    Www.U-lineservice.Com phone (414) 354-0300 • fax (414) 354-7905 service & parts tech lines phone (800) 779-2547 • fax (414) 354-5696 onlineservice@u-line.Com ©2008 u-line corporation 03/2008 dual zone models wine captain® models: 2275zwcs & 2275zwcol installation guide.

  • Page 2

    Www.U-lineservice.Com 2 03/2008 2275 dual zone wc model contents 1-follow safety precautions. . . . . . . . . . . . . . . . . . . . . . 2 safety alert definitions . . . . . . . . . . . . . . . . . . . . . . . 2 general precautions . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2-inspect and p...

  • Page 3

    03/2008 3 www.U-lineservice.Com 2275 dual zone wc model inspect and plan you have received a carton containing your 2275zwc or 2275zwcol with a package inside containing a use and care guide and a product registration card and an anti- tip bracket installation kit 2275zwcol units are shipped with an...

  • Page 4

    Www.U-lineservice.Com 4 03/2008 2275 dual zone wc model your u-line product has been designed for either free- standing or built-in installation. When built-in, your unit does not require additional air space for top, sides or rear. However, the front grille must not be obstructed and clearance is r...

  • Page 5

    03/2008 5 www.U-lineservice.Com 2275 dual zone wc model power supply the unit requires a grounded and polarized 115 vac, 60 hz, 15a circuit (normal household current). See electrical specifications. Environmental requirements many u-line models are designed to operate in harsh outdoor/marine environ...

  • Page 6

    Www.U-lineservice.Com 6 03/2008 2275 dual zone wc model 4. Remove the two door closer inserts from the existing bottom hinge and install as shown on the new bottom hinge (figure 8). Figure 8 5. Remove existing bottom hinge (3 screws) and remount on opposite side top. Remove hinge screw pin. 6. Remov...

  • Page 7

    03/2008 7 www.U-lineservice.Com 2275 dual zone wc model treatments are to be included in this installation, proceed to adjust door. Caution to prevent permanent damage to the inner liner of the dual-zone units, the rack wood trim must be removed from the unit for staining and/or finishing. Allow sta...

  • Page 8

    Www.U-lineservice.Com 8 03/2008 2275 dual zone wc model 2. Lightly scruff sand the wood trim with 280 or finer grit sandpaper. 3. Remove sanding dust with a clean, dry cloth. 4. The factory-applied seal is compatible with virtually all finishes. A low odor, water clean up, quick-drying finish such a...

  • Page 9

    03/2008 9 www.U-lineservice.Com 2275 dual zone wc model prepare the new overlay panel important the overlay door panel must not weigh more than 20 lbs. The thickness of the door panel must be 3/4". 1. Place a towel, or other similar, soft, non-marking material out on a flat clean surface. Be sure th...

  • Page 10

    Www.U-lineservice.Com 10 03/2008 2275 dual zone wc model 10. After gasket has been removed, place it on a flat, clean surface. 11. Secure door to the back of the wood overlay using tape on all four corners. Make sure all four edges are aligned (figure 17). Figure 17 12. Use the door frame holes as a...

  • Page 11

    03/2008 11 www.U-lineservice.Com 2275 dual zone wc model checking door alignment the unit’s door is aligned at the factory before shipment. However, its alignment could have been disturbed during shipment or during door panel installation. Important properly aligned, the door should be 1/8” below th...

  • Page 12

    Www.U-lineservice.Com 12 03/2008 2275 dual zone wc model caution electrical installation must observe all state and local codes. This unit requires connection to a grounded (three-prong), polarized receptacle that has been placed by a qualified electrician. The unit requires a grounded and polarized...

  • Page 13

    03/2008 13 www.U-lineservice.Com 2275 dual zone wc model anti-tip bracket installation 1. Locate the two anti-tip brackets included inside the unit.. 2. Place the unit into the area where it will be installed. Check the door, sides and top for a proper fit. Also test the make sure the door opens and...

  • Page 14

    Www.U-lineservice.Com 14 03/2008 2275 dual zone wc model 3. Recheck the leveling, from front to back and side to side. Make any necessary adjustments. The unit's top surface should be approximately 1/8" below the countertop. 4. Secure bracket into adjoining surface. Side-by-side installation 1. Remo...

  • Page 15

    03/2008 15 www.U-lineservice.Com 2275 dual zone wc model this page intentionally left blank..

  • Page 16

    ?2008 u-line corporation publication no. 30200e 03/2008 rev. A u-line corporation, located in milwaukee, wi, is a family operated manufacturer of built-in undercounter icemakers, combo ® icemaker/refrigerators, wine captain ® wine storage units, refrigerators, refrigerated drawers and refrigerator/f...