Taylor Made Environmental SMX Series Operation Manual - page 7
❖
❖
❖
❖
❖
English
7
adjust fan speed as the actual cabin temperature deviates from
the setpoint. As setpoint is approached, the fan speed
automatically slows. Once setpoint is reached, the compressor
cycles off and the fan keeps running on low speed.
Adjusting Brightness Control
With the SMX Online Net, the display brightness is adjusted
automatically according to cabin lighting conditions.
SMX II Only
Press the SET key once to display setpoint. Press SET a
second time to dim the data display. Press it a third time to dim
the display further. Press it again, and it returns to full bright-
ness.
Using The Humidity Control Routine
When engaged, the SMX humidity control routine automatically
turns the air conditioning system on at preselected intervals to
remove moisture from the air. The system is programmed at
the factory for average values. To change the factory settings,
see page 17.
To start the dehumidification program:
• Press OFF.
• Press COOL, HEAT and FAN keys simultaneously.
• The data display will flash HU, indicating that the program is
active.
• To halt the dehumidification program, press any key. The HU
message will stop flashing.
Safety Note
Whenever the SMX system is in the dehumidification mode, all
of the system safeguard controls remain active. If the seawater
flow fails or if line voltage falls below preset limits, the system
will automatically shut down. If AC power is interrupted, the
system will automatically resume operation in the dehumidifica-
tion mode when power is restored.