TANDBERG Maestro MXP User Manual

Other manuals for Maestro MXP: User Manual, User Manual, Installation Sheet, User Manual
Manual is about: Precision HD Camera

Summary of Maestro MXP

  • Page 1

    User manual software version f4 d13358.06 march 2006 this document is not to be reproduced in whole or in part without permission in writing from:.

  • Page 2: Trademarks and Copyright

    Tandberg maestro mxp ii trademarks and copyright all rights reserved. This document contains information that is proprietary to tandberg. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, electronically, mechanically, by photoc...

  • Page 3

    User manual iii ecos ecos, the embedded configurable operating system. Copyright (c) 1998, 1999, 2000, 2001, 2002, 2003 red hat, inc. Copyright (c) 2002, 2003 john dallaway copyright (c) 2002, 2003 nick garnett copyright (c) 2002, 2003 jonathan larmour copyright (c) 2002, 2003 andrew lunn copyright ...

  • Page 4

    Tandberg maestro mxp iv disclaimer the information in this document is furnished for informational purposes only, is subject to change without prior notice, and should not be construed as a commitment by tandberg. The information in this document is believed to be accurate and reliable; however tand...

  • Page 5: Environmental Issues

    User manual v environmental issues tandberg visual communication products significantly reduce the need for travel and thereby help reduce various types of pollution. Tandberg recommends the use of low energy peripherals, such as energystar™ monitors. Thank you for buying a tandberg product. Battery...

  • Page 6: Operator Safety Summary

    Tandberg maestro mxp vi operator safety summary for your protection, please read these safety instructions completely before operating the equipment and keep this manual for future reference. The information in this summary is intended for operators. Carefully observe all warnings, precautions and i...

  • Page 7

    User manual vii ƒ isdn cables - caution - to reduce the risk of fire, use only no. 26 awg or larger telecommunication line cord. ƒ servicing - do not attempt to service the apparatus yourself as opening or removing covers may expose you to dangerous voltages or other hazards, and will void the warra...

  • Page 8: Contact Us

    Tandberg maestro mxp viii contact us if you have any questions, comments or suggestions, please see the online support section at www.Tandberg.Net . It is also possible to send a fax or mail to the attention of: product and sales support tandberg p.O. Box 92 1325 lysaker norway tel: +47 67 125 125 f...

  • Page 9: Table of Contents

    User manual ix table of contents 1 introduction............................................................................................................................. 13 1.1 at a glance ...............................................................................................................

  • Page 10

    Tandberg maestro mxp x 3.11.7 display snapshot ..................................................................................................... 90 3.12 conference services.......................................................................................................... 91 3.12.1 request...

  • Page 11

    User manual xi 4.3.9 vnc settings ......................................................................................................... 163 4.4 call quality......................................................................................................................... 164 4.4.1 video al...

  • Page 12

    Tandberg maestro mxp xii 6.5 appendix 5 ......................................................................................................................... 270 6.6 appendix 6 ..........................................................................................................................

  • Page 13: 1 Introduction

    1 introduction the tandberg maestro mxp provides high-end performance features, large monitors and precision audio. This creates a collaborative meeting environment for medium to large-sized meeting rooms. Audio quality high-performance audio provides a richer, more complete visual communication exp...

  • Page 14

    Tandberg maestro mxp 14 security secure conference tf provides embedded encryption for both point-to-point and multisite call and ensures both privacy and security. The system is delivered with integrated expressway™ firewall traversal technology. When used together with a tandberg border controller...

  • Page 15

    Installation 15 users can display video and presentations in the best layout based on the situation. Supported screen layouts are: ƒ picture in picture (pip) ƒ picture outside picture (pop) ƒ side by side user interfaces a web-interface to the codec provides: ƒ system management, diagnostics and sof...

  • Page 16: 1.1 At A Glance

    Tandberg maestro mxp 16 1.1 at a glance wave ii camera the main camera is mounted on top of the product. The main camera includes a high quality color camera with a fast pan/tilt/zoom action. The main camera is controlled by the system’s infrared remote control and operates pan/tilt, focus and zoom....

  • Page 17

    Installation 17 internal lcd display the system has a built-in 5inch lcd designed to optimize system configuration and give the user access to menus and test video signals without attaching or powering an external display device. The lcd gives full control of all system settings and status. Below th...

  • Page 18

    Tandberg maestro mxp 18 the reach of the remote control signal is 20 meters. For users sitting in an open plan office, this can cause problems. Use the little, white switch placed under the batteries to change the reach of the signal from 20 meters to 2 meters. This will prevent you from unintention...

  • Page 19

    Installation 19 tandberg tracker the tracker is a small infrared remote control device made to steer the camera to any desired location within the room. Typically, several trackers would be used with each system. Each tracker has two buttons: ƒ one single person button to point the camera at a speci...

  • Page 20: 1.2 Menu Structure

    Tandberg maestro mxp 20 1.2 menu structure the menu structure is divided into two parts. The main menu is available for all users and contains all the functionality of the system. The administrator menu contains all the settings of the system. The administrator settings are accessible from the main ...

  • Page 21

    Installation 21 note that the system features and menu settings may vary depending on network selection and software package..

  • Page 22: 2 Installation

    Tandberg maestro mxp 22 2 installation precautions: ƒ never install communication wiring during a lightning storm. ƒ never install jacks for communication cables in wet locations unless the jack is specifically designed for wet locations. ƒ never touch uninstalled communication wires or terminals un...

  • Page 23: 2.1 Unpacking and Mounting

    Installation 23 2.1 unpacking and mounting 1 unpacking the tandberg maestro is delivered in one transport case with all components inside. Remove the case in the order shown on figure 1. Figure 1 the accessories box contains: ƒ wave ii camera ƒ 2x table microphones ƒ remote control and tracker with ...

  • Page 24

    Tandberg maestro mxp 24 figure 3.

  • Page 25: 2.2 Connecting Cables

    Installation 25 2.2 connecting cables 1. Power cable find the right power cable that works for your country in the accessories box, and connect to power cable from base, and to an electrical distribution socket. 2. Microphone cable connect the microphone cable to the microphone. 3. A) isdn bri conne...

  • Page 26

    Tandberg maestro mxp 26 6. Pc connect cable from dvi-i in pc from the codec to pc..

  • Page 27: 2.3 Monitor Configuration

    Installation 27 2.3 monitor configuration configuration of external display (projector) ƒ select 16:9 or 4:3 format on the projector. ƒ make sure that the main projector is connected to the dvi-i single output on the codec. Please refer to the projector user manual for further information..

  • Page 28: 2.4 System Configuration

    Tandberg maestro mxp 28 2.4 system configuration the system must be configured for each installation. Configuration settings can be made via the system menu. If an external imux or non-standard network is being used it may be necessary to configure any associated external equipment. Navigate through...

  • Page 29

    Installation 29 5. Screen settings when using wide screen (16:9) monitors, set tv monitor format to wide (16:9). Tandberg also recommends setting picture layout to picture outside picture when using 16:9 monitors. Picture outside picture provides a display layout optimized for wide screen monitors. ...

  • Page 30

    Tandberg maestro mxp 30 4. Network profiles please refer to network profiles for details 5. Data port please refer to data port for details 6. Save changes remember to save any changes made in the menu by selecting the save button on the menu line and pressing ok. * the international name field is o...

  • Page 31: 3 General Use

    3 general use wake up the system when the system is not in use, it is in standby mode and the screens are black. Wake up the system by picking up the remote control. An incoming call or pressing any key on the remote control will also wake up the system. If the system does not respond: ƒ make sure t...

  • Page 32: 3.1 The Welcome Screen

    Tandberg maestro mxp 32 3.1 the welcome screen when the system is switched on, the welcome screen will be displayed. The welcome screen presents the menu and displays your main camera image in the background (display main camera is the default setting). The isdn/ip numbers and the system name are di...

  • Page 33: 3.2 Using The Remote Control

    General use 33 3.2 using the remote control the system is controlled with a remote control. Think of the remote control as a mobile phone with number keys and call keys. Use the arrow keys and press ok to navigate through the menus. The system’s most commonly used functions are also accessible direc...

  • Page 34

    Tandberg maestro mxp 34 11. Use zoom + and – to zoom the camera in and out.* 12. Selfview displays your outgoing video. Press selfview again to turn selfview off, see selfview . 13. Use the phone book to store and recall video contacts for easy placement of calls, see phone book . 14. Use the red en...

  • Page 35

    General use 35 the remote control (trc 4)**: 1. Change video source. If possible, you will start open a dual stream. Press the video source button again to stop the dual stream. 2. Mic off turns your microphone on and off, see mic off . 3. Arrow keys are used for navigation in the menu and for movin...

  • Page 36

    Tandberg maestro mxp 36 presentation source. If the presentation key is held down for 1 second then the presentation video sources menu will appear, see presentation key . 12. Press ok/menu to show the menu and to select menu items, see navigation . 13. Use zoom + and – to zoom the camera in and out...

  • Page 37: 3.2.1 Navigation

    General use 37 3.2.1 navigation arrow keys and ok navigate in the menu with the arrow keys on the remote control. The orange selector on screen shows the selected item. Press ok to select. Cancel key in the main menu, pressing cancel (x) will hide the menu. If the menu is hidden, bring it back with ...

  • Page 38: 3.2.2

    Tandberg maestro mxp 38 3.2.2 selfview the term “selfview” means the outgoing image. In a normal call using the main camera, this is the image of yourself. The selfview button toggles the images between far end, selfview and dual video (if any). How to use selfview: 1. Outside a call, pressing the s...

  • Page 39

    General use 39 example: you are using the system as a pc and get an incoming call. When the setting “use screen as local pc monitor” is on, you will keep your pc image displayed locally and the incoming call pops up in a pip or as smaller images in a 1+3 layout, depending on your system. You will se...

  • Page 40: 3.2.3

    Tandberg maestro mxp 40 3.2.3 layout the layout of the screen can either be shown as picture in picture (pip) or picture outside picture (pop) when displaying more than one video image. The behavior of the layout button is dependent on the picture layout setting in screen settings . 3.2.3.1 picture ...

  • Page 41: 3.2.4

    General use 41 3.2.4 mic off to mute the microphone during a call, press the mic off button. An on-screen indicator appears in the upper right corner when the microphone is off. In a call, if audio is detected, the on-screen symbol will start to flash. Pressing the mic off button one more time will ...

  • Page 42: 3.2.5

    Tandberg maestro mxp 42 3.2.5 volume + and - press the volume key to adjust the volume level. An on-screen indicator will show the current level..

  • Page 43: 3.2.6

    General use 43 3.2.6 number and letter keys pressing a number key when outside a call will bring up the call menu. When in a call, the number keys are used for camera presets. Press a number and go to the corresponding camera preset (see camera presets ). However, when accessing an input field where...

  • Page 44: 3.2.7

    Tandberg maestro mxp 44 3.2.7 touch tones to activate dialing touch tones during a call, press the touch tones button. Otherwise the number keys will activate the corresponding camera presets. An indicator will let you know that touch tones are enabled. Finish with ok to exit touch tone mode..

  • Page 45: 3.3 On-Screen Indicators

    General use 45 3.3 on-screen indicators the system has a number of icons signaling different settings: microphone off this indicator is shown when the microphone is turned off. Press the mic off button again to turn the microphone back on, see mic off for details. Volume off this indicator is shown ...

  • Page 46

    Tandberg maestro mxp 46 telephone this indicates that there is a telephone participant in the conference. The displayed number indicates how many telephone participants there are in the conference..

  • Page 47: 3.4 Using The Menu

    General use 47 3.4 using the menu main menu outside a call and in a call. Press the menu button on the remote control to display the menu. The menu contains all functions needed in order to control the system..

  • Page 48

    Tandberg maestro mxp 48 the menu contains the following items: make a call / add another call standby / end call camera control presentation conference services control panel ƒ close see menu structure for a full overview of the menu. The functions of the menu are displayed as icons. The currently s...

  • Page 49: 3.5 Make A Call

    General use 49 3.5 make a call display the call menu by either: 1. Select make a call from the menu, or 2. Press the green call button on the remote control the tandberg system can make both video calls and telephone calls . Call settings specifies the quality of the call. It is possible to alter th...

  • Page 50: 3.5.1

    Tandberg maestro mxp 50 3.5.1 place video call in the make a call menu, enter the dial number either: 1. Manually, or 2. Select the book symbol in order to display the phone book and select a conference participant. When dialing manually, toggle between abc/abc by pressing the # button on the remote...

  • Page 51: 3.5.2

    General use 51 3.5.2 place telephone call in the make a call menu, enter the dial number either: 1. Manually, or 2. Select the book symbol in order to display the phone book and select a conference participant, see phone book for details. When entering a dial number manually, toggle between abc/123 ...

  • Page 52: 3.5.3

    Tandberg maestro mxp 52 3.5.3 add call (optional feature) conference systems with built-in multisite can handle up to 6 video calls and 5 telephone calls simultaneously. It is possible to both set up a conference with many participants and also add participants during a conference. Set up a conferen...

  • Page 53

    General use 53.

  • Page 54: 3.5.4 Call

    Tandberg maestro mxp 54 3.5.4 call settings the call settings specifies the quality of the call. Each call will be set up with the default call settings if the settings are not altered. In this case the field is labeled default call settings. If the settings for some reason are altered for the curre...

  • Page 55: 3.5.5

    General use 55 3.5.5 streaming streaming lets you broadcast your meeting to participants on the web. The web participants can listen to the meeting, see snapshots, but not participate themselves. Snapshots of current stream (if multisite), selfview, far end and duovideo streams are accessible via ht...

  • Page 56

    Tandberg maestro mxp 56 streaming source* ƒ auto: enables streaming of both local and far end video. Selection of which site to be streamed is done using voice switching (the site that speaks is streamed). ƒ local: only the local video will be streamed. ƒ remote: only the far end video will be strea...

  • Page 57: 3.6 Answer An Incoming Call

    General use 57 3.6 answer an incoming call how to answer an incoming call: ƒ to accept an incoming call, press the ok button or the green call button on the remote control. How to reject an incoming call: ƒ to reject an incoming call, select the reject icon and press the ok button, or press the end ...

  • Page 58: 3.7  End Call

    Tandberg maestro mxp 58 3.7 end call how to end a call: ƒ press the red end call button on the remote control, or ƒ press the menu button on the remote control to display the menu and select end call. When the end call dialog box is displayed either: ƒ press the red end call button on the remote con...

  • Page 59: 3.8 Standby

    General use 59 3.8 standby the system will automatically go to standby mode when it is not in use. In standby mode, the screen(s) are black. It is however still possible to receive incoming calls. How to enter standby mode manually: ƒ select standby from the menu and select standby now, or ƒ press t...

  • Page 60: 3.8.1

    Tandberg maestro mxp 60 3.8.1 delay standby for 1 hour delay standby for 1 hour postpones the system from entering standby mode for 1 hour. This function is useful when using the monitors for a local presentation to prevent the system from automatically blanking the monitors. It is also possible to ...

  • Page 61: 3.8.2

    General use 61 3.8.2 delay standby for 3 hours delay standby for 3 hours postpones the automatic standby mode for 3 hours. This function is useful when using the monitors for a local presentation to prevent the system from automatically blanking the monitors. It is also possible to postpone the syst...

  • Page 62: 3.8.3

    Tandberg maestro mxp 62 3.8.3 do not disturb to prevent the system from accepting any incoming calls, activete the do not disturb function. The caller will hear a busy tone when calling the system. The monitor will be black when do not disturb is active, see figure below. This is useful when using t...

  • Page 63: 3.9 Phone Book

    General use 63 3.9 phone book the phone book is available via the phone book button on the remote control or from the make a call menu. Using the phone book is time saving and prevents the user from inadvertently calling the wrong number. The contacts are sorted alphabetically. The contact names are...

  • Page 64: 3.9.1 Call

    Tandberg maestro mxp 64 3.9.1 call log the call log lists placed calls, missed calls and received calls. That allows the user to see which calls that are made in the past. The lists contain a maximum of 30 numbers and the numbers are stored in these lists until the system is restarted. If the contac...

  • Page 65: 3.9.2 My

    General use 65 3.9.2 my contacts my contacts are the locally stored contacts on the system. This means that it is possible to add new contacts and edit or delete existing contacts. My contacts can store up to 200 contacts. How to make a call using my contacts: 1. Find the desired contact using the a...

  • Page 66

    Tandberg maestro mxp 66 the following functions are available from my contacts: ƒ call now new contact new multisite contact edit contact delete contact ƒ close.

  • Page 67

    General use 67 3.9.2.1 add new contact the new contact function is available from my contacts . Add a new contact to my contacts by: 1. Select the new contacts button to open the new contacts dialog box. 2. Enter name by using the letter keys on the remote control. Input will automatically be interp...

  • Page 68

    Tandberg maestro mxp 68 3.9.2.2 new multisite contact (optional feature*) the new multisite contact function is available from my contacts . It is possible to pre-define the participants of a conference meeting as a multisite contact. All participants in the multisite contact will then be connected ...

  • Page 69

    General use 69 bandwidth for a multisite contact call when calling a multisite contact, the system will try to call the participants with their specified bandwidths. If the total bandwidth exceeds the system's maximum bandwidth, the system will downspeed and distribute the available bandwidth equall...

  • Page 70

    Tandberg maestro mxp 70 3.9.2.3 edit contact the edit contact function is available from my contacts . How to edit a contact in the local phone book: 1. Select the contact that is to be edited. 2. Press the left arrow on the remote control, followed by the down arrow until the edit contact icon is s...

  • Page 71

    General use 71 3.9.2.4 delete contact the delete contact function is available from my contacts . How to delete a contact: 1. Select the contact that is to be deleted. 2. Press the left arrow on the remote control, followed by the down arrow until the delete contact icon is selected. The delete cont...

  • Page 72: 3.9.3 Global

    Tandberg maestro mxp 72 3.9.3 global contacts when selecting phone book the phone book opens showing the global contacts* or the corporate directory** below the folders placed calls, missed calls, received calls and my contacts. These contacts cannot be changed locally by the system, only from the m...

  • Page 73

    General use 73 3.9.3.1 up one level global contacts can be arranged in a tree structure with several sub folders. Use the up one level button to navigate up in the tree structure. When a search in the global phone book is made, by using the search function, only contacts matching the search text are...

  • Page 74

    Tandberg maestro mxp 74 3.9.3.2 search the phone book can contain an unlimited amount of global contacts. Using search makes it easier to find the wanted contact. How to search in the global phone book: 1. Select the search icon. 2. Enter search text in the dialogue box that appears and press the ok...

  • Page 75

    General use 75 3.9.3.3 copy contact to my contacts the copy contact to my contacts function is available from the placed calls, missed calls, received calls and global contacts folders, see phone book for details. It may be wise to copy contacts that are often used to my contacts. Note that the loca...

  • Page 76: 3.10 Camera Control

    Tandberg maestro mxp 76 3.10 camera control there are several ways to control the camera: ƒ control the camera directly with the arrow keys when the menu is closed or use the move camera function in the menu to control both the near end and far end camera, see move camera and far end control for det...

  • Page 77: 3.10.1

    General use 77 3.10.1 move camera it is possible to move the camera with the remote control or via the menu. Moving the camera directly with the remote control when the menu is hidden, the arrow keys will work on the camera. If the menu is displayed, press the cancel button on the remote control to ...

  • Page 78: 3.10.2

    Tandberg maestro mxp 78 3.10.2 far end control far end control allows you to control your conference partner’s camera. An example of when this feature could be especially helpful is if it is not possible to see what a participant at the far end is writing on their white board. Use far end control to...

  • Page 79: 3.10.3 Camera

    General use 79 3.10.3 camera presets use camera presets to easily vary between predefined near end camera angles. This is useful when pictures from many different camera angles have to be sent to the far end. E.G. In a meeting there is a white board, a pc and a small meeting table. Use camera preset...

  • Page 80: 3.10.4 Tandberg

    Tandberg maestro mxp 80 3.10.4 tandberg tracker how to save presets for the tandberg tracker: 1. Select which camera preset is to be used on the tandberg tracker. 2. Move the camera to the desired position to store on the tracker. 3. Select move camera - save new preset in the menu. 4. All camera pr...

  • Page 81: 3.10.5 Picture

    General use 81 3.10.5 picture control focus, brightness and white balance are set for auto focus, auto brightness and auto white balance by default. If you need to set focus, brightness and white balance manually, go to picture control in the camera control menu. Focus auto auto focus continuously u...

  • Page 82: 3.10.6

    Tandberg maestro mxp 82 3.10.6 camera tracking through camera tracking and the use of two or three microphones, the camera can automatically position itself on the current speaker. Before using camera tracking, the camera positions used must be stored at preset 7 (mic1), preset 8 (mic2) and/or prese...

  • Page 83: 3.11 Presentation

    General use 83 3.11 presentation the presentation functionality in the system enables you to show other available video sources in addition to your main camera. This is perfect for meetings where you would like to show a powerpoint presentation, for example. You can even use arrow keys up and down o...

  • Page 84: 3.11.1

    Tandberg maestro mxp 84 3.11.1 presentation key the quickest way to show a presentation is to use the presentation key on the remote control. The presentation key is used to start and stop a presentation. The presentation key will display pc (default*). When holding the presentation key for 1 second...

  • Page 85: 3.11.2 Presentation

    General use 85 3.11.2 presentation menu the presentation menu offers you all available video sources; main camera, pc, document camera, vcr, aux and vnc. All these sources can be used as main video stream or dual video stream (duo video / h.239). Not all systems has all video sources available, see ...

  • Page 86: 3.11.3

    Tandberg maestro mxp 86 3.11.3 pc presenter (dvi/vga input) (optional feature - not available on all systems) users often have their presentations on a laptop that is brought into the meeting room. Remember to connect your pc to the codec before you press the presentation button. Note that the image...

  • Page 87: 3.11.4

    General use 87 3.11.4 pc soft presenter and vnc (optional feature) pc softpresenter is used to display pc images on your system without using a vga cable (pc presenter). The system and your pc must be connected to the same lan. In addition, vnc (virtual network computing) server software must be ins...

  • Page 88: 3.11.5

    Tandberg maestro mxp 88 3.11.5 dual stream (duovideo tf /h.239) (optional feature - not available on all systems) with dual stream you have the opportunity to show two different live video streams simultaneously, main video and one additional source. This is handy when showing a presentation. You se...

  • Page 89: 3.11.6

    General use 89 3.11.6 take new snapshot the system can take a snapshot of your live video. Snapshot is handy when you are in a call with a system that does not support dual stream. Use snapshot to show a snapshot of your presentation and continue the meeting with main camera. How to use snapshot: yo...

  • Page 90: 3.11.7

    Tandberg maestro mxp 90 3.11.7 display snapshot the system stores the last sent or received snapshot. The snapshot is deleted automatically after the call. How to display snapshots: 1. To view a stored snapshot, first choose the snapshot header. 2. Select display snapshot in the presentation menu. 3...

  • Page 91: 3.12 Conference Services

    General use 91 3.12 conference services a multipoint control unit (mcu) enables several sites to participate in the same conference. During an mcu conference, the status line will provide information about the conference. You can make a multipoint conference in different ways. The conference service...

  • Page 92

    Tandberg maestro mxp 92 example of multisite for mid- to low end systems. Note that the illustrations may differ from the actual product. Using the system’s internal mcu, multisite tf * most tandberg mxp systems have an optional built-in mcu, which is called multisite*. It supports up to 6 video cal...

  • Page 93

    General use 93 using an external mcu with limited chair control support you may have the following services with an external mcu that does not support h.243, you have the following services: ƒ request/release floor ƒ terminal names * the multisite option is not available on the tandberg 550 mxp, tan...

  • Page 94: 3.12.1

    Tandberg maestro mxp 94 3.12.1 request floor and release floor when requesting floor, your video will be broadcasted in full screen to all other participants in the conference. Request floor is useful when you want to speak or display something in front of all participants. Release floor when you ar...

  • Page 95: 3.12.2

    General use 95 3.12.2 conference layout (only supported by tandberg multisite*) with a tandberg multisite you can choose between the layouts: auto split, 4 split, 5+1 split and voice switched view. Auto split displays all participants on the screen simultaneously. 4 split displays the 4 last speakin...

  • Page 96: 3.12.3

    Tandberg maestro mxp 96 3.12.3 terminal names choose terminal names to see a list of the participants of the multisite conference. Press cancel to go back..

  • Page 97: 3.12.4

    General use 97 3.12.4 chair control (not supported by tandberg mcu or multisite) as chairman, you have access to more multisite services. Select chair control to assume the role of chairman of the conference. Select release chair to end the role as chairman. A chair indicator appears when you have c...

  • Page 98: 3.12.5

    Tandberg maestro mxp 98 3.12.5 assign floor and release floor from participant assign floor allows the chairman to select which of the conference participants are to be broadcasted to all other participants..

  • Page 99: 3.12.6

    General use 99 3.12.6 view site and end view (not supported by tandberg mcu or multisite) view site allows you to view any participant in the conference regardless of who has the floor and chair. Choose end view to go back to normal..

  • Page 100: 3.12.7

    Tandberg maestro mxp 100 3.12.7 disconnect participant disconnect participant allows the chairman to disconnect any participant in the conference. In a multipoint call, this is equivalent to disconnecting a participant from the end call menu..

  • Page 101: 3.12.8

    General use 101 3.12.8 terminate meeting terminate meeting allows the chairman to terminate the conference altogether. In a multisite call, this is equivalent to pressing end all calls from the end call menu..

  • Page 102: 3.12.9

    Tandberg maestro mxp 102 3.12.9 more about multisite (embedded mcu) (optional feature*) calling in to a multisite any system can be part of a multisite conference by calling in to a multisite. The dial-in numbers to the multisite depends of the network that is used. To dial in to the multisite on ip...

  • Page 103

    General use 103 by connecting multisite systems together, it is possible to connect even more sites in a cascaded multisite (see example below). All connections can use any combination of isdn/ip. The host can connect up to 5 other video systems with multisite functionality. The cascaded systems can...

  • Page 104: 3.13 Control Panel

    Tandberg maestro mxp 104 3.13 control panel the control panel contains the features: diagnostics text chat audio demonstration administrator settings restart user guide.

  • Page 105: 3.13.1 Diagnostics

    General use 105 3.13.1 diagnostics diagnostics allows testing of individual system components and displays the current system settings. Diagnostics contain: system information channel status call status system selftest view administrator settings ip address conflict check warnings.

  • Page 106: 3.13.2 System

    Tandberg maestro mxp 106 3.13.2 system information select system information to view system numbers, line status, software version, hardware serial number and other useful information. Press arrow key up and down to scroll in the system information list. System information contains: system name my i...

  • Page 107: 3.13.3 Channel

    General use 107 3.13.3 channel status comprehensive information about the call progress is available through the channel status window. This window indicates the various stages each b-channel goes through whilst establishing a connection. Status - bri comments idle calling connected sync active rele...

  • Page 108

    Tandberg maestro mxp 108 pri yellow alarm yellow alarm or remote alarm indicator (rai) means that the system is receiving framing info, but in this framing info the other side tells the system that it is not reading the system’s transmitted framing info. Typically, this may be a broken connector in ...

  • Page 109: 3.13.4 Call

    General use 109 3.13.4 call status comprehensive information about the call is available through the call status window. The menu has two columns, one for transmitted and one for received audio/video/data information. If dual stream or multisite is available on your system and in use, pressing the u...

  • Page 110: 3.13.5 System

    Tandberg maestro mxp 110 3.13.5 system selftest the system performs a check to determine internal hardware integrity. System selftest is useful when you want to check if your network connection is active..

  • Page 111: 3.13.6

    General use 111 3.13.6 view administrator settings this window displays all the system settings. Use the arrow key on the remote control to scroll through the list. View administrator settings may contain*: general settings system name language dual monitor auto answer max call length access code in...

  • Page 112

    Tandberg maestro mxp 112 pc document camera vcr aux vnc split screen default call settings call type network bandwidth restrict (56k) auto h320 bandwidth auto h323 bandwidth sip audio settings inputs mic1 mic2 mic3 audio4 audio5 audio6 mix mode vcr ducking level settings mic1 mic2 mic3 audio4 audio5...

  • Page 113

    General use 113 white balance brightness video name main cam aux doc cam vcr pc vga vnc network type isdn-bri\pri\leased e1\t1\enternal h331 isdn switch type etsi (euro isdn),… line1 setup on number1 number2 spid1 spid2 line2 setup on number1 number2 spid1 spid2 line3 setup on number1 number2 spid1 ...

  • Page 114

    Tandberg maestro mxp 114 ip address ip subnet mask gateway ethernet speed h.323 settings e.164 alias use gatekeeper gatekeeper ip h.323 prefix advanced h.323 settings rsvp nat nat address qos ip precedence audio video data signaling ip type of service (tos) diffserv audio video data signaling snmp s...

  • Page 115: 3.13.7

    General use 115 3.13.7 ip address conflict check the system will give a warning if there is an ip conflict. The user may initiate this check by selecting ip address conflict check..

  • Page 116: 3.13.8 Warnings

    Tandberg maestro mxp 116 3.13.8 warnings any warnings registered by the system will be displayed in the warnings menu. Open a warning in the list to get more information about the warning. The following warnings may be displayed if detected by the system, depending on system type and configuration: ...

  • Page 117

    General use 117 ƒ there is something wrong with the leased e1/t1 line (yellow alarm). Please check your network connection. (193) h323 gatekeeper warnings ƒ could not register to the gatekeeper. ƒ the gatekeeper rejected to register the system. Another system is already registered with the same alia...

  • Page 118: 3.13.9

    Tandberg maestro mxp 118 3.13.9 text chat while in an isdn or ip call to another system supporting text chat (t.140), select text chat from the control panel. Enter text in the displayed window. How to use text chat: 1. Choose text chat from the control panel to open the text chat window. 2. Enter t...

  • Page 119: 3.13.10 Audio Demo

    General use 119 3.13.10 audio demo note that the audio demo will only appear in the user guide if a digital natural audio module is connected to the codec..

  • Page 120

    Tandberg maestro mxp 120 3.13.11 administrator settings administrator settings contains the configuration of the whole system. It is recommended to password protect administrator settings to prevent occasional users from making changes to the system. See administrator settings for further details..

  • Page 121: 3.13.12  Restart

    General use 121 3.13.12 restart restart the system by pressing the restart button. You are prompted with a dialog box saying: do you want to restart the system? Press ok to restart, press cancel (x) to abort..

  • Page 122: 3.13.13   User Guide

    Tandberg maestro mxp 122 3.13.13 user guide the on screen user guide takes you through a quick step-by-step introduction to videoconferencing. It gives the user basic skills in how to use the system..

  • Page 123: 4 Administrator Settings

    4 administrator settings administrator settings contain all the settings of the system. Making changes to administrator settings will change the behavior of the system. It is recommended to password protect the access to administrator settings to prevent occasional users from making crucial changes ...

  • Page 124: 4.1 General Settings

    Tandberg maestro mxp 124 4.1 general settings when installing the system, go through the general settings menu to ensure that you have the right settings for your system, see system configuration. General settings contain: language system name / international name * auto answer phone book settings e...

  • Page 125: 4.1.1 Language

    Administrator settings 125 4.1.1 language the system supports 16 different languages for its on-screen menus; english, german, french, norwegian, swedish, italian, spanish, portuguese, russian, finnish, chinese simplified, chinese traditional, japanese, korean, thai and arabic. Select the preferred ...

  • Page 126: 4.1.2 System

    Tandberg maestro mxp 126 4.1.2 system name system name identifies the system: ƒ on the welcome page. ƒ during an mcu conference call. ƒ when using the web-interface. ƒ when the codec is acting as an snmp agent. ƒ towards a dhcp server. ƒ h323 id. Other systems can call in using this name instead of ...

  • Page 127: 4.1.3 International

    Administrator settings 127 4.1.3 international name if the system name contains asian and non-latin character text input, the international name using latin characters only, must be specified as well. This is in order to make other systems understand the system name..

  • Page 128: 4.1.4 Auto

    Tandberg maestro mxp 128 4.1.4 auto answer the auto answer setting decides whether an incoming call is put through automatically or manually. On the system will automatically answer all incoming calls. On+mic off the system will automatically answer all incoming calls and switch the microphone off w...

  • Page 129: 4.1.5 Phone

    Administrator settings 129 4.1.5 phone book settings corporate directory on the corporate directory is available in the menu. Off the corporate directory is hidden from the menu and is unavailable for users. Ip address enter the ip address of the management system that provides the phone book. Path ...

  • Page 130: 4.1.6

    Tandberg maestro mxp 130 4.1.6 external services settings external services on when set to on external services are available. Off when set to off external services are unavailable. Ip address enter the ip address of the service provider for external services. Path enter the path to the external ser...

  • Page 131: 4.1.7 Permissions

    Administrator settings 131 4.1.7 permissions permissions contains settings for incoming mcu calls, incoming telephone calls, far end control, remote software upgrade and fallback to telephony. Access code an access code will help you control the use of the system. All users must enter a code to iden...

  • Page 132

    Tandberg maestro mxp 132 far end camera control on the far end will be able to: • control your camera • select your video sources • activate your camera presets • request snapshots off the far end can access none of the four features above on the local system. You will however still be able to contr...

  • Page 133: 4.1.8 Screen

    Administrator settings 133 4.1.8 screen settings auto layout on if auto layout is on the system will change layouts automatically depending on the number of participants in a call and if you have a dual video stream or not. Please refer to layout for more information. Off if auto layout is off there...

  • Page 134

    Tandberg maestro mxp 134 picture layout the advanced picture layout is related to the layout button on the remote control and it can be used at any time to change the screen layout. For wide screen systems pop mode is recommended. You will get optimized picture layouts for wide screen by pressing th...

  • Page 135

    Administrator settings 135 example of 1+2 picture outside picture (wide screen). Example of 1+3 picture outside picture (wide screen). Note that if both tv monitor format and vga format is set to normal, the system will skip the 1+3 layout, which is not beneficial for 4:3 monitors. Note that the fol...

  • Page 136

    Tandberg maestro mxp 136 vga monitor format to fully leverage your wide screen display, activate the native 16:9 format by setting the vga monitor format to wide. Note that you should only change this setting if your vga monitor is a wide screen (16:9) monitor or projector. The vga and dvi output wi...

  • Page 137

    Administrator settings 137 auto vga output format will be optimized dependant of the video source format, refresh and of the edid information available. Supported formats are: svga (800x600) 75hz xga (1024x768) 60hz / 75hz wxga (1280x768) 60hz svga 800x600 75hz vga output format is forced to svga fo...

  • Page 138

    Tandberg maestro mxp 138 pc presentation shown in wide (stretched) mode..

  • Page 139: 4.1.9 Software

    Administrator settings 139 4.1.9 software options the system requires a valid option key to activate multisite and/or presenter functionality. In order to activate additional bandwidth, you need to enter a bandwidth key. A restart of the system is required after entering a new option and/or bandwidt...

  • Page 140: 4.1.10

    Tandberg maestro mxp 140 4.1.10 date and time settings ntp ip this is the ntp time server address from which the system can get updated time information. See ip services for more details. Auto the ntp ip address is set automatically. Manual the ntp ip address is set manually. Ip address the ip addre...

  • Page 141: 4.2 Menu Settings

    Administrator settings 141 4.2 menu settings menu settings contain the settings: input editor language menu timeout in call menu on tv menu on pc balloon help administrator password kiosk mode settings startup icons.

  • Page 142: 4.2.1

    Tandberg maestro mxp 142 4.2.1 input editor language when the input editor language is set to chinese, korean or japanese the user will be able to enter chinese / korean / japanese characters into an input field like the system name or phone book, using the remote control..

  • Page 143: 4.2.2

    Administrator settings 143 4.2.2 menu timeout in call the main menu appears on the bottom line of the screen. Set menu timeout in call to on if you want the menu to time out automatically when you are in a call. On the menus will time out automatically after 15 seconds if there is no activity on the...

  • Page 144: 4.2.3 Menu

    Tandberg maestro mxp 144 4.2.3 menu on tv the menu on tv setting decides if the menu shall be displayed on the tv screen or not. For optimal layout of the menu, menu on tv should be off if menu on pc is on and vice versa. On the menu is available on the tv screen. Off the menu is not available on th...

  • Page 145: 4.2.4 Menu

    Administrator settings 145 4.2.4 menu on pc the menu on pc setting decides if the menu shall be displayed on the pc (vga screen) screen or not. For optimal layout of the menu, menu on tv should be off if menu on pc is on and vice versa. On the menu is available on the pc screen. Off the menu is not ...

  • Page 146: 4.2.5 Balloon

    Tandberg maestro mxp 146 4.2.5 balloon help it is possible to enable / disable the balloon help window. On choose on if you want help text windows to appear. Off there will be no help text window..

  • Page 147: 4.2.6

    Administrator settings 147 4.2.6 administrator password it is recommended to put an administrator password on the system. The administrator password can be maximum 5 digits long. The administrator password dialog box will pop up when you choose administrator settings from the control panel. This wil...

  • Page 148: 4.2.7

    Tandberg maestro mxp 148 4.2.7 kiosk mode settings kiosk mode in kiosk mode the system is set to a simplified state where it can be controlled with just the four arrow keys and ok. You will get a simplified on-screen menu with only basic functionality available: ƒ make calls (using predefined contac...

  • Page 149

    Administrator settings 149 if language menu is enabled you will first see the language selection menu. Select language and the welcome menu will be displayed with your desired language. In a call, the system will display far end video in full screen. If max call length is set to a value and the syst...

  • Page 150

    Tandberg maestro mxp 150 kiosk mode - auto dial* on the system will automatically dial to the first contact in the phone book when he handset is lifted. If this contact is busy, the system will call the second number in the phone book and so on. If the user places the handset in the cradle, the syst...

  • Page 151: 4.2.8 Startup

    Administrator settings 151 4.2.8 startup welcome menu the welcome menu contains the main menu, system status, your system name and dial in numbers. On the welcome menu is shown when the system wakes up from standby mode. Off the welcome menu is not shown when the system wakes up from standby mode. P...

  • Page 152

    Tandberg maestro mxp 152 on welcome text is displayed on the welcome menu. Off welcome text is not displayed on the welcome menu. Welcome text you can change the welcome text to any text you like, instead of the default text. Remember that display welcome text must be on to be able to edit the welco...

  • Page 153: 4.2.9 Icons

    Administrator settings 153 4.2.9 icons the following indicator icons may be set to on or off: ƒ mic off ƒ volume off ƒ on air ƒ encryption ƒ bad network ƒ telephone see on-screen indicators for details..

  • Page 154: 4.3 Presentation Settings

    Tandberg maestro mxp 154 4.3 presentation settings presentation settings contain: presentation start h.239 startup video source presentation source snapshot source auto-display snapshot pip appearance pip placing vnc settings.

  • Page 155: 4.3.1 Presentation

    Administrator settings 155 4.3.1 presentation start if your system has dual stream capabilities, you can show two video streams at the same time (see also dual stream ). Presentation start is auto by default. This means that you will start dual stream (a second video stream) automatically when start...

  • Page 156: 4.3.2 H.239

    Tandberg maestro mxp 156 4.3.2 h.239 h.239 supports transmission of two video streams. It combines elements of duo video and people+content. If h.239 is disabled you will still be able to start tandberg dual video stream* enabled enables h.239 disabled disables h.239 * the tandberg 550 mxp can only ...

  • Page 157: 4.3.3

    Administrator settings 157 4.3.3 startup video source the startup video source is the video source on display when the system wakes up from standby mode. If you use main camera as start up source, the system will start with main camera every time the system wakes up from standby, regardless of what ...

  • Page 158: 4.3.4 Presentation

    Tandberg maestro mxp 158 4.3.4 presentation source the presentation source is connected to the presentation button on the remote. Pressing the presentation button will put the presentation source on display. Presentation source is pc by default*. You can change the presentation source to any video s...

  • Page 159: 4.3.5 Snapshot

    Administrator settings 159 4.3.5 snapshot source when you take a snapshot, you get a snapshot of the snapshot source. Current is the default snapshot source. This means that you take a snapshot of the video source that is currently active. You can change the snapshot source to any video source. In t...

  • Page 160: 4.3.6 Auto-Display

    Tandberg maestro mxp 160 4.3.6 auto-display snapshot select auto to automatically display a received snapshot. Turn auto-display snapshot manual if you wish not to have them displayed on the screen when they are sent or received. The snapshots will be sent and received, but not displayed. With auto-...

  • Page 161: 4.3.7 Pip

    Administrator settings 161 4.3.7 pip appearance a picture in picture (pip) is a smaller picture placed in one of the corners of the screen. The pip enables you to see an extra picture in your video conference. Auto pip auto means that picture in picture will appear automatically when it is suitable....

  • Page 162: 4.3.8 Pip

    Tandberg maestro mxp 162 4.3.8 pip placing pip placing lets you decide where the pip shall appear. You can of course move the pip with the layout button on the remote anytime. Top right pip is placed in the top right corner. Bottom right pip is placed in the bottom right corner. Bottom left pip is p...

  • Page 163: 4.3.9 Vnc

    Administrator settings 163 4.3.9 vnc settings vnc settings is necessary when using a vnc presentation. See chapter pc soft presenter and vnc for more information on how to use vnc. Address the ip-address of the pc with the vnc software installed. To find the ip- address of the pc, place the mouse po...

  • Page 164: 4.4 Call Quality

    Tandberg maestro mxp 164 4.4 call quality call quality contains the settings: video algorithm audio algorithm aac-ld 128kbps natural video max upstream rate video quality default call settings.

  • Page 165: 4.4.1 Video

    Administrator settings 165 4.4.1 video algorithm the system will automatically select the best video algorithm based on the video source and the capabilities of the remote system. Use this menu to disable video algorithms in case you have interoperability issues calling other systems. H.264 bandwidt...

  • Page 166: 4.4.2 Audio

    Tandberg maestro mxp 166 4.4.2 audio algorithm the system will automatically select the best audio algorithm based on the call rate and the capabilities of the remote system. Use this menu to disable audio algorithms in case you want to remove “low quality” audio, or if you have interoperability iss...

  • Page 167: 4.4.3

    Administrator settings 167 4.4.3 aac-ld 128kbps (stereo audio) specify a call rate for 128kbps aac-ld. From this call rate and above, "128kbps aac-ld" is available. On lower call rates "64kbps aac-ld" is available. Stereo audio requires twice the bandwidth as mono cd-quality audio. Therefore we reco...

  • Page 168: 4.4.4 Natural

    Tandberg maestro mxp 168 4.4.4 natural video choosing natural video will enable 60 fields* per second true interlaced picture for high motion video. The use of natural video requires the h.263+ and h.263++ video protocols. Natural video will be disabled in h.323 multisite calls and in h.320 continuo...

  • Page 169: 4.4.5

    Administrator settings 169 4.4.5 max upstream rate (kbps) the max upstream rate (kbps) defines the desired maximum transmitted call rate. This is to be able to limit the outgoing bandwidth whilst keeping the maximum incoming bandwidth, especially useful for home offices with different upstream and d...

  • Page 170: 4.4.6 Video

    Tandberg maestro mxp 170 4.4.6 video quality the different video sources need different video quality settings. Main camera, vcr, aux and split screen have motion as default. Pc, document camera and vnc have sharpness as default. Motion* optimized for smooth motion video (cif/sif or w288p for low ba...

  • Page 171

    Administrator settings 171 sharpness*: improved quality of detailed images and graphics, lower frame rate, ideal for enhancing quality at lower bandwidths. ƒ 4cif will be used from a pal video input, digital clarity ƒ 4sif from ntsc, digital clarity ƒ w720p will be used from a wide format (hd720p) i...

  • Page 172

    Tandberg maestro mxp 172 native pal: ƒ 4cif (704 x 576 pixels), digital clarity ƒ 448p (576 x 448) ƒ icif (352 x 576 pixels), natural video ƒ cif (352 x 288 pixels) ƒ qcif (176 x 144 pixels) ƒ sqcif (128 x 96 pixels) native pc resolutions: ƒ xga (1024 x 768 pixels), digital clarity ƒ svga (800 x 600...

  • Page 173: 4.4.7

    Administrator settings 173 4.4.7 default call settings default call settings are connected with call settings in the call menu. If you leave call settings unchanged when making a call, the system will use the default call settings in the call. In addition to the call settings call type, net, bandwid...

  • Page 174

    Tandberg maestro mxp 174 select isdn to ensure that the call is set up as an isdn call. Select h.323 to ensure that the call is set up as an h.323 call. Select sip to ensure that the call is set up as an sip call. Bandwidth bandwidth decides the quality of the video picture. When set to auto the sys...

  • Page 175

    Administrator settings 175 these types of calls are often referred to as ƒ h.221 calls ƒ 2x64 calls ƒ 2x56 calls - as making 2 x 64 kbps or 2 x 56 kbps calls to the same system. Place this type of call by: ƒ set network to isdn ƒ set bandwidth to 128 kbps ƒ a field for the 2nd number pops up in call...

  • Page 176: 4.5 Audio

    Tandberg maestro mxp 176 4.5 audio audio contains the settings: inputs outputs echo control stereo settings audio leveling (agc) alert tones and volume.

  • Page 177: 4.5.1 Inputs

    Administrator settings 177 4.5.1 inputs mic 1- 3 and audio input 4-6 by default, all inputs are enabled. Just plug in an audio source and it is active. Audio inputs that are on will automatically be mixed. Unconnected inputs will automatically be muted. Select off to prevent audio/noise from connect...

  • Page 178

    Tandberg maestro mxp 178 it is possible to adjust the audio input levels according to which external audio equipment is connected. The on-screen audio level indicator will make it easier to set the correct input level settings. The input level should be adjusted so that the average level reaches the...

  • Page 179

    Administrator settings 179 tandberg audio science microphone elements: audio technica at-861pz and crown pzm- 6d signal levels - microphone inputs clipping level nominal level input menu level settings vpp dbu dbu 0.0 db 83.0 mvpp -28.4 dbu -46.4 dbu 1.5 db 69.8 mvpp -29.9 dbu -47.9 dbu 3.0 db 58.8 ...

  • Page 180

    Tandberg maestro mxp 180 signal levels - line level inputs clipping level nominal level input menu level settings vpp dbu dbu 0.0 db 15.5 vpp 17.0 dbu -1.0 dbu 1.5 db 13.0 vpp 15.5 dbu -2.5 dbu 3.0 db 11.0 vpp 14.0 dbu -4.0 dbu 4.5 db 9.2 vpp 12.5 dbu -5.5 dbu 6.0 db 7.8 vpp 11.0 dbu -7.0 dbu 7.5 db...

  • Page 181: 4.5.2 Outputs

    Administrator settings 181 4.5.2 outputs audio out 1 - 3 audio out 1 is intended for connection to tandberg digital natural audio module, televisions or audio amplifiers. Audio out 2 is intended for connection to audio recording equipment or to a telephone add-on hybrid. The signal is a mix of audio...

  • Page 182

    Tandberg maestro mxp 182 signal levels - line level outputs* absolute max. Output level nominal level output menu level settings vpp dbu dbu 0.0 db 1.2 vpp -5.5 dbu -23.5 dbu 1.5 db 1.4 vpp -4.0 dbu -22.0 dbu 3.0 db 1.6 vpp -2.5 dbu -20.5 dbu 4.5 db 1.9 vpp -1.0 dbu -19.0 dbu 6.0 db 2.3 vpp 0.5 dbu ...

  • Page 183: 4.5.3 Echo

    Administrator settings 183 4.5.3 echo control mic 1-3 and audio 4 each of the 3 microphone inputs and audio input 4 has a separate acoustic echo canceller. One echo canceller per input provides more sophisticated control than having one common canceller for all microphones. In addition to echo cance...

  • Page 184: 4.5.4 Stereo

    Tandberg maestro mxp 184 4.5.4 stereo settings settings output response out 1 mode* stereo i/o mode stereo speakers audio out 1 audio out 2 audio out 3 analog off off loudspeaker mono aux vcr analog off on loudspeaker left loudspeaker right vcr analog on off loudspeaker mono vcr-left vcr-right analo...

  • Page 185

    Administrator settings 185 note that if stereo speakers are enabled in the menu without having any stereo speakers connected to the digital nam, it may cause the acoustic echo-canceller to malfunction. If the system is connected to a digital nam, stereo sound on the loudspeakers shall be present if ...

  • Page 186: 4.5.5

    Tandberg maestro mxp 186 4.5.5 audio leveling (agc) on select on to allow automatic adjustments (automatic gain control) of audio levels. When on, the agc maintains the audio signal level at a fixed value by attenuating strong signals and amplifying weak signals. Very weak signals, i.E. Noise alone,...

  • Page 187: 4.5.6

    Administrator settings 187 4.5.6 alert tones and volume video call alert tone and telephone alert tone to help distinguish between incoming video calls and ordinary telephone calls, it is recommended to use different ringing tones for video calls and telephone calls. Alert volume you may change the ...

  • Page 188: 4.6 Video

    Tandberg maestro mxp 188 4.6 video video contains the settings: camera tracking mode mcu status line floor to full screen web snapshots multisite picture mode video name.

  • Page 189: 4.6.1

    Administrator settings 189 4.6.1 camera tracking mode slow the system waits a while before zooming in on a single person speaking. Suitable when wide-angle images are preferred over close-up images. Normal should be used in regular meetings. Fast the system quickly zooms in on a single person speaki...

  • Page 190: 4.6.2

    Tandberg maestro mxp 190 4.6.2 mcu status line on the multisite / mcu / duovideo indicators will be displayed and provide information about the conference. Off the multisite / mcu / duovideo indicators will not be displayed. Auto the multisite / mcu / duovideo indicators will be displayed for a few ...

  • Page 191: 4.6.3

    Administrator settings 191 4.6.3 floor to full screen when "floor to full screen" is enabled, someone who requests floor will be seen by all participants as full screen. When "floor to full screen" is "off", someone who request floor in a multisite conference using the 5+1 layout will be seen in the...

  • Page 192: 4.6.4 Web

    Tandberg maestro mxp 192 4.6.4 web snapshots the system is able to generate jpeg snapshots and provide them when requested (as ‘http get’ or via ftp). See appendix 6 for descriptions of the possible snapshot files. On snapshots generation is enabled. Off snapshots generation is disabled. Note that w...

  • Page 193: 4.6.5

    Administrator settings 193 4.6.5 multisite picture mode multisite* picture mode determines the default layout of a multisite call. Available layouts are: auto split, 4 split, 5+1 split, and voice switched. You can change the layout during a call using the layout option in multisite services. Auto sp...

  • Page 194

    Tandberg maestro mxp 194 voice switched mode.

  • Page 195: 4.6.6 Video

    Administrator settings 195 4.6.6 video name as a default, the video inputs are given the names main cam, pc, doc cam, vcr, aux or vnc, dependent on what video sources are available on your system. The video names cannot exceed eight characters. The names correspond to the video names in the presenta...

  • Page 196: 4.7 Security

    Tandberg maestro mxp 196 4.7 security security contains the settings: encryption encryption mode passwords.

  • Page 197: 4.7.1 Encryption

    Administrator settings 197 4.7.1 encryption (country specific) auto the system will try to set up calls using encryption. Point to point calls: if the far end system supports encryption (aes or des), the call will be encrypted. If not, the call will proceed without encryption. Multisite calls*: in o...

  • Page 198: 4.7.2 Encryption

    Tandberg maestro mxp 198 4.7.2 encryption mode auto the system will try to use the most secure encryption - aes, dependent on the capabilities of the other sites. For sites that do not support aes encryption, des encryption will be tried. Aes the system will try to use aes with 128 bits encryption w...

  • Page 199: 4.7.3 Passwords

    Administrator settings 199 4.7.3 passwords administrator password, ip access password, streaming password, vnc password, access code and remote software upgrade password are duplicated from their respective menus. Using the security menu gives you a quick way to change all passwords of the system..

  • Page 200: 4.8 Network

    Tandberg maestro mxp 200 4.8 network the network menu contain: isdn/external/leased e1/t1 lan settings network profiles data port.

  • Page 201: 4.8.1

    Administrator settings 201 4.8.1 isdn/external/leased e1/t1 network type before using the system it is necessary to specify which network to use and define its settings. Isdn- bri if you want to use your system via isdn-bri, you should select network type: isdn-bri and enter the isdn bri settings me...

  • Page 202

    Tandberg maestro mxp 202 4.8.1.1 isdn-bri settings to make sure your system will work properly using isdn-bri, make the following settings: 1. Set isdn switch type 2. Enter isdn line numbers (+ spids if required) 3. Disable unused lines some software versions do not support 6 isdn lines, therefore s...

  • Page 203

    Administrator settings 203 advanced isdn settings sub address using a sub address enables you to connect up to eight isdn terminals to the same isdn telephone number and line. The terminals are addressed by using different sub addresses. To call a terminal with a sub address, separate the isdn telep...

  • Page 204

    Tandberg maestro mxp 204 4.8.1.2 isdn-pri settings to make sure your system will work properly using isdn-pri, configure the following settings: 1. Set pri switch type 2. Enter pri line number note that the t1 format is predefined to esf and the line code is b8zs. This is not configurable. Number ra...

  • Page 205

    Administrator settings 205 example: max channels may be used for pris that are provisioned for a lower number of channels. High channel, low channel and search may be used for pris provisioned with specific requirements for b-channel usage. In the example above, the system will start searching for a...

  • Page 206

    Tandberg maestro mxp 206 example: at&t offers several digital switched services. These include sdn with service code 1 and accunet with service code 6. Below is a list of common service profiles. As these profiles may change, contact your service provider to get the correct profile. Service profiles...

  • Page 207

    Administrator settings 207 4.8.1.3 leased e1/t1 settings call control auto when auto is selected, the system will automatically initiate a connection as soon as it detects that the far end tries to make a call. This mode is also commonly known as "data triggered" mode, because the existence of certa...

  • Page 208

    Tandberg maestro mxp 208 4.8.1.4 external network settings before using the system together with external network equipment, you must specify the network parameters on this page. The system has support for up to 2 mbps (depending on the bandwidth key loaded) using the external network (rs449/v.35/x....

  • Page 209

    Administrator settings 209 network clocking the network clock setting specifies the number of physical external clock signals. Rs449/v35 compatible use rs449/v35 compatible when the external equipment provides two clock signals, one for transmit and one for receive. The difference between rs449 and ...

  • Page 210

    Tandberg maestro mxp 210 4.8.1.5 h.331 settings on used when broadcasting a videoconference from one site to many others, e.G. Via satellite, where there is no possibility to negotiate quality between the receivers and the originator due to one-way communication. Off standard two-way communication w...

  • Page 211: 4.8.2 Lan

    Administrator settings 211 4.8.2 lan settings lan settings contain: ip settings h.323 settings sip settings snmp settings ip services quality of service 802.1x settings.

  • Page 212

    Tandberg maestro mxp 212 4.8.2.1 ip settings remember to restart the system after making changes to ip settings. This can be done by selecting the “save and restart” at the bottom of the ip setting menu. Changes in ip settings menu will not have any effect until the system is restarted. Ip protocol ...

  • Page 213

    Administrator settings 213 ethernet speed auto the codec will auto-detect the speed/duplex on the lan. 10/half the codec will connect to the lan using 10mbps speed/half duplex. 10/full 10 mbps speed/full duplex. 100/half 100 mbps speed/half duplex. 100/full 100 mbps speed/full duplex. Ip access pass...

  • Page 214

    Tandberg maestro mxp 214 dns settings dns server 1-5 dns server defines the network addresses for dns servers. Up to 5 addresses may be specified. If the network addresses are unknown, please contact your administrator or internet service provider. Dns domain name dns domain name is the default doma...

  • Page 215

    Administrator settings 215 4.8.2.2 h.323 settings e.164 alias this is the e.164 address of the system. The e.164 address is equivalent to a telephone number, sometimes combined with access codes. Valid characters are 0-9,* and #. When using a gatekeeper, the system will send a message to the gatekee...

  • Page 216

    Tandberg maestro mxp 216 gatekeeper settings gatekeeper discovery auto the system will automatically try to register to any available gatekeeper. If a gatekeeper responds to the request sent from the codec within 30 seconds this specific gatekeeper will be used. This requires auto discovery on the g...

  • Page 217

    Administrator settings 217 callmanager settings callmanager ip this is the callmanager ip-address that is used if you specify h.323 call setup: callmanager..

  • Page 218

    Tandberg maestro mxp 218 advanced h.323 settings the advanced h.323 settings only have an effect if they are supported by your ip infrastructure. Nat nat, network address translation, is used when a pc and a videoconferencing system are connected to a router with nat support. Nat support in the vide...

  • Page 219

    Administrator settings 219 4.8.2.3 sip settings mode on setting the sip mode to on will enable the system for incoming and outgoing sip calls. Off setting the sip mode to off will disable incoming and outgoing sip calls from the system. Display name the display name part of the sip address (uri) is ...

  • Page 220

    Tandberg maestro mxp 220 the server address is the manually configured address for the outbound proxy and registrar. It is possible to use a fully qualified domain name, or an ip address. The default port is 5060 for tcp and udp, but another one can be provided. Server address: examples: “sipserver....

  • Page 221

    Administrator settings 221 ƒ rfc 2429 rtp payload format for the 1998 version of itu-t rec. H.263 video (h.263+) ƒ draft-ietf-avt-rfc2429-bis-05.Txt - draft for advanced video signaling including resolution, mpi, annexes and custom formats. ƒ rfc 3047 rtp payload format for itu-t recommendation g.72...

  • Page 222

    Tandberg maestro mxp 222 4.8.2.4 snmp settings snmp settings snmp trap host identifies the ip-address of the snmp manager. Snmp (simple network management protocol, snmp ver 1) is used for monitoring and configuring of different entities in a network. The system's snmp agentresponds to requests from...

  • Page 223

    Administrator settings 223 4.8.2.5 ip services ntp ip this is the ntp time server address from which the system can get updated time information. This is a requirement for proper operation if h.235 authentication is implemented. The network time protocol (ntp) is used to synchronize the time of the ...

  • Page 224

    Tandberg maestro mxp 224 4.8.2.6 quality of service qos type off no qos is used. Diffserv diffserv qos method is used. Please see below for details. Ip precedence ip precedence qos method is used. Please see below for details. Ip precedence video used to define which priority audio, video, data and ...

  • Page 225

    Administrator settings 225 auto will provide the following priority: audio 4 diffserv video used to define which priority audio, video, data and signaling packets should have in an ip network. The priority ranges from 0 to 63 for each type of packets. Diffserv telephony used to define which priority...

  • Page 226

    Tandberg maestro mxp 226 4.8.2.7 ieee 802.1x 802.1x the system may be connected to an ieee 802.1x lan network. Supported 802.1x protocols are eap-md5, eap-peap and eap-ttls. The 802.1x authentication are enabled by setting 802.1x mode to on. On 802.1x authentication enabled off 802.1x authentication...

  • Page 227: 4.8.3 Network

    Administrator settings 227 4.8.3 network profiles this menu consists of 7 network profiles; a prefix can be added for each profile. If you add a prefix to a profile, this prefix will automatically be added in front of the number being dialed. Example: 0 is added as a call prefix to the 2nd profile, ...

  • Page 228: 4.8.4 Data

    Tandberg maestro mxp 228 4.8.4 data port the system provides up to two standard rs232 serial ports to allow a computer to be connected for data transfer and control purposes. Note that when connecting to a pc the connecting cable must be a straight through rs232 cable. Baud rate, parity, databits an...

  • Page 229: 4.8.5

    Administrator settings 229 4.8.5 restore default settings restore default settings will restore all administrator settings. Note that this will not affect your call directory information, network type, line setup numbers or your spid numbers..

  • Page 230: 5 Peripheral Equipment

    5 peripheral equipment using the optional peripheral devices outlined in this chapter and the many others available, you will be able to build your own applications for use with the system, thereby better integrating the system into your business environment. This chapter will explain how to connect...

  • Page 231: 5.1 Interfaces

    Peripheral equipment 231 5.1 interfaces 5.1.1 video 5 video inputs: ƒ 2 video inputs supporting s-video through mini-din connectors. ƒ 2 video inputs supporting composite signals through rca connectors. ƒ 1 vga/dvi-i (dvi = digital video interface, i = integrated digital & analog) input, analog or d...

  • Page 232

    Tandberg maestro mxp 232 levels: ƒ composite: 1 vpp, 75 ohm ƒ s-video (y/c): ƒ y: 1 vpp, 75 ohm ƒ c (pal): 0.3 vpp, 75 ohm ƒ c (ntsc): 0.28 vpp, 75 ohm vga formats supported on 'dvi-i out': svga (800x600) 75hz xga (1024x768) 60hz wxga (1280x768) 60hz hd720p (1280x720) 50,60 hz dvi and specifications...

  • Page 233

    Peripheral equipment 233 supported dvi cables: tandberg supports dvi-d single-link, dvi-a and dvi-i single-link format cables. Dvi-d cables transmit digital t.M.D.S. Signals, dvi-a cables transmit analog vga signals and dvi-i cables can transmit either digital or analog signals. It is possible to ex...

  • Page 234

    Tandberg maestro mxp 234 pc cable, vga - dvi with integrated audio signal name conn. 1 conn. 2 conn. 3 conn. 4 conn. 5 cable color ddc clock 6 15 orange ddc data 7 12 white vertical sync 8 14 yellow ddc power (+5v) 14, 16 9 red digital return 15 5, 10 black rgb red c1 1 red coax rgb green c2 2 green...

  • Page 235: 5.1.2 Audio

    Peripheral equipment 235 5.1.2 audio 6 audio inputs: ƒ 3 microphone inputs (balanced, 24v phantom powered) via xlr connectors. ƒ 3 audio inputs (line level) via rca connectors. All audio inputs are active by default. For further information, refer to chapter audio . Audio input connector specificati...

  • Page 236: 5.1.3 Network

    Tandberg maestro mxp 236 audio output connector specification: connector label audio outputs signal type unbalanced connector (codec) female rca/phono, sleeve-ground, centre-signal output impedance 680 ohms max output level when set to maximum output level and volume control set to max. Max output l...

  • Page 237

    Peripheral equipment 237 isdn bri interface: isdn i.420 (rj-45 jack) basic rate interface s/t (2b+d), 128 kbps per isdn i/f to connect the system to bri, use the isdn cable provided by tandberg (or a standard bri cable). The pinout of the s/t interface is: bri pinout pin-3 tx+ pin-4 rx+ pin-5 rx- pi...

  • Page 238

    Tandberg maestro mxp 238 v35: v.10 (rs423). For balanced signals a "0"=low voltage is defined as terminal a positive with respect to terminal b. For unbalanced signals a "0"= low voltage is defined as terminal positive with respect to gnd. Cable length max: leased line control = 20 meter.

  • Page 239

    Peripheral equipment 239 rs449: rs366: all balanced inputs and outputs (a and b) use balanced line signals according to v.11 (rs422) and single ended signals in accordance with v.10 (rs423). For balanced signals a "0"=low voltage is defined as terminal a positive with respect to terminal b. For unba...

  • Page 240

    Tandberg maestro mxp 240 all signals are electrically according to rs232. Cable length max: 5 meter x21:.

  • Page 241

    Peripheral equipment 241 all balanced inputs and outputs (a and b) use balanced line signals according to v.11 (rs422) and single ended signals in accordance with v.10 (rs423). For balanced signals a "0"=low voltage is defined as terminal a positive with respect to terminal b. For unbalanced signals...

  • Page 242: 5.1.4 Data

    Tandberg maestro mxp 242 5.1.4 data port the data port(s) are implemented as data communications equipment (dce). The connectors used are female 9-pin d-subs. The tandberg main camera is normally connected to data port 2 and pin number 4 provides 12v dc / 1 amps to the main camera. Otherwise the pin...

  • Page 243: 5.2 Document Camera

    Peripheral equipment 243 5.2 document camera a document camera can be used for showing text, diagrams and a variety of graphical material as well as small three-dimensional objects. How to use a document camera with your system: 1. Connect the document camera to the doc cam input, if available, on t...

  • Page 244: 5.3 Dvd / Vcr

    Tandberg maestro mxp 244 5.3 dvd / vcr dvd/vcr playback mono for playback, connect a cable between video out on the vcr and video in (vcr) on the system. Connect a cable between audio out on the vcr and the audio in (vcr) on the system. Choose vcr from the presentation menu to activate the vcr input...

  • Page 245: 5.4 Additional Cameras

    Peripheral equipment 245 5.4 additional cameras extra fixed cameras you can connect extra fixed cameras to your system, for example, a whiteboard camera. Connect the video output of the additional camera to one of the available video inputs on the system. Multiple controllable cameras attaching mult...

  • Page 246: 5.5 Additional Microphones

    Tandberg maestro mxp 246 5.5 additional microphones if your environment is such that you require more than one microphone for your room, e.G. You have a whiteboard at a distance from your table microphone, it is possible to connect additional microphones to your system. See appendix 4 for more infor...

  • Page 247

    Peripheral equipment 247.

  • Page 248: 5.6 The Tandberg Dnam and

    Tandberg maestro mxp 248 5.6 the tandberg dnam and speakers tandberg 6000 mxp profile, tandberg 6000 mxp, tandberg 7000 mxp, tandberg 8000 mxp and tandberg maestro the tandberg digital natural audio module, dnam*: the dnam audiosystem is built on two specially designed and separate modules; the dnam...

  • Page 249

    Peripheral equipment 249 tandberg 6000 mxp profile dnam configuration center speakers + integrated stereo speakers the dnam amplifier*: ƒ 3 x 50w continuous average center output power (load specified by dnam center speakers). ƒ 2 x 50w continuous average stereo output power (load specified by tandb...

  • Page 250

    Tandberg maestro mxp 250 the dnam loudspeaker cabinet (center speakers)*: ƒ 3-way center speaker system ƒ frequency range 50hz - 20khz ƒ 2 x 130mm low- and midrange loudspeakers, 8 ohms nominal, high quality ƒ 1 x 25mm dome tweeter, 6 ohms nominal, high quality ƒ crossover filtered audio signals rec...

  • Page 251

    Peripheral equipment 251 the mini-dnam loudspeaker cabinet*: the mini-dnam speaker cabinet specification: ƒ 2 * 15w stereo speakers, high quality ƒ frequency range 100hz - 20khz ƒ enclosed mdf speaker cabinet integrated stereo speakers**: ƒ 2 * 15w stereo speakers, high quality ƒ frequency range 100...

  • Page 252: 5.7 Stereo Speaker Kit

    Tandberg maestro mxp 252 5.7 stereo speaker kit note that the following applies only for systems with a stereo s/pdif output. The stereo speaker kit provides an pair of floor-standing loudspeakers in addition to the built-in dnam . Using these speakers will enable stereo functionality in your system...

  • Page 253

    Peripheral equipment 253.

  • Page 254: 5.8 Telephone Add-On

    Tandberg maestro mxp 254 5.8 telephone add-on the system has a built in audio bridge* that can bring in voice over ip (voip) telephony or normal telephone sites using isdn. Note that this requires a system with mixed audio output (audio from local and far end) and one audio input without integrated ...

  • Page 255: 5.9 Dual Monitor

    Peripheral equipment 255 5.9 dual monitor note that this requires a system with dual monitor video output. The dual monitor option consists of an additional monitor, bigger cabinet top-plate and associated cabling. The dual monitor can be used to show full screen selfview, snapshots and duo video. T...

  • Page 256

    Tandberg maestro mxp 256 5.10 xga monitors and projectors (optional) some tandberg systems can be delivered with optional single or dual tv/xga monitors. It can also be connected to any dvi/vga/pal or ntsc display. Note that this requires a system with minimum one dvi-i output..

  • Page 257: 5.11 Vesa Display Power

    Peripheral equipment 257 5.11 vesa display power management because of the tremendous amount of energy consumed by monitors when operating, the system will reduce power consumption and extend monitor lifecycle by suspending the (switch off) monitors and projectors when the system goes into sleep/sta...

  • Page 258: 5.12 Digital Monitor Power

    Tandberg maestro mxp 258 5.12 digital monitor power management dmpm is monitor power management applied over the digital dvi interface. Tandberg supports dmpm in software f2 and above. Six monitor power states are defined. Monitor on power state transmitter (tandberg codec) and receiver (monitor) ar...

  • Page 259: Data (Edid)

    Peripheral equipment 259 5.13 extended display identification data (edid) extended display identification data (edid) is a vesa standard data format that will allow the system to communicate its capabilities, including vendor information like the supported vga- formats and frequency range limits to ...

  • Page 260

    Tandberg maestro mxp 260 tested and verified monitors, edid & timing listed below are some of the monitors tandberg have tested and verified against: adi a715 dell w1700 dell w1900 eizo l367 eizo f730 ergoscan 400s hitachi cm640et hitachi cm769et ibm 9494-hbo ibm g97 ibm e74 ibm 6743-60n jvc lt-23x4...

  • Page 261: 6 Appendices

    6 appendices appendices: appendix 1: technical specification appendix 2: bandwidth information appendix 3: environmental considerations appendix 4: guidelines for setting up videoconferencing rooms appendix 5: security appendix 6: using the file system appendix 7: web interface appendix 8: connectin...

  • Page 262: 6.1 Appendix 1

    Tandberg maestro mxp 262 6.1 appendix 1 technical specification system components integrated 5" lcd display, wave ii camera, microphone, digital natural audio module (dnam), integrated cabling, cart bandwidth h.320 up to 2 mbps h.323 up to 4 mbps point-to-point sip up to 4 mbps up to 6mbps total mul...

  • Page 263

    Glossary 263 interlaced sif (352 x 480 pixels), natural video sif (352 x 240 pixels) 400p (528 x 400 pixels) native pal: 4cif (704 x 576 pixels), digital clarity interlaced cif (352 x 576 pixels), natural video cif (352 x 288 pixels) qcif (176 x 144 pixels) sqcif (128 x 96 pixels) decode only 448p (...

  • Page 264

    Tandberg maestro mxp 264 downspeeding programmable network profiles intelligent call management ho on isdn-pri facility maximum call length timer automatic spid and line number configuration (national isdn, gr-2941-core) softmux nato standard kg194 / kiv-7 encryptor support h.331 broadcast mode uri ...

  • Page 265: 6.2 Appendix 2

    Glossary 265 6.2 appendix 2 bandwidth information for tandberg endpoints model 8000mxp, 7000mxp 6000mxp, maestro bandwidth point to point isdn / ip standard: 768 / 3072 option: 1920 / 4096 standard: 768 / 3072 option: 1920 / 4096 multisite total: 3072kbps 4x768 video + 4 audio 3x1536 video + no audi...

  • Page 266

    Tandberg maestro mxp 266 4x768 video + no audio 4x512 video + 3 audio rate matching yes yes dual stream (duovideo / h.239) yes yes secure conference all bandwidths all bandwidths h.264 up to 2mbps up to 2mbps picture mode multisite vs, cp4, cp5+1 vs, cp4, cp5+1 model 990mxp / 990net mxp 880mxp / 880...

  • Page 267

    Glossary 267 model 770mxp 1000mxp bandwidth point to point isdn / ip standard: 768 (ip only) option: 128 / 768 standard: 768 (ip only) options: 128 / 768, 384 / 768 multisite not available not available rate matching not available not available dual stream (duovideo / h.239) yes yes secure conferenc...

  • Page 268: 6.3 Appendix 3

    Tandberg maestro mxp 268 6.3 appendix 3 environmental considerations this section explains how to carry out basic adjustments and simple tests to ensure that you send and receive the best possible image and audio quality when using your system. Iris control and lighting by default the system camera ...

  • Page 269: 6.4 Appendix 4

    Glossary 269 6.4 appendix 4 guidelines for setting up videoconferencing rooms the following are a set of guidelines to consider when either building a videoconferencing room, or using an existing room for videoconferencing. Lighting: ƒ low contrast desired for light intensity. No dark spots. ƒ inten...

  • Page 270: 6.5 Appendix 5

    Tandberg maestro mxp 270 6.5 appendix 5 security the system has several features both to protect from unauthorized use and system access: access code: when access code is enabled, the user will be asked to enter an access code before he/she is able to make a call. The system will verify if the enter...

  • Page 271

    Glossary 271 by setting an ip access password on the system, all access to the system using ip (telnet, ftp and web) requires a password. This password can be enabled from telnet or dataport using the command: ippassword . The default ip username and password is "tandberg". To remove this password, ...

  • Page 272

    Tandberg maestro mxp 272 backwards compatibility) with extended diffie hellman key distribution via h.320, h.323 and leased line connections. The tandberg aes implementation is validated as conforming to the advanced encryption standard (aes) algorithm, as specified in federal information processing...

  • Page 273: 6.6 Appendix 6

    Glossary 273 6.6 appendix 6 using the file system it is possible to access a file system within the tandberg system by using ftp: dos- window: ftp , or web- browser: ftp:// description of the different files: all.Prm all settings in the system (including directory) dir.Prm directory entries (up to 2...

  • Page 274: 6.7 Appendix 7

    Tandberg maestro mxp 274 6.7 appendix 7 web interface it is possible to access and maintain the system remotely via a local area network (lan) using a standard web-browser. Connect your system to a lan with a network cable. How to configure your system for web interface: 1. Openadministrator setting...

  • Page 275: 6.8 Appendix 8

    Glossary 275 6.8 appendix 8 (not available on all tandberg systems) connecting the system to pri/t1 using csu adapter connecting the system to the isdn network via the e1/t1-interface using an adtran t1 esf csu ace or equivalent csu, will allow up to 1.54 mbps connection. The e1/t1-interface must be...

  • Page 276: 6.9 Appendix 9

    Tandberg maestro mxp 276 6.9 appendix 9 connecting the system to the switched 56 network using telesync ts-256 sw56/isdn adapter connecting the system to the sw56 network using a telesync adapter is described below. There are different telesync adapters for different configurations of sw56 networks....

  • Page 277: 6.10 Appendix 10

    Glossary 277 6.10 appendix 10 connecting the system to isdn using nt1 network adapters connecting connect the first isdn cable from isdn 1 on the system to the s-interface on your first nt1 network adapter. Connect the other isdn cables to the appropriate nt1 network adapters. Connect the u-interfac...

  • Page 278: 6.11 Appendix 11

    Tandberg maestro mxp 278 6.11 appendix 11 (not available with set top systems) wave ii camera pinouts and connectors 8-pin rj (shielded modular jack): this connector is used for the power and control signals to the main camera. Pin-8 +12v (presence when connected in daisy chain) pin-7 gnd pin-6 gnd ...

  • Page 279

    Glossary 279 6-pin rj (modular jack): this connector is used when cascading cameras: control (out) signal and external camera detection. Note: it does not provide power for cascaded camera. Pri pinout pin-6 gnd pin-5 gnd pin-4 rxd (in) pin-3 txd (out) pin-2 presence (+12v in daisy chain) pin-1 gnd m...

  • Page 280

    Tandberg maestro mxp 280 dimensions front view: side view: rear view: underside view:.

  • Page 281: 6.12 Appendix 12

    Glossary 281 6.12 appendix 12 remote control (trc 3 / trc4) the tandberg remote control transmits ir-signals using the following parameters: protocol siemens sda2208 reference frequency 485khz address 4 & 7 ir wavelength 940nm ir carrier frequency 30khz.

  • Page 282

    Tandberg maestro mxp 282 remote control keycode map: button codes remote control (trc 3 / trc 4) button codes remote control (trc 3) remote control (trc 4) dec hex address button name dec hex address button name address button name 0 00 33 21 0 ok 0 ok 1 01 0 number 1 34 22 0 call 0 call 2 02 0 numb...

  • Page 283: 6.13 Appendix 13

    Glossary 283 6.13 appendix 13 cisco callmanager registration configuring an h.323 client on the callmanager 4.0 the registration of a h.323 client in callmanager is supported on the callmanager (ccm) 4.0 software and forward. 1. To configure the callmanager with an h.323 client, log on to the admini...

  • Page 284: 6.14 Appendix 14

    Tandberg maestro mxp 284 6.14 appendix 14 diagnostic tools for ip to use these tools, will require using a pc and setting up a telnet session towards the system. Q.931 to show q.931 trace during a call you need to issue the command ‘syslog on’. One can get traces for ras, q.931 and h.245 with this c...

  • Page 285

    Glossary 285 function port type gatekeeper discovery (ras) 1719 udp q.931 call setup 1720 tcp h.245* range 5555-5574 tcp video range 2326-2405 udp audio range 2326-2405 udp data/fecc range 2326-2405 udp multisite + duo video (*) note: while using multisite, if a site is disconnected and reconnected ...

  • Page 286: 6.15 Appendix 15

    Tandberg maestro mxp 286 6.15 appendix 15 system upgrade before starting the software upgrade of the tandberg mxp system, please make sure to have the new software file, (for instance s050000f30.Pkg) and the release key for this software available. Your tandberg partner will provide this for you. Al...

  • Page 287

    Glossary 287 figure 1 3. Enter the release key in the ‘release key’ field and press the ‘install software’ button..

  • Page 288

    Tandberg maestro mxp 288 a new page will now be displayed: figure 2 4. Type in the path to where the new software file is stored, or select the file by using the ‘browse’ button. 5. The progress for the sw upgrade can be tracked by pressing the ‘telnet’ link in the help text box before pressing the ...

  • Page 289

    Glossary 289 5. Type in your ip password (default is “tandberg”) as password. 6. Type ‘put and press enter. The new software file will now be uploaded to the tandberg mxp system. 7. When the software upload is complete, end the ftp connection to the tandberg mxp system by typing ‘bye’ in the dos pro...

  • Page 290

    Tandberg maestro mxp 290 figure 3 5. Enter the release key for the system to be upgraded in the ‘release key’ field. If no release key is given, the far end system will use the previously stored release key if possible. This will work when upgrading from a main release to a dot release. 6 make sure ...

  • Page 291: 6.16 Appendix 16

    Glossary 291 6.16 appendix 16 declaration of conformity.

  • Page 292: 7 Glossary

    Tandberg maestro mxp 292 7 glossary # 199 av1: external input for the tandberg/loewe monitor. 2nd monitor: the second monitor of your videoconferencing system. The second monitor is normally placed on the right side of the first monitor. 4cif: 4 times cif, 704x576 pixels 4sif: 4 times sif, 704x480 p...

  • Page 293

    Glossary 293 b bandwidth: decides the quality of the video call. High bandwidth gives high quality. C call control data triggered: uses txdata, rxdata and clock signals only. Use data triggered when no handshake signal is available. Call control leased line: is a non-dialing protocol and should be u...

  • Page 294

    Tandberg maestro mxp 294 diagnostics: allows testing of individual system components and displays the current system settings. Digital claritytf: participants enjoy presentations of exceptionally high quality resolution video. Disconnect site: as a chairman, you get the option to disconnect site. Di...

  • Page 295

    Glossary 295 g g.711: audio algorithm for normal quality audio (telephone quality, 3.1 khz) the system will always have g.711 enabled. G.722: audio algorithm for high quality audio (7 khz). G.722.1: audio algorithm for compressed high quality audio (7 khz) g.728: audio algorithm for compressed norma...

  • Page 296

    Tandberg maestro mxp 296 m main camera: your camera. Video input 1 max call length: this feature will automatically end both incoming and outgoing calls when the call time exceeds the length specified. Max channels: indicates the maximum number of channels the system is allowed to use on the e1/t1 i...

  • Page 297

    Glossary 297 non standard facility: the network provider may require service selection in your isdn configuration. Valid nsf codes are from 1 to 31. 0 will disable nsf service codes. Nr: noise reduction. Reduces constant background noise (e.G. Noise from air-conditioning systems, cooling fans, etc.)...

  • Page 298

    Tandberg maestro mxp 298 restart: restarts the system. Restore defaults: restores system settings to the factory defaults. Restricted call: a call to a 56 kbps network. By default the system will dial an unrestricted call (a call to a 64 kbps network) and downspeed to 56 kbps if necessary. S s-vhs: ...

  • Page 299

    Glossary 299 streaming source: select between local video and/or far end video to be streamed. Local and far end audio is always streamed. Streaming ttl/router hops: used for streaming data to limit how many routers the data should pass before it is rejected. Streaming video rate: defines the video ...

  • Page 300

    Tandberg maestro mxp 300 w wave ii camera: wide angle view camera - delivers the widest angle of view in the industry. Welcome menu: the welcome menu displays the main menu when you are outside a call. X xga: extended graphics array (1024 x 768).

  • Page 301: 8 Index

    8 index a access code....................................104, 129 add another call........................................50 additional microphone .............................245 administrator password...........................145 alert speaker ...........................................185 alert ...

  • Page 302

    Tandberg maestro mxp 302 pip placing ..............................................160 postpone 1 hour ........................................58 postpone 3 hours.......................................59 presentation presentation key............................82, 156 presentation menu.................