VENOM P1 Instruction Manual And Tuning Manual - page 5
5
STEP #1. Enter the programming mode.
Switch on the transmitter. Move the throttle trigger to the Full throttle position and then connect the battery pack to the
ESC.
Wait for 2 seconds, the motor emits “Beep-Beep” tone.
Wait for 5 seconds, the motor emits a special musical tone noting that the program mode has been entered.
STEP #2. Select a tuning category.
You will hear 4 groups of repeating “Beep” tones when you enter the programming mode. If you move the throttle to
the neutral position within 3 seconds after one of the 4 tones, this tuning catagory will be selected.
1. “Beep”
Running Mode
2. “Beep-Beep”
Lipo Cells
3. “Beep-Beep-Beep”
Low Voltage Cutoff Threshold
4. “Beep-Beep-Beep-Beep”
Timing
STEP #3. Choose the new value for the tuning category.
After entering a tuning category you will hear several repeated tones. To set the desired value, move the throttle
trigger to the Full throttle position after you hear the tone. A special musical tone will emit, signifying the value has
been chosen and saved in the ESC.
NOTE:
If you keep the throttle trigger in the Full throttle position you will go back
to step #2 and you can select a different tuning category. If you move the throttle to the neutral position within 2
seconds you will exit program mode.
STEP #4 Exit program mode.
There are 2 methods to exit the program mode:
Method 1
In Step #3, after choosing the value the motor will emit a special musical tone. Move the throttle to the neutral position
within 2 seconds and you will exit program mode.
Method 2
Disconnect the battery pack from the ESC to force quit and exit the program.
CAUTION: LOW VOLTAGE CUT OFF
Do not use “NO PROTECTION” when using LiPO battery packs. Monitor the battery pack temperatures after
each run. Do not allow the battery pack temperatures to exceed 120º F/ 52º C while in use. Select a higher low
voltage cutoff setting to help reduce the temperature of the battery packs. It is OK to use “NO PROTECTION”
when using NiCD or NiMH battery packs.
Tuning
Category
Running
Mode
Lipo
Cell #
Low
Voltage
Cutoff
Timing
Forward
Only
Auto
Calculate
No
Protection
0º
Forward &
Backward
2
Cells
2.8V/Cell
3.75º
3
Cells
3.0V/Cell
7.5º
4
Cells
3.2V/Cell
11.25º
5
Cells
3.4V/Cell
15º
6
Cells
18.75º
22.5º
26.25º
BEEP TONES
“B”
1 Short Beep
“BB”
2 Short Beeps
“BBB”
3 Short Beeps
“BBBB”
4 Short Beeps
“Beep-”
1 Long Beep
“Beep-B”
1 Long
1 Short Beep
“Beep-BB”
1 Long
2 Short Beeps
“Beep-BBB”
1 Long
3 Short Beeps
ESC SETUP CONT.
ESC SETUP CONT.