- DL manuals
- U-Line
- Refrigerator
- CLR1215
- User Manual
U-Line CLR1215 User Manual - page 50
USER GUIDE
Troubleshooting - Extended 4
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE •
SERVICE
Testing The Main Control
If the main control is suspected of being faulty, the
following procedure should be performed to verify main
control for functionality.
Relay & DC Outputs
One of the primary functions of the main control is to
operate the multiple relay and DC outputs during each
cycle. Verify proper operation of these relays using the
following procedure.
1. Enter “Relay Toggle” through the service menu.
NOTICE
Frequently toggling the compressor relay could
force the compressor into overload. The
compressor will automatically deactivate during
an overload and will remain deactivated until the
overload switch cools. This could take some
time. It is important to allow the compressor at
least 5 minutes off time between relay cycles.
2. Toggle the relay. Its related component should
activate / deactivate with the switching of the relay. If
it does not, test component.
Other Suspected Main Control Faults
If other components have been ruled out as being faulty
but the unit continues to have operating issues, it is most
likely due to a configuration error. Configuration errors
can be cleared by restoring the unit to its factory default
setting. Factory defaults may be restored through the
service menu.
CAUTION
!
Precautions must be taken while working with
live electrical equipment. Be sure to follow
proper safety procedures while performing tests
on live systems.
THERMISTORS
Thermistors are used for various temperature readings.
Thermistors provide reliable temperature readings using a
resistance which varies based on surrounding
temperatures. If a faulty thermistor is suspected it may
be tested using an accurate ohmmeter. In an ice water
bath (32°F) resistance should measure 16.1 kilohms.
5K OHMS @ 77°
16.1K OHMS - 32°F ambient
Check Voltage
At Wall Outlet
Verify Voltage At
Main Control
Voltage Input
Check Fuse F1
For Continuity
Replace
Reed Switch
Replace Main
Board
Replace
Fuse
Replace
Power Cord
Alert Customer
Of Power Failure
Is the Reed
Switch Operating
Properly?
Inspect
Customer UI
and Data Cable
Connect Test Display
Cycle Power And Check
For Operation
No Voltage
No Voltage
Voltage
Continuity
Operating
Not Operating
No Continuity
No
Yes
Voltage
Summary of CLR1215
Page 1
User guide safety • installation & integration • operating instructions • maintenance • service 1000 series • clr1215 • 15" clear ice maker right product. Right place. Right temperature. Since 1962..
Page 2
User guide u-line.Com contents safety • installation & integration • operating instructions • maintenance • service intro safety safety and warning disposal and recycling installation environmental requirements electrical cutout dimensions product dimensions side by side installation water hookup dr...
Page 3
User guide introduction 1 u-line.Com welcome to u-line congratulations on your u-line purchase. Your product comes from a company with over five decades and three generations of premium modular ice making, refrigeration, and wine preservation experience. U-line continues to be the american leader, d...
Page 4
User guide safety and warning 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service safety and warning notice please read all instructions before installing, operating, or servicing the appliance. Use this appliance for its intended purpose only and follow...
Page 5
User guide disposal and recycling 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service disposal and recycling danger ! Risk of child entrapment. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so child...
Page 6
User guide environmental requirements 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service environmental requirements this model is intended for indoor/interior applications only and is not to be used in installations that are open/ exposed to natural ele...
Page 7
User guide electrical 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service electrical warning ! Shock hazard — electrical grounding required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected. Never rem...
Page 8
User guide cutout dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service cutout dimensions prepare site your u-line product has been designed for either free- standing or built-in installation. When built-in, your unit does not require additional...
Page 9
User guide product dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service product dimensions 23-1/4" (591 mm) (includes 3/4" [20 mm] integrated panel) 34-1/8" to 35-1/8" (867 mm to 892 mm) 14-15/16" (379 mm) 3-9/16" (91 mm).
Page 10
User guide side-by-side installation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service side-by-side installation two units may be installed side-by-side. Cutout width for a side-by-side installation is the cutout dimension of a single unit times two. N...
Page 11
User guide water hookup 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service water hookup prepare plumbing please use the braided stainless steel water supply line which comes attached. The water line is fitted with a standard 1/4" (6.35 mm) compression f...
Page 12
User guide water hookup 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service 4. Turn on water and check for leaks. 5. Route water supply line in cable clamp and secure with screw..
Page 13
User guide drain 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service drain model numbers including “-00” or “-07” do not include a factory installed drain pump. Model numbers including “-40” or “-47” include a factory installed drain pump. Drain connecti...
Page 14
User guide drain 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service factory installed drain pump if your drain line will run up to a stand pipe, disposal or spigot assembly, or does not otherwise meet the requirements for a gravity drain, you may have o...
Page 15
User guide drain pump 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service drain pump notice please read this instruction completely before attempting to install or operate the unit. Improper hook-up can result in substantial property damage! If you are u...
Page 16
User guide drain pump 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service installation procedure warning ! To prevent accidental electrocution, make certain that the floor surfaces surrounding the unit are dry whenever power/electricity is removed from, ...
Page 17
User guide drain pump 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service warning ! The back panel serves as a guard. Do not put your hands inside the ice machine cabinet or attempt to touch any components except the discharge tube during testing. Cautio...
Page 18
User guide anti-tip bracket 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service anti-tip bracket 1. Slide unit out so screws on top of unit are easily accessible. 2. Remove the two screws from the opposite side of the hinge assembly using a t-25 torx dri...
Page 19
User guide general installation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service general installation leveling information 1. Use a level to confirm the unit is level. Level should be placed along top edge and side edge as shown. 2. If the unit is not...
Page 20
User guide integrated panel dimensions 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service integrated panel dimensions integrated panel notice due to differences in surrounding cabinetry the panel may not perfectly align with door. The procedure below is...
Page 21
User guide integrated panel installation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service integrated panel installation 1. Fully open door/drawer. 2. Starting at corner, pull gasket away from door/ drawer. 3. Continue to pull gasket free from gasket c...
Page 22
User guide integrated panel installation 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service 11.Remove clamps from door/drawer. Notice if panel requires additional adjustment after removing clamps, slightly loosen each screw and adjust panel as necessary...
Page 23
User guide grille - plinth installation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service grille - plinth installation removing and installing grille warning ! Disconnect electric power to the unit before removing the grille. When using the unit, the g...
Page 24
User guide door swing 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service door swing units have a zero clearance for the door to open 90°, when installed adjacent to cabinets. Stainless steel and black and white models require 2-1/8" (54 mm) door clearan...
Page 25
User guide door stop 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service door stop your u-line unit was shipped to you with the optional 90° pin(s). (models that are 15" wide include 1 pin. Models that are 24" wide include 2 pins.) the unit’s door will o...
Page 26
User guide door adjustments 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service door adjustments door alignment and adjustment align and adjust the door if it is not level or is not sealing properly. If the door is not sealed, the unit may not cool prope...
Page 27
User guide door adjustments 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service remove bottom hinge: 1. Remove bottom hinge from cabinet. 2. Remove corresponding screws on opposite side of cabinet. On some models there may be a nut behind one or both scr...
Page 28
User guide first use 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service first use all u-line controls are preset at the factory. Initial startup requires no adjustments. Notice u-line recommends discarding the ice produced during the first two to three ...
Page 29
User guide control operation 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service control operation up down light power clean alert led control function guide function command display/options on/off press and release unit will immediately turn on or off. ...
Page 30
User guide ice 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service ice ice cube thickness adjustment interval - as required notice ice thickness adjustment should only be made one increment at a time. Allow ice maker production to stabilize for 24 hours ...
Page 31
User guide sabbath mode 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service l sabbath mode u-line clear ice machine models are star-k certified and can be used during the sabbath. View a full list of star-k certified u-line units at www.Star-k.Org. To pr...
Page 32
User guide airflow and product loading 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service airflow and product loading notice the unit requires proper airflow to perform at its highest efficiency. Do not block the front grille at any time, or the unit wi...
Page 33
User guide cleaning 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service cleaning exterior cleaning vinyl clad (black or white) models clean surfaces with a mild detergent and warm water solution. Do not use solvent-based or abrasive cleaners. Use a soft ...
Page 34
User guide cleaning 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service notice use only u-line ice machine cleaner (part no. 37050, available from your dealer or direct from your local parts distributor. To locate a parts distributor near you, visit www....
Page 35
User guide cleaning 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service 9. When water begins flowing over the evaporator (approximately 3 minutes), pour 1 packet of clr cleaner into the water trough. The cleaning process will last approximately 45 minute...
Page 36
User guide cleaning condenser 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service cleaning condenser interval - every six months to maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser when necessary. Depe...
Page 37
User guide extended non-use 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service extended non-use vacation/holiday, prolonged shutdown the following steps are recommended for periods of extended non-use: 1. Remove all consumable content from the unit. 2. ...
Page 38
User guide troubleshooting 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service troubleshooting before calling for service if you think your u-line product is malfunctioning, read the control operation section to clearly understand the function of the con...
Page 39
User guide warranty 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service warranty u-line corporation limited warranty 1. U-line corporation (“u-line”) warrants each u-line product to be free from defects in materials and workmanship for a period of one ye...
Page 40
User guide warranty 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service of pool water, or directing a spray from a hose or similar device into and around the unit. 7. If a product defect is discovered during the applicable warranty period, you must promp...
Page 41
User guide wire diagram 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service wire diagram 42315_b wiring diagram green w/yellow black (hot) white (neutral) 1 10 control board (ground) waste water pump jumper plug without p60 waste pump green w/yellow (gro...
Page 42
User guide product liability 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service product liability important note: service or repairs must not be performed on any unit suspected to be involved in a property damage situation. If a unit has been altered or...
Page 43
User guide warranty claims 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service warranty claims the following information defines the parameters for filing a warranty claim: • valid serial number needed • valid model number needed • narda (or equivalent) ...
Page 44
User guide ordering replacement parts 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service ordering replacement parts parts may be ordered on-line, by fax or on the phone. See our contact information below: www.U-lineservice.Com (with service login) fax n...
Page 45
User guide system diagnosis guide 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service system diagnosis guide refrigeration system diagnosis guide system condition suction pressure suction line compressor discharge condenser capillary tube evaporator watt...
Page 46
User guide compressor specifications 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service compressor specifications danger ! Electrocution can cause death or serious injury. Burns from hot or cold surfaces can cause serious injury. Take precautions when s...
Page 47
User guide troubleshooting - extended 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service troubleshooting - extended specific errors and issues the technically advanced diagnostic capabilities of the electronic controls utilized on the 1200 and 2200 seri...
Page 48
User guide troubleshooting - extended 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service troubleshooting guide. Concern potential causes suggested remedy no display or interior lights unit may be in sabbath mode hold for 5 seconds to turn off sabbath mo...
Page 49
User guide troubleshooting - extended 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service refrigeration system diagnosis guide errors *all errors are logged in memory. *only door error is displayed on the display and has an audible signal. *for clear ice...
Page 50
User guide troubleshooting - extended 4 u-line.Com safety • installation & integration • operating instructions • maintenance • service testing the main control if the main control is suspected of being faulty, the following procedure should be performed to verify main control for functionality. Rel...
Page 51
User guide troubleshooting - extended 5 u-line.Com safety • installation & integration • operating instructions • maintenance • service thermistor failure always assure that all thermistor connections are clean and dry. Whenever opening a thermistor connection be sure to apply a fresh dab of die ele...
Page 52
User guide control operation - service 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service control operation - service ui button layout 1. Hidden button -accesses service menu -no led 2. Up button -increases temperature -navigates through service menu 3....
Page 53
User guide control operation - service 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service control quick guide electronic control descriptions except as noted, these functions are available on all models. 1. On/off the on/off mode allows the unit to be t...
Page 54
User guide control operation - service 3 u-line.Com safety • installation & integration • operating instructions • maintenance • service 6. Silent mode in some cases it may be requested for the unit to be shut down for short periods during meetings for example. To do this hold the down arrow and pre...
Page 55
User guide control operation - service 4 u-line.Com safety • installation & integration • operating instructions • maintenance • service service mode quick guide number service mode menu item to navigate/access 1 view thermistor #1 cabinet temp no offsets use up/down to access and light bulb key to ...
Page 56
User guide control operation - service 5 u-line.Com safety • installation & integration • operating instructions • maintenance • service service mode quick guide 1. Thermistor 1 — temperature this will show the pure thermistor reading with no offsets taken into account. When placed in ice water this...
Page 57
User guide control operation - service 6 u-line.Com safety • installation & integration • operating instructions • maintenance • service 22.Does not apply to this model. 23. Compressor runtime based on last cycle this will show the number of minutes the compressor has run in the prior cycle (or curr...
Page 58
User guide control defaults 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service control defaults * 115v models default to fahrenheit. 220-240v models default to celsius. ** offset and differential always expressed in °f. Default value fahrenheit/celsius*...
Page 59
User guide service mode 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service service mode service mode quick guide number service mode menu item to navigate/access 1 view thermistor #1 cabinet temp no offsets use up/down to access and light bulb key to vi...
Page 60
User guide service mode 2 u-line.Com safety • installation & integration • operating instructions • maintenance • service errors *all errors are logged in memory. *only door error is displayed on the display and has an audible signal. *for 68118 models, pump error is displayed via alert light with n...
Page 61
User guide thermistor 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service thermistors thermistors are used for various temperature readings. Thermistors provide reliable temperature readings using a resistance which varies based on surrounding temperatur...
Page 62
User guide defrost 1 u-line.Com safety • installation & integration • operating instructions • maintenance • service defrost these models have no defrost options..