VOKERA Mynute 28e User Instructions - page 7
7
Mynute
Example
Group of days
On
Off
Commands
used
Mon. to Fri.
06.00
09.00
2
Mon. to Fri.
16.00
21.00
2
Sat. & Sun.
08.30
10.30
2
Sat. & Sun.
17.00
23.00
2
Total
8 used
Commands ‘free’
12 unused
5.2.1
BEFORE PROGRAMMING
Gently press and release the ‘Res.’ button with a
pencil or similar, this will clear the memory of all
information. This should only be done when you
want to change or insert a complete new pro-
gramme.
5.2.2
SETTING THE TIME OF DAY
The ‘real time’ clock has to be set to the actual
day of the week and time of day, to do this:
●
Press and hold the
button (see fig. 6).
●
Press the ‘Day’ button until the actual day shows
in the display (1= Monday, 2= Tuesday, 3=
Wednesday, etc.).
●
If setting the clock during ‘British summertime’
press the ‘+/-1h’ button once (use a pencil or
similar).
●
Press the ‘h’ button until the actual hour is
shown in the display.
●
Press the ‘m’ button until the actual minutes
are showing in the display.
●
Now release the
button.
●
The ‘:’ symbol between the hours and minutes
display will start to flash, this indicates that the
clock is now keeping time (see fig. 6).
5.2.3
ENTERING
(on) COMMANDS
●
Repeatedly press the Prog. Button until the —
:— symbol appears in the clock display (see
fig. 7).
●
Press the Day button until the desired group of
days or desired day is shown.
●
Press the ‘h’ button until the desired hour for
switching the boiler on is shown.
●
Press the ‘m’ button until the desired minutes
are shown.
●
Press the Select button until the
symbol is
shown (see fig. 8).
●
Press the
button.
5.2.4
ENTERING
(off) COMMANDS
●
Repeatedly press the Prog. Button until the —
:— symbol appears in the clock display (fig. 7).
●
Press the Day button until the desired group of
days or desired day is shown.
●
Press the ‘h’ button until the desired hour for
switching the boiler off is shown.
●
Press the ‘m’ button until the desired minutes
are shown.
●
Press the Select button until the
symbol is
shown (see fig. 9).
●
Press the
button.
Once the programming has been completed you
will have to press the Select button – once only –
to the
(on) position if the boiler has been
programmed to be ‘on’ at that particular time.
5.2.5
ADVANCING OR LOCKING PROGRAMME
COMMANDS
By pressing the Select button you can advance
the time clock to the next command setting (from
‘on’ to ‘off’ or ‘off’ to ‘on’) or lock the time clock to
a particular command (‘on’ continuously or ‘off’
continuously).
●
- ON
●
- OFF
●
[
] – ON CONTINUOUSLY
●
[
] – OFF CONTINUOUSLY
NOTE
The actual time can be changed to account for
British summertime by simply pressing then re-
leasing the +/- 1h button.
HELPFUL HINTS
●
You can check and/or alter the programme
settings at any time by pressing the Prog button.
●
The number of unused ‘commands’ can be
checked by pressing the Prog button until FR
is displayed alongside the number of unused
commands.
●
In the event of a power failure, the clock has a
battery back-up. The programme will be held
in the memory for approximately 2 weeks.
Charging time is 70 hours.
●
Take a note of the settings you have pro-
grammed, as local power surges can some-
times reset the memory of the clock.
Fig. 5
Fig. 6
Fig. 9
Fig. 7
Fig. 8