Device Operation
13
Distance to line is the perpendicular distance from the SC-1 to the user defined start-line of the SC-1 in
meters. The distance is calculated off of the GPS unit latitude and longitude measurements.
Button Locking and Unlocking
The Velocitek SC-1 uses touch sensors to accept user input. Splashing water can trigger the touch
sensors. To prevent the device from being inadvertently controlled by splashing water the device locks,
or does not accept button inputs, when the indicated speed exceeds the
speed lock value
. At speeds
below the speed lock value, the buttons are unlocked and will accept user input. The lock feature can
be customized by connecting the SC-1 to a PC. By default the locking is enabled with a speed lock value
of 2.0 knots.
Clearing Start-line
Start-line end locations are cleared every time the SC-1 is powered off or disconnected from a computer.
Clearing the Maximum Speed
Both instantaneous and 10 second maximum speeds are cleared from memory every time the SC-1 is
powered off or disconnected from a computer.
Device Settings
Device settings allow you to customize the SC-1 behavior. The settings are configurable by connecting
the SC-1 to a PC. Following are the available device settings.
Speed Displayed In
The speed can be displayed in knots, mph, km/s and m/s. The default setting is knots.
Magnetic Declination
Input the local magnetic declination to adjust the GPS compass so magnetic heading is displayed. Set
magnetic declination to 0 to display true heading. By default the SC-1 displays true heading.
Speed Lock Enable
The speed lock can be enabled or disabled. By default the speed lock is enabled.
Speed Lock Value
The speed lock value can be edited. By default the speed lock is set to 2.0 knots.