Taylor C303 Original Operating Instructions - page 8
3
Models C303 & C314
To the Installer
DO NOT operate this freezer with larger
fuses than specified on the unit data label. Failure to
follow this instruction may result in electrocution or
damage to the machine.
This unit is provided with an equipotential
grounding lug that is to be properly attached to the
rear of the frame by the authorized installer. The
installation location is marked by the equipotential
bonding symbol (5021 of IEC 60417-1) on both the
removable panel and the equipment's frame.
Stationary appliances which are not equipped with a
power cord and a plug or another device to
disconnect the appliance from the power source
must have an all-pole disconnecting device with a
contact gap of at least 3 mm installed in the external
installation.
Appliances that are permanently connected
to fixed wiring and for which leakage currents may
exceed 10 mA, particularly when disconnected or
not used for long periods, or during initial installation,
shall have protective devices such as a GFI, to
protect against the leakage of current, installed by
the authorized personnel to the local codes.
Supply cords used with this unit shall be
oil-resistant, sheathed flexible cable not lighter than
ordinary polychloroprene or other equivalent
synthetic elastomer-sheathed cord (Code
designation 60245 IEC 57) installed with the proper
cord anchorage to relieve conductors from strain,
including twisting, at the terminals and protect the
insulation of the conductors from abrasion.
CAUTION: THIS EQUIPMENT MUST BE
PROPERLY GROUNDED! FAILURE TO DO SO
CAN RESULT IN SEVERE PERSONAL INJURY
FROM ELECTRICAL SHOCK!
FOLLOW YOUR LOCAL ELECTRICAL CODES!
Beater Rotation
Beater rotation must be clockwise as
viewed looking into the freezing cylinder.
The following repairs must be
performed by an authorized Taylor Service
Technician.
To correct rotation on a single-phase unit, change
the leads on the capacitor in the watt-control
electrical box. (See wiring diagram for details.)
To correct the rotation on a three-phase unit,
interchange any two incoming power supply lines at
the freezer main terminal block only.
Initial Freezing Cylinder Cleaning
Due to the types of products used in FCB
equipment, it is imperative that the freezing cylinder
and the inlet tube be thoroughly brush cleaned,
rinsed, and sanitized before running any product.
Prepare a cleaning solution, using 2 oz. of liquid
detergent in 2 gallons of warm water. Using this
solution, brush clean the freezing cylinder and the
inlet tube. Rinse the freezing cylinder and the inlet
tube with clean water. Sanitize, using the sanitizing
procedures outlined in this Operator Manual, starting
on page 25.