MAINTENANCE
Maintenance schedule
Check all external screw connections for tight fit approx. 8 hours after first operation.
Parts
Maintenance jobs
Maintenance interval
Air filter
Check for external damage and tight
daily
fit.
Check foam and filter insert clean or replace if
necessary.
Fuel
Check tank lid for tightfit, replace if
necessary.
Engine oil
Check oil level, top up if necessary.
Other parts
Check cutting disc for damages and correct tightenning
- change and or adjust if necessary. Pay attention
to the directional arrow on the disc.
Control smooth working of the height adjustment.
Control water supply.
Belts
Check tension and wear – replace if necessary.
weekly
Engine oil
First oil change.
20 hours
Air filter
Clean
.
50 hours
Ignition system
Clean spark plug, check spark plug gap 0,7 mm.
100 hours
Engine oil
Furhter oil changes.
Valve clearance
Check, set - 0,15 mm intake valve, 0,20 mm exhaust
300 hours
valve.