Vega VEGAMIP R61 Operating Instructions Manual

Manual is about: Receiving unit

Summary of VEGAMIP R61

  • Page 1

    Operating instructions vegamip r61 receiving unit - relay document id: 35786.

  • Page 2: Contents

    2 contents vegamip r61 • receiving unit 35786-en-140922 contents 1 about this document 1.1 function ........................................................................................................................... 4 1.2 target group ............................................................

  • Page 3

    3 contents vegamip r61 • receiving unit 35786-en-140922 safety instructions for ex areas pleasenotetheex-specificsafetyinformationforinstallationandop- eration in ex areas. These safety instructions are part of the operating instructions manual and come with the ex-approved instruments. Editing stat...

  • Page 4: 1  About This Document

    4 1 about this document vegamip r61 • receiving unit 35786-en-140922 1 about this document 1.1 function this operating instructions manual provides all the information you need for mounting, connection and setup as well as important instruc- tionsformaintenanceandfaultrectification.Pleasereadthisinf...

  • Page 5: 2  For Your Safety

    5 2 for your safety vegamip r61 • receiving unit 35786-en-140922 2 for your safety 2.1 authorised personnel all operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the plant operator. During work on and with the device the...

  • Page 6

    6 2 for your safety vegamip r61 • receiving unit 35786-en-140922 2.5 ce conformity thedevicefulfillsthelegalrequirementsoftheapplicableecguide- lines.Byaffixingthecemarking,vegaconfirmssuccessfultesting of the product. Only with class a instruments: the device is a class a instrument designed for us...

  • Page 7: 3  Product Description

    7 3 product description vegamip r61 • receiving unit 35786-en-140922 3 product description 3.1 configuration thetypelabelcontainsthemostimportantdataforidentificationand use of the instrument: • article number • serial number • technical data • article numbers, documentation with the serial number, ...

  • Page 8

    8 3 product description vegamip r61 • receiving unit 35786-en-140922 typicalapplicationsareoverfillanddryrunprotection.Withanoperat- ing distance of 100 m, vegamip 61 can be used, for example, in bulk solids silos with large diameters. Thanks to its simple and rugged measuringsystem,vegamip61isvirtu...

  • Page 9

    9 3 product description vegamip r61 • receiving unit 35786-en-140922 1 2 3 5 4 fig. 2: antenna versions 1 threaded version - internal horn antenna with ptfe cover 2 plastic encapsulated antenna with pp cover 3 horn antenna/316l 4 vegamip 61 with angled antenna extension 5 encapsulated horn antenna w...

  • Page 10

    10 3 product description vegamip r61 • receiving unit 35786-en-140922 • not in the open • dry and dust free • not exposed to corrosive media • protected against solar radiation • avoiding mechanical shock and vibration • storage and transport temperature see chapter "supplement - technical data - am...

  • Page 11: 4 Mounting

    11 4 mounting vegamip r61 • receiving unit 35786-en-140922 4 mounting 4.1 general instructions oninstrumentswithprocessfittingthread,thehexagonmustbetight- enedwithasuitablewrench.Fortheproperwrenchsizeseechapter "dimensions". Warning: the housing must not be used to screw the instrument in! Applyin...

  • Page 12

    12 4 mounting vegamip r61 • receiving unit 35786-en-140922 fig. 4: installation position (top view) the vegamip 61 requires a minimum product strength to detect dif- ferent products. Dependent on the medium there will be a respective product thick- ness. The properties of the medium are also depende...

  • Page 13

    13 4 mounting vegamip r61 • receiving unit 35786-en-140922 fig. 5: bulk solids vessel of plastic inmetalvessels,youhavetomountvegamip61onflangesor threaded sockets. It is also possible to measure through a window. In general, all products such as glass, ceramic and plastic are suitable as window mat...

  • Page 14

    14 4 mounting vegamip r61 • receiving unit 35786-en-140922 a c b fig. 6: installation in front of a vessel window a window of non-conductive material, for example, glass, plastic, etc. B mounting with condensation on the inner wall of the vessel c inspection glass fitting in general, the same as for...

  • Page 15

    15 4 mounting vegamip r61 • receiving unit 35786-en-140922 1 2 3 4 fig. 8: vegamip 61 - threaded version g1½ 1 polarisation marking 2 instrument hexagon 3 locknut 4 process seal 1. Insert the supplied process seal (1) before screwing it in 2. To screw vegamip 61 in, use the instrument hexagon (3) be...

  • Page 16

    16 4 mounting vegamip r61 • receiving unit 35786-en-140922 2 1 fig. 9: front flush installation 1 unfavourable installation - bulk solid can settle in front of the sensor 2 correct front flush installation ifafront-flushinstallationisnotpossible,youcanfilllongsocketswith a plastic or ceramic cylinde...

  • Page 17

    17 4 mounting vegamip r61 • receiving unit 35786-en-140922 2 1 2 2 1 1 fig. 10: front flush installation 1 plastic or ceramic material 2 fixing screw (if technically possible) in very abrasive products, vegamip 61 should be installed with a mounting adapter or in front of a suitable window. In this ...

  • Page 18

    18 4 mounting vegamip r61 • receiving unit 35786-en-140922 1 2 fig. 11: installation with vessel vibrations 1 anti vibration blocks or rubber buffers 2 window of non-conductive material, for example, glass, plastic, etc. Angle for an optimum switching signal, the two sensors must be adapted to each ...

  • Page 19

    19 4 mounting vegamip r61 • receiving unit 35786-en-140922 for a reliable function, the emitting and receiving unit must be in- stalled in the same polarisation direction. If several instrument pairs are installed in a vessel, the instrument pairscanbecodedbydifferentpolarisationpositionstoavoidthat...

  • Page 20

    20 4 mounting vegamip r61 • receiving unit 35786-en-140922 3 45° 1 2 fig. 14: possibilities for signal deflection 1 metal plate for signal deflection of the microwave signal 2 bent antenna extension 3 polarisation marking.

  • Page 21

    21 5 connecting to power supply vegamip r61 • receiving unit 35786-en-140922 5 connecting to power supply 5.1 preparing the connection always keep in mind the following safety instructions: warning: connect only in the complete absence of line voltage. • the electrical connection must only be carrie...

  • Page 22

    22 5 connecting to power supply vegamip r61 • receiving unit 35786-en-140922 fig. 15: connection steps 4 and 5 5. Insert the wire ends into the terminals according to the wiring plan information: solidcoresaswellasflexiblecoreswithwireendsleevesare inserteddirectlyintotheterminalopenings.Incaseoffle...

  • Page 23

    23 5 connecting to power supply vegamip r61 • receiving unit 35786-en-140922 3 2 1 fig. 16: wiring plan receiving unit - vegamip 61 (receiver) 1 relay output 2 relay output 3 voltage supply when connecting to a plc, the min. Switching capacity of the relay must be taken into account. If ncecssary, a...

  • Page 24: 6 Setup

    24 6 setup vegamip r61 • receiving unit 35786-en-140922 6 setup 6.1 adjustment elements thefiguresinbracketsrefertothefollowingillustration. 6 7 9 8 4 5 1 2 3 1 l n 3 (-) ( ) 4 5 6 7 8 2 + 3 4 5 6 7 8 fig. 18: electronics module mp6x r (receiving unit) - relay output 1 mode switch for selecting the ...

  • Page 25

    25 6 setup vegamip r61 • receiving unit 35786-en-140922 with these keys (7 and 8) you can adjust the switching point to the medium. Depending on the process, the sensitivity of vegamip 61 must be set higher or lower. Pressing the " "-->" key makes the sensor less sensitive. You can also adjust the s...

  • Page 26

    26 6 setup vegamip r61 • receiving unit 35786-en-140922 level switching status signal lamp - re- lay (yellow) failure of the supply voltage (max./min. Mode) any 5 3 4 (8) (6) (7) relaydeenergized fault any 5 3 4 (8) (6) (7) relaydeenergized red fault led lights up depending on the switching function...

  • Page 27

    27 6 setup vegamip r61 • receiving unit 35786-en-140922 c b a 2 3 1 1 1 fig. 35: indication strip 1 indication (led indication strip) 2 more sensitive - key to the left 3 less sensitive - key to the right a medium: plastics (pp, pvc …), solvents b medium: building materials (sand, stones …) c medium...

  • Page 28

    28 6 setup vegamip r61 • receiving unit 35786-en-140922 fig. 36: led indication strip - setting for products with strong signal damping if there is strong buildup during operation, adjustment with buildup is recommended.Ashortperiodofoperationisprobablysufficientto createbuildup,orbuildupcanbecreate...

  • Page 29

    29 6 setup vegamip r61 • receiving unit 35786-en-140922 with the two keys you can select the requested switching delay ac- cording to the following illustration. The switching delay can be adjusted in seven steps between 100 ms and 20 s. 200 ms 100 ms 500 ms 1 s 2 s 5 s 20 s fig. 38: adjust switchin...

  • Page 30

    30 7maintenanceandfaultrectification vegamip r61 • receiving unit 35786-en-140922 7 maintenanceandfaultrectification 7.1 maintenance if the device is used correctly, no maintenance is required in normal operation. 7.2 rectify faults the operator of the system is responsible for taking suitable meas-...

  • Page 31

    31 7maintenanceandfaultrectification vegamip r61 • receiving unit 35786-en-140922 should these measures not be successful, please call in urgent cases the vega service hotline under the phone no. +49 1805 858550. The hotline is also available outside normal working hours, seven days a week around th...

  • Page 32: 8 Dismount

    32 8 dismount vegamip r61 • receiving unit 35786-en-140922 8 dismount 8.1 dismounting steps warning: before dismounting, be aware of dangerous process conditions such as e.G. Pressure in the vessel or pipeline, high temperatures, cor- rosive or toxic products etc. Take note of chapters "mounting" an...

  • Page 33: 9 Supplement

    33 9 supplement vegamip r61 • receiving unit 35786-en-140922 9 supplement 9.1 technical data general data material 316l corresponds to 1.4404 or 1.4435 materials, wetted parts Ʋ processfitting-thread 316l Ʋ processfitting-flange 316l antenna instrument seal cover or wetted materials threaded version...

  • Page 34

    34 9 supplement vegamip r61 • receiving unit 35786-en-140922 measuring range 0.1 … 100 m (0.33 … 328 ft) beam angle 1) Ʋ threaded version - internal horn antenna (ptfe cover) 20° Ʋ plastic encapsulated antenna with pp cover 10° Ʋ horn antenna (316l) - ø 40 mm (1.575 in) 22° Ʋ horn antenna (316l) - ø...

  • Page 35

    35 9 supplement vegamip r61 • receiving unit 35786-en-140922 process pressure 2) Ʋ vegamip 61, threaded version - inter- nal horn antenna with ptfe cover -1 … 4 bar/-100 … 400 kpa (-14.5 … 58 psig) Ʋ vegamip 61, plastic encapsulated antenna with pp cover -1 … 2 bar/-100 … 200 kpa (-14.5 … 29 psig) Ʋ...

  • Page 36

    36 9 supplement vegamip r61 • receiving unit 35786-en-140922 for that reason the associated approval documents of these instruments have to be carefully noted. They are part of the delivery or can be downloaded under www.Vega.Com, "vega tools" and "instrument search" as well as under www.Vega.Com/do...

  • Page 37

    37 9 supplement vegamip r61 • receiving unit 35786-en-140922 vegamip 61 2 1 4 3 15 mm (0.59" ) 98 mm (3.86" ) 170 mm / 300 mm (6.69") / (1 1.81") 19 mm (0.75" ) ø 75 mm (2.95") ø 115 mm (4.53") 99,5 mm (3.92" ) ø 44 mm (1.73") fig. 41: vegamip 61, encapsulated antennas 1 encapsulated horn antenna wi...

  • Page 38

    38 9 supplement vegamip r61 • receiving unit 35786-en-140922 vegamip 61, mounting adapter (-40 … +450 °c) 24mm (0.95") x 61 mm (2.4") g2 a fig. 43: mounting adapter with ceramic cover for vegamip 61 with internal horn antenna, threaded version g1½ with ptfe cover (also with 1½ npt thread) x 150 mm (...

  • Page 39

    39 9 supplement vegamip r61 • receiving unit 35786-en-140922 9.3 industrial property rights vega product lines are global protected by industrial property rights. Further information see www.Vega.Com. Only in u.S.A.: further information see patent label at the sensor housing. Vega produktfamilien si...

  • Page 40: Index

    40 index vegamip r61 • receiving unit 35786-en-140922 index a abrasion 17 adjustment 25 area of application 7 b bending 19 buildup 15 c cable 21 cable screening 21 e electronics module 10, 31 emitting unit 8 encapsulated antennas 37 f faultrectification30 filling opening 12 functional principle 9 h ...

  • Page 41

    41 notes vegamip r61 • receiving unit 35786-en-140922.

  • Page 42

    42 notes vegamip r61 • receiving unit 35786-en-140922.

  • Page 43

    43 notes vegamip r61 • receiving unit 35786-en-140922.

  • Page 44

    Printing date: vega grieshaber kg am hohenstein 113 77761 schiltach germany 35786-en-140922 all statements concerning scope of delivery, application, practical use and operat- ing conditions of the sensors and processing systems correspond to the information available at the time of printing. Subjec...