VADDIO CEILINGVIEW HD CCU Installation And User Manual - Appendix 4:
CeilingVIEW HD
Vaddio CeilingVIEW HD CCU Installation and User Guide - Document 341-768 Rev. A
Page 16 of 16
Appendix 3 (continued) Rear Panel Connections:
Power Supply Input:
36V 2.78 Amp power supply on a 5.5mm OD x 2.5mm ID connector.
RS-232 IN on RJ-45:
RS-232 Input from ProductionVIEW or other external RS-232 controller. NOTE: Daisy-chain control is not
supported with any of the CCU products.
RS-232 OUT / G/L Out on RJ-45:
RS-232 on Cat. 5 provide control to the CeilingVIEW Camera Module. NOTE: Genlock (G/L) is not
supported with CeilingVIEW CCU systems.
Tally on 2-pin Phoenix type connector:
Contact Closure lights LED on front panel allowing indication of which QCCU/camera combination is active in
a multi-camera/QCCU installation.
Unused Ports for the CeilingVIEW CCU Systems:
• Power - RJ-45
• G/L Input - BNC-F
• Camera Feature Switches: All of these switches should be in the down position.
• Y-Gain
• Distance
• Video Outputs
• Video RJ-45
Appendix 4:
Control Pin-outs for the Quick-Connect CCU
RS-232 IN Connector RJ-45
Pin
Signal - RS-232
1) Not
Used
2) Not
Used
3) Not
Used
4) Not
Used
5) Not
Used
6) GND
7)
RXD (from TXD)
8) TXD
(to
RXD)
RS-232 / G/L OUT Connector RJ-45
Pin
Signal - RS-232
1) Not
Used
2) Not
Used
3) Not
Used
4) Not
Used
5) Not
Used
6) GND
7) TXD (to RXD)
8)
RXD
(from
TXD)
9433 Science Center Drive, New Hope, MN 55428
Toll Free: 800-572-2011 ▪ Phone: 763-971-4400 ▪ FAX: 763-971-4464
www.vaddio.com
©2008 Vaddio - All Rights Reserved. Reproduction in whole or in part without written permission is prohibited. Specifications and pricing
are subject to change without notice. Vaddio, CeilingVIEW, EZCamera, Quick-Connect, WallVIEW, EZCable and PowerRite are
trademarks of Vaddio. All other trademarks are property of their respective owners. Document 341-768 Rev A.
+
G
12345678
12345678