VADDIO CEILINGVIEW HD CCU Installation And User Manual - page 7
CeilingVIEW HD
Vaddio CeilingVIEW HD CCU Installation and User Guide - Document 341-768 Rev. A
Page 7 of 16
Control Systems
If you are using a control system (i.e. Crestron®, AMX®, etc.) plug the CAT-5 cable from the RS-232 IN jack
on the Quick-Connect CCU to your control system using the CAT-5 to DB-9 serial adapter supplied with the
CeilingVIEW HD CCU System. Daisy Chain Note: Because the Quick-Connect CCU is an in-line device
between the RS-232 port of an external control device (e.g. ProductionVIEW HD, or a Crestron or AMX
control system) it is NOT compatible with daisy-chain. Each Quick-Connect CCU must have it’s own RS-232
control port to operate.
For commands to be sent through the Quick-Connect CCU to the camera, the CCU Control button on the
front of the Quick-Connect CCU must be turned off.
COMMAND LIST
Vaddio supplies this control specification for the CeilingVIEW HD CCU Document Camera.
Communication Specification:
Communication Speed: 9600 bps (default)
Start bit:
1
Stop bit:
1
Data bits:
8
Parity:
None
Communication Example:
For the VISCA Packet “8x 01 04 07 03 FF” (CAM_Zoom_Wide), “x” corresponds with the
number of the camera in the control chain
.
NOTE: This will always be 1 when using a
CCU.
VISCA Command Set
Command Set
Command
Command Packet
Comments
AddressSet
Broadcast
88 30 01 FF
IF_Clear
Broadcast
88 01 00 01 FF
CommandCancel
8x 2p FF
P: Socket No. (=1or2)
CAM_Power On
Off
8x 01 04 00 02 FF
8x 01 04 00 03 FF
Power ON/OFF
CAM_Zoom Stop
Tele(Standard)
Wide(Standard
Tele(Variable)
Wide(Variable)
Direct
8x 01 04 07 00 FF
8x 01 04 07 02 FF
8x 01 04 07 03 FF
8x 01 04 07 2p FF
8x 01 04 07 3p FF
8x 01 04 47 0p 0q 0r 0s FF
P=0 (Low) to 7 (High)
Pqrs: Zoom Position
CAM_Dzoom On
Off
Combine Mode
Separate Mode
Stop
Tele(Variable)
Wide(Variable)
Direct
8x 01 04 06 02 FF
8x 01 04 06 03 FF
8x 01 04 36 00 FF
8x 01 04 36 01 FF
8x 01 04 06 00 FF
8x 01 04 06 2p FF
8x 01 04 06 3p FF
8x 01 04 46 00 00 0p 0q FF
Digital Zoom ON/OFF
Opt/Dig Zoom Combined
Opt/Dig Zoom Separate
P=0(Low) to 7 (High)
Pq: D-Zoom Position
CAM_Focus Stop
Far(Standard)
Near(Standard)
Far(Variable)
Near(Variable)
Direct
Auto Focus
Manual Focus
Auto/Manual
One Push Trigger
Infinity
Near Limit
8x 01 04 08 00 FF
8x 01 04 08 02 FF
8x 01 04 08 03 FF
8x 01 04 08 2p FF
8x 01 04 08 3p FF
8x 01 04 48 0p 0q 0r 0s FF
8x 01 04 38 02 FF
8x 01 04 38 03 FF
8x 01 04 38 10 FF
8x 01 04 18 01 FF
8x 01 04 18 02 FF
8x 01 04 28 0p 0q 0r 0s FF
P=0 (Low) to 7 (High)
Pqrs: Focus Position
AF ON/OFF
One Push AF Trigger
Forced Infinity
Pqrs: Focus Near Limit Position