U-Line U-3018CLROL-00 Install Manual - page 5
Installation Guide
3
Ice Machines
Your U-Line product has been designed exclusively for a built-in
installation. When built-in, your unit does not require additional air
space for top, sides, or rear. However, the front grille must NOT be
obstructed and clearance is required for an electrical connection in
the rear.
NOTICE
• Unit can NOT be installed behind a closed cabinet door.
Electrical Specifications
WARNING
!
SHOCK HAZARD — Electrical Grounding Required.
• Never remove the round grounding prong from the plug
and never use a two-prong grounding adapter.
• Never use an extension cord to connect power to the
unit.
NOTICE
Electrical installation must observe all state and local codes.
This unit requires connection to a grounded (three-prong),
polarized receptacle that has been placed by a qualified
electrician.
The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A
power supply (normal household current). An individual, properly
grounded branch circuit or circuit breaker is recommended. GFCI
(ground fault circuit interrupter) is usually not required for fixed
location appliances and is not recommended for your unit because a
GFCI could be prone to nuisance tripping. However, be sure to
consult your local codes.
See Cut-Out Dimensions for recommended receptacle location.
Cut-Out Dimensions
3018CLR Series
Follow the cut-out drawing. The 18" width allows for ease in
installation and removal of the unit. 24" is the cabinet depth in most
installations.
3 Prepare Site
24"
18"
33-7/8"
to
34-7/8"
Preferred location for
3018CLR drain, water
line and receptacle is
in adjacent cabinet.
See Install Guide for
instructions.
5/8"