Figure 5 shows step 5 in the description:
Rack mounting kit mounted in rack with
one screw M6x12 in upper hole on both
left and right side.
On the rear side two screws must be
used on both left and right side.
Totally six screws are used to install the
“rack mounting kit” to the rack.
Figure 5. Rack mounting kit mounted
in rack
Mounting the StorageLoader to the Rack
Make sure that all the screws in the Rack Mounting Kit are tightened properly
before installing the StorageLoader in the rack.
Slide the StorageLoader on the rails from the front of the rack, as shown in figure 6.
Then fix the StorageLoader using one M6x12 screw in front of the rack on both left
and right side (see figure 7) and one M5x8 on the backside of the Rack Mounting
Kit on both left and right side (see figure 8).
Figure 6. Slide the StorageLoader in
from the front
Figure 7. Fasten the front of the
StorageLoader to the rack
StorageLoader Quick Installation Guide