Waldorf RN8110GE Installation And Operation Manual - page 10
8
Gas Connection
NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY AN AUTHORISED PERSON.
1.
It is essential that the gas supply is correct for the appliance to be installed and that adequate supply
pressure and volume are available. The following checks should therefore be made before
installation:-
a. Gas Type the appliance has been supplied for is shown on the
coloured stickers located above the gas connection and next to
the rating plate. Check that this is correct for the gas supply
the appliance is being installed for. The gas conversion
procedure is detailed in this manual.
b. Supply Pressure required for this appliance is shown in the
“Specifications” section of this manual. Check the gas supply to
ensure adequate supply pressure exists.
c. The Input Rate of this appliance is stated on the Rating Plate
and in the “Specifications” section of this manual. The input
rate should be checked against the available gas supply line
capacity. Particular note should be taken if the appliance
is being added to an existing installation.
NOTE: It is important that adequately sized piping runs directly to the connection joint on the
appliance with as few tees and elbows as possible to give maximum supply volume.
2.
Fit the gas regulator supplied, into the gas supply line as close to the appliance as possible.
NOTE: The gas pressure regulator provided with this appliance is convertible between Natural Gas
and LPG as per the ‘Gas Conversion Section’ in this manual.
Ensure the regulator is converted to the correct gas type that the appliance will operate on.
The regulator outlet pressure is fixed ex-factory for the gas type that the
regulator is converted to and it is NOT to be adjusted.
The regulator connections are
3
/
4
" BSP female.
The connection to the appliance is
3
/
4
" BSP male.
(Refer to the ‘Specifications’ section for the gas supply location dimensions).
NOTE: A Manual Isolation Valve must be fitted to the individual appliance supply line.
3.
Correctly locate the appliance into its final operating position and using a spirit level, adjust the legs
so that the appliance is level and at the correct height.
4.
Connect the gas supply to the appliance. A suitable joining compound which resists the breakdown
action of LPG must be used on every gas line connection, unless compression fittings are used.
5.
Check gas operating pressure is as shown in the ‘Specifications’ section.
6.
Check all gas connections for leakages using soapy water or other gas detecting equipment.
NOTE: The burner operating pressure is to be measured at
the manifold test point with both burners operating
at ‘Full’ setting.
7.
Turn off the mains gas supply and bleed the gas out of
the appliance gas lines.
8.
Turn on the gas supply and the appliance.
9.
Verify the operating pressure remains correct.
Rating Plate
Location
Fig 2
Installation
WARNING:
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.
Fig 3
Manifold Test
Point
gpd.sunwayinfo.com.cn
gpd.sunwayinfo.com.cn