Waldorf RN8110GE Installation and operation manual - page 24
Gas Conversion and Specifications
22
Gas Specifications
- Non CE Only (Australia / New Zealand):
- CE Only:
Appliance Classification
Category:
II
2H3P.
Flue Type:
A
1.
* Measure burner operating pressure at target top hob manifold test point with target top burner
(Inner and outer ring) operating at full setting. Operating pressure is ex-factory set through
appliance regulator and not to be adjusted, apart from when carrying out gas conversion, if
required. (Refer to details in this section for information).
Natural Gas
LP Gas (Propane)
Main Burner Injector (Inner Ring)
Ø 1.70 mm
Ø 1.10 mm
Main Burner Injector (Outer Ring)
Ø 2.60 mm
Ø 1.55 mm
Pilot Burner Injector
0.35
0.25
Burner Aeration Screw X (Inner)
25 mm
25 mm
Burner Aeration Screw Y (Outer)
28 mm
28 mm
Low Fire Adjustment
2
1
/
2
turns out (ccw)
1 turn out (ccw)
Operating Pressure
1.0 kPa (*)
2.6 kPa (*)
Gas Regulator Cap Screw
Natural Gas
(G20)
Propane
(G31)
Main Burner Injector (Inner Ring)
Ø 1.70 mm
Ø 1.10 mm
Main Burner Injector (Outer Ring)
Ø 2.60 mm
Ø 1.55 mm
Pilot Burner Injector
0.35
0.25
Burner Aeration Screw X (Inner)
25 mm
20 mm
Burner Aeration Screw Y (Outer)
28 mm
25 mm
Low Fire Adjustment
2
1
/
2
turns out (ccw)
1¾ turn out (ccw)
Operating Pressure
9.9 mbar (*)
26.8 mbar (*)
Gas Regulator Cap Screw