137
EMERGENCY SERVICE TIPS
Radiator fins clogged
• Clean it
Radiator water passage clogged
• Get it rectified
Thermostat defective
• Get it rectified
5.
Charging indicator
Battery not getting charged due
• Get the belt tension adjusted
continuously remains ON
to loose belt
Replace if broken
6.
Poor pickup
Accelerator cable loose
• Get it adjusted correctly
Air in the fuel system
• Remove the air
Clogged fuel filter
• Clean / Replace the element
Clogged air filter
• Clean / Replace the element
Clutch slipping/out of adjustment
• Get it rectified
Brakes grabbing
• Get it rectified
7.
Does not accelerate
Accelerator cable broken
• Get cable replaced
Fuel filter choked
• Replace
8.
Belt squeal
Loose belt
• Get belt tension adjusted
Belt glazed
• Get belt replaced
9.
Low engine oil pressure
Pressure transducer faulty,
• Do not run the engine
indicator 'ON' when engine is
and/or oil pump faulty
extensively . Take the car to
running eventhough engine oil
the nearest Authorised Service
level is within MAX/MIN marking
outlet & get the fault rectified
SR. NO.
PROBLEM OBSERVED
PROBABLE CAUSE
ACTION TO BE TAKEN