Clearing Fault Tones
To clear the tone for any faults which have been
corrected, press the <-- -- arrow key. To see if there is
more than one fault, press the MENU/SEL key. When
the last fault is displayed, the control will return to the
OPERATOR MENU. To return to the main screen,
move the cursor to “A” and press the MENU/SEL key
again.
Listed below are the variable messages which will
appear, along with the corrective action:
1. NO FAULT FOUND: There was no fault found
in the freezer. Nothing will appear on the screen
after this variable message appears.
2. BEATER OVERLOAD: Press the reset button
firmly. Clear the tone per instructions in
“Clearing Fault Tones” on page 15.
3. CHK REFRIG SYS PSI: Place the power
switch in the OFF position. Wait 5 minutes for
the machine to cool. Place the power switch in
the ON position. Clear the tone per instructions
in “Clearing Fault Tones” on page 15.
4. COMP ON TOO LONG: Place the power
switch in the OFF position. Call service
technician. Clear the tone per instructions in
“Clearing Fault Tones” on page 15.
5. HOPPER THERM BAD: Place the power
switch in the OFF position. Call service
technician.
6. BARREL THERM BAD: Place the power
switch in the OFF position. Call service
technician.
7. GLYCOL THERM BAD: Place the power
switch in the OFF position. Call service
technician.
8. HOPPER OVER TEMP: The hopper
temperature has risen too high as follows. Clear
the tone per instructions in “Clearing Fault
Tones” on page 15.
a. The hopper temperature reaches 41_F.
(5_C.) or higher after a power failure.
b. The hopper temperature has not fallen below
41_F. (5_C.) by the end of the COOL phase
in the heat cycle.
9. BARREL OVER TEMP: The barrel temperature
has risen too high as follows. Clear the tone per
instructions in “Clearing Fault Tones” on
page 15.
a. The barrel temperature reaches 41_F. (5_C.)
or higher after a power failure.
b. The barrel temperature has not fallen below
41_F. (5_C.) by the end of the COOL phase
in the heat cycle.
10. POWER FAILURE: This message will appear
in the FAULT DESCRIPTION if a power failure
has occurred. Clear the tone per instructions in
“Clearing Fault Tones” on page 15.
Screen “C” is SET CLOCK. This screen will display the
current date and time. The date and time may only be
changed after the freezer has been manually brush
cleaned but before it has been placed in the AUTO
mode. Move the cursor under the number you wish to
change. Press the plus key to increase the number;
press the minus key to decrease the number. When
the desired time and date appears, press the
MENU/SEL key once to return to the OPERATOR
MENU.
SET CLOCK
10:21 AM
5/07/2002
-- --
<-- -- -- -- -- -->
+++
-- -- --
SEL
If an invalid date is entered, the following screen will
appear.
SET CLOCK
10:34 AM
02/30/2002
-- --
INVALID DATE
<-- -- -- -- -- -->
+++
-- -- --
SEL
When the MENU/SEL key is pressed, the controller
will return to the previous LCD screen to allow for
correction of the calendar entry. The controller will not
advance to the next screen until a valid date has been
entered. Once a valid date has been entered, pressing
the MENU/SEL key will display a the Daylight Saving
Time screen.
DAYLIGHT SAVING TIME
ENABLE
DISABLE
_ _ _ _ _
<-- -- -- -->
SEL