3. PREPARE THE INSTALLATION
(CONT’D)
4. PREPARE THE HOOD
NOTE:
If the bottom of the cupboard is recessed, attach wood strips (not included), as shown below, in order to properly
install the range hood (
A
) or charcoal filter unit (if need be) to the cabinet (
B
). The wood strips must be as thick as
recess.
Remove both filters from the hood. Disassemble the adaptor/damper (
A
) from the hood.
NOTE:
Depending on the hood model, the adapter/damper can be located on top of the hood (for double blower hoods) or
inside the hood (for single blower hoods). In this last case, the bottom panel (
B
) must be removed to access the
adapter/damper. Refer to figures below.
D
OUBLE
BLOWER
HOOD
:
S
INGLE
BLOWER
HOOD
:
HO0002A
2 ”
3
8
HD0033
A
A
B
Cut-out the openings for duct (
A
) and power cable (
B
), in cabinet or wall, according to the direction of discharge chosen.
See figures below.
H
ORIZONTAL
DISCHARGE
:
V
ERTICAL
DISCHARGE
:
C
L
HD0150A
3½”
5¼” 5¼”
B
1¼” dia.
A
7
8
”
11
1
8
”
HO0055
A
B
HO0057
C
L
¾
”
3
¾
”
5¼
”
5¼
”
1
¼
”
HD0151A
A
CABINET BOTTOM
B
3
8
”
1½
”
10½
”
- 5 -
If it is not done yet, remove the bottom panel from the hood and set aside. Punch out the appropriate electrical knock-out hole.
CAUTION
Never use a hammer and a screwdriver to
punch out the vertical or horizontal
discharge knock-out, because this will
damage the hood internal parts.
HD0152