Waldorf RN8110GE Installation and operation manual - page 23
Gas Conversion and Specifications
21
NOTE: Ensure pilot burner and thermocouple are
correctly located and pilot burner aligns
with main burner ignition port. (Refer to
figure opposite for correct fitting and
alignment dimensions).
Re-connect gas supply tube to pilot burner.
Refit RH main fire brick.
Refit 2 front fire bricks.
Refit 2 half plate castings - ensure they are
correctly interlocked.
Refit centre casting.
Refit front control panel and control knob.
Low Fire Adjustment
NOTE: Adjust low fire adjustment screw on gas control valve to as
shown in ‘Gas Specifications Tables’ at rear of this section.
1.
Light main burner and check flame size on simmer (LOW) position.
NOTE: 'Low Fire Screw' should be sealed with coloured paint on
completion of low fire adjustment.
Gas Regulator
NOTE: The gas regulator supplied is
convertible between Natural
Gas and LP Gas, but it’s outlet
pressure is fixed ex-factory
and is NOT to be adjusted.
Gas Type Identification Label
On completion of gas conversion, replace gas type identification label located at:-
- Rear of appliance, above gas connection.
- Beside the rating plate.
Commissioning
Before leaving the installation;
1.
Check all gas connections for leakage using soapy water or other gas detecting equipment.
2.
Carry out a ‘Commissioning’ check of appliance as shown in Installation Section of this manual.
3.
Ensure any paint sealed components are re-sealed on completion of adjustments.
Low Fire
Screw
NOTE, Pin rotated
for Natural Gas
NOTE, Pin rotated
for LPG
Main Burner
Ignition Port
Pilot Burner
Thermocouple
18± 2.0
2± 2.0
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.
Warning