
Ambient temperature
Mounting position
Ingress protection
Weight
Appearance
Optional
Pole attachment : BP-32