Taylor H63 Operating Instructions Manual - page 31
27
Model H63
Operating Procedures
090130
Rinsing
Step 1
Pour two gallons (7.6 liters) of cool, clean water into
the mix hopper. With the brushes provided, scrub the
mix hopper, mix level sensing probes, the outside of
the agitator housing, and the mix inlet hole.
Figure 30
Step 2
With a mix pail beneath the door spout, press the
WASH key.
Step 3
Open the draw valve on the freezer door. Drain all the
rinse water from the door spout, close the draw valve,
and press the WASH key cancelling the wash cycle.
Repeat this procedure until the rinse water being
drawn from the freezing cylinder is clear.
Hopper Cleaning
Step 1
Prepare a pail of an approved 100 PPM cleaning solu-
tion (examples: 2--1/2 gal. [9.5 liters] of Kay--5R or
2 gal. [7.6 liters] of Stera--SheenR). USE WARM WA-
TER AND FOLLOW THE MANUFACTURER’S
SPECIFICATIONS.
Step 2
Pour the cleaning solution into the hopper and allow it
to flow into the freezing cylinder.
Step 3
While the solution is flowing into the freezing cylinder,
brush clean the mix hopper, mix level sensing probes,
the outside of the agitator housing, and mix inlet hole.
Step 4
Press the WASH key and allow the cleaning solution
in the freezing cylinder to agitate for five minutes.
Step 5
Place an empty pail beneath the door spout.
Step 6
Open the draw valve on the freezer door and draw off
all the solution.
Step 7
Once the cleaner stops flowing from the door spout,
close the draw valve and press the WASH key
cancelling wash cycle.
Disassembly
Note: Failure to remove parts, brush clean and then
air dry these parts, will result in damage to the related
parts. These parts must be removed every 14 days or
the machine will lock--out and will not operate in the
AUTO mode.
BE SURE THE CONTROL SWITCH IS IN
THE OFF POSITION. Failure to do so may cause
injury from electrocution or hazardous moving parts.
Step 1
Lift out the torque arm. Disengage the draw arm from
the draw valve bracket and rotate the bracket to the
right.
Step 2
Remove the handscrews, freezer door, torque rotor
assembly, beater, scraper blades, and drive shaft from
the freezing cylinder. Take these parts to the sink for
cleaning.
Hint: If the guide bearing is not connected to the end
of the torque rotor shaft, it is still lodged in the beater
drive shaft. To remove the guide bearing, insert the
torque arm into the side hole of the drive shaft and
push the bearing forward.
Step 3
Remove the front drip tray and splash shield.