Tapworks AD11 User And Installation Manual - Programming
Programming the Ultra 9 Faceplate
Please Remember – Only use tablet or pellet salt in your softener!
13
Programming
(cont)
To increase or decrease the displayed number to your required
setting use the s or t buttons.
Once the required setting is displayed it may be set by pushing the
SET button once more.
SETTING ADDITIONAL FEATURES
SET THE RECHARGE TIME
Hold down the SET button for 3 seconds,
02:00AM recharge time will appear on
the screen.
Note: 2.00AM is chosen because any
household water used during recharge
will be replaced with hard water.
Consequently a time is required when
very little, if any, water will be used.
To select a different recharge time use the s or t buttons, to
adjust one hour at a time. Once the required setting is displayed it
may be set by pressing the SET button once more.
Note: Recharge will last for approximately 1 hour.
For maximum efficiency, we recommend
the factory setting – DY – is maintained.
This ensures the unit will automatically
control all recharges with intervals based
on water usage. If required, press s to
set a maximum time in days between
recharges. Each press of the s button
advances 1 day. When set, the unit will
recharge after the set number of days
since the last recharge, irrespective of water usage.
Press the SET button again, and
OFF-HEAVY BKWASH will be shown on
the display. For operation with this
unit the heavy back wash must
remain OFF. If this facility is ON,
press the t button to change. Press the
SET button to continue.
97 recharge will appear on the screen.
For operation with this unit, the
97 recharge feature must remain
OFF. If this facility is ON, press the t
button to change. Press the SET button to
complete the programming procedure.
02:00
RECHARGE TIME
RECHARGE
OFF
HEAVY BKWASH
97
RECHARGE