Thelin PARLOUR PELLET E.I. Owner's Manual - page 6
PARLOUR PELLET E.I.
PELLET HEATER
6
FIGURE 1 - OVERALL DIMENSIONS
FIGURE 2
FIGURE 3 - EXHAUST PIPE LOCATION
(REAR VIEW)
CLEARANCES
CHECK WITH LOCAL BUILDING OFFICIALS
FOR SPECIFIC CODE REQUIREMENTS. A
LISTED, TYPE "L" PELLET VENT PIPE IS
MANDATORY ON ALL INSTALLATIONS.
Clearance to Combustibles
Unit to Sidewall .......................... 5" (125 mm)
Unit to Backwall ...................... 1.5" ( 40 mm)
Unit to Diagonal Wall................. 5" (125 mm)
Unit to Alcove Ceiling ................ 1" ( 25 mm)
MOBILE OR MODULAR HOME
WARNING: Outside combustion air is mandatory
in mobile or modular installations. An outside air
inlet MUST be provided for combustion and
ventilation air. The air inlet must remain
unrestricted while unit is in use. Outside air
connection is located at the bottom, near the front of
the heater (see Figure 2). The Outside Air Bypass
Kit is mandatory for mobile and modular home
installations. The kit contains 2" flex tubing and a
box adapter. Do not hook up unit without this kit.
Secure stove to floor by drilling hole through back
two legs and using lag screw to attach to floor.
Putty hole after screws are in place. Unit must be
electrically grounded to steel frame of mobile home.
Also, the structural integrity of the mobile home
floor, walls, and ceiling/roof must be maintained.
Use only listed Type "L" pellet vent components for
installation. Failure to use listed pellet vent pipe
will void your warranty. See pipe manufacturer
instructions for installation instructions.
CAUTION: HOT WHILE IN OPERATION.
KEEP CHILDREN, CLOTHING, AND
FURNITURE AWAY. CONTACT MAY
CAUSE SKIN BURNS.