19
Models C303 & C314
Important: To the Operator
Syrup Out Indicator
AUTO
AUTO
AUTO
OUT
OK
OK
CO2-OK
WATER-OK
If the word “OUT” appears in one of the columns
below the word “AUTO”, it indicates a lack of syrup
or syrup pressure being supplied for the indicated
freezing cylinder. If the unit is out of syrup, the
product light will illuminate and a warning tone will
sound for that freezing cylinder. At this time, replace
the appropriate Bag-in-Box (BIB). As a safety
feature, the refrigeration system automatically stops
to prevent a freeze-up in the freezing cylinder
(barrel).
If a syrup out condition occurs on one barrel, that
barrel will enter the HOLD mode. During the HOLD
mode, refrigeration remains off, the beater continues
to run if the barrel is less than 50_F (10_C) and the
CO
2
solenoid for that barrel is closed to prevent the
dispensing of product. The other barrels will not be
affected.
CO
2
Out Indicator
AUTO
AUTO
AUTO
OK
OK
OK
CO2-OUT
WATER-OK
On the LCD, if the word “OUT” appears next to the
word “CO2” it indicates a lack of CO2 being supplied
to the freezer. The product light will also illuminate
and a warning tone will sound. This will continue
until the CO2 is replaced. If the CO2 is not replaced
within one minute, the machine will shut down.
Water Out Indicator
AUTO
AUTO
AUTO
OK
OK
OK
CO2-OK
WATER-OUT
On the LCD, if the word “OUT” appears next to the
word “WATER”, it indicates a lack of water being
supplied to the freezer. In addition, the product light
will illuminate and a warning tone will sound. This
will continue until the proper amount of water is
supplied to the freezer. If the water is not supplied
within one minute, the machine will shut down.
Audio Alarm Silencer
The audio alarm will be disabled if the ALARM
SILENCE key is pressed. If a fault condition occurs
or the system mode changes, the audio alarm will be
re-enabled automatically. If the audio alarm is
silenced for greater than 30 minutes without
correcting the fault, it will be re-enabled
automatically.
Product Not Ready Light
When the light is continuously illuminated (not
flashing) it indicates that there is a fault or an “OUT”
condition for syrup, water, or CO
2
.
When the light is flashing, it indicates that the
product is not at serving viscosity. This will occur
during the initial freeze down, a defrost cycle, and
during power saver modes.
Sampling Valve
The sampling valve is located behind the lower front
panel. The sampling valve is used to obtain a brix
reading.
Daily Procedures
The following procedure should be performed daily.
Remove the splash shield and front drip tray. Take
these parts to the sink and brush-clean them.
Re-install the parts onto the freezer. Use a clean,
sanitized towel and wipe down the front of the
machine, including the doors and spouts.