Venue Lighting Effects THINTRI 38 LED Owner's Manual - Setup
7
www.venuelightingeffects.com
SETUP
AC POWER
The ThinTri 38/64 have an auto-ranging power supply and it can work with an input voltage range of 100 to 240
VAC, 50/60 Hz. To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the
current value listed on the product’s back panel, or refer to the product’s specifications chart. The listed current
rating indicates the product’s average current draw under normal conditions.
Always connect the product to a protected circuit (circuit breaker or fuse). Make sure the
product has an appropriate electrical ground to avoid the risk of electrocution or fire.
To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely
disconnect the product from power via breaker or by unplugging it.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat
or dimmer channel serves only as a 0 to 100% switch.
FUSE REPLACEMENT
1. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
2. Pry the fuse holder out of the housing.
3. Remove the blown fuse from the holder and replace with a fuse of the
exact same type and rating.
4. Insert the fuse holder back in place and reconnect power.
Disconnect the product from the power outlet before replacing the fuse.
Power Linking
The product provides power linking via the Edison outlet located in the back of the product.
Please see the diagram below for further explanation.
1
st
Product
2
nd
Product
3
rd
Product
You can power link up to 31
ThinTri-38 or 14 ThinTri-64
products on 120 VAC.
Fuse Holder