I n s t a l l a t i o n a n d o p e r a t i o n m a n u a l gas cooktops series rn8200g rn8400g rn8600g rn8800g date purchased serial number dealer service provider 228605-21 for use in gb, ie & dk rnl8200g rnl8400g rnl8600g rnl8800g.
Manufactured by moffat limited christchurch new zealand international contacts australia moffat pty limited e.Mail: vsales@moffat.Com.Au main office: (tel) +61 (03) 9518 3888 (fax) +61 (03 9518 3833 service: (tel): 1800 622 216 spares: (tel): 1800 337 963 customer service: (tel): 1800 335 315 (fax):...
1 waldorf gas cooktops rn(l)8200g gas cooktop 300 mm wide. Rn(l)8400g gas cooktop 600 mm wide. Rn(l)8600g gas cooktop 900 mm wide. Rn(l)8800g gas cooktop 1200 mm wide. Introduction .............................................................................................. 2 specification ...........
2 introduction we are confident that you will be delighted with your waldorf gas cooktops, and it will become a most valued appliance in your commercial kitchen. To ensure you receive the utmost benefit from your new waldorf gas cooktops, there are two important things you can do. Firstly: please re...
3 specifications model numbers covered in this specification rn[1]8200g-[2]-[3] 2 open burners. Rn[1]8203g -[3] 300 mm griddle. Rn[1]8400g-[2]-[3] 4 open burners. Rn[1]8403g-[2]-[3] 2 open burners + 300 mm griddle. Rn[1]8406g -[3] 600 mm griddle. Rn[1]8600g-[2]-[3] 6 open burners. Rn[1]8603g-[2]-[3]...
4 specifications gas supply requirements - non ce only (australia / new zealand): - ce only: appliance classification category: ii 2h3p (20, 30 / 37). Flue type: a 1. * - the burner operating pressure is to be measured at the manifold test point with two burners operating at full setting. The operat...
5 dimensions bench models refer to page 9 for cooktop options = rating plate location for this option. R rn(l)8400g-b rn(l)8200g-b r rn(l)8600g-b rn(l)8800g-b.
6 dimensions cabinet base models rn8200g models - not available in cabinet base option. Rn(l)8400g-cb rn(l)8600g-cb r = rating plate location for this option. R rn(l)8800g-cb refer to page 9 for cooktop options.
7 dimensions leg stand models rn8200g models - not available in leg stand base option. Rn(l)8400g-ls refer to page 9 for cooktop options = rating plate location for this option. R r rn(l)8600g-ls rn(l)8800g-ls.
8 dimensions refrigerated base models rn8200g and rn8400g models - not available in refrigerated base option. Rn(l)8600g-rb rn(l)8800g-rb refer to page 9 for cooktop options = rating plate location for this option. R r.
9 dimensions cooktop options rn(l)8200g rn(l)8400g rn(l)8800g rn(l)8803g rn(l)8806g rn(l)8809g rn(l)8600g rn(l)8603g rn(l)8606g rn(l)8609g rn(l)8203g rn(l)8403g rn(l)8406g note: • rn8200g models are only available in bench model (-b) option. • rn8400g models are available in bench model (-b), cabine...
10 installation requirements note: • it is most important that this cooktop is installed correctly and that operation is correct before use. Installation shall comply with local gas, health and safety requirements. • this appliance shall be installed with sufficient ventilation to prevent the occurr...
11 clearances note: only non-combustible materials can be used in close proximity to this appliance. * side clearances can be 50 mm when the adjacent surface is at least 100 mm below the cooking surface. Assembly note: • all models are delivered completely assembled. No further assembly is required,...
12 rear adjustable feet, fitting:- a. Secure the rear of the base tray to the rear cooktop legs by screwing the two adjustable feet supplied, into the base of the rear cooktop legs. B. Secure each adjustable foot, hand tight. Rear rollers, fitting:- a. Fit the rear leg securing bolts up through the ...
13 fitting adjustable feet / rear rollers to cabinet and refrigeration bases. Rear adjustable feet, fitting:- 1. Raise the appliance from the floor by approximately 75 mm using suitable lifting equipment (i.E. Palletiser / forklift) to allow the rear rollers to be removed. 2. Unscrew and remove the ...
14 gas connection note: all gas fitting must only be carried out by a qualified person. 1. Waldorf cooktops do not require electrical connection, as they function totally on the gas supply. 2. It is essential that the gas supply is correct for the cooktop to be installed and that adequate supply pre...
15 commissioning 1. Before leaving the new installation; a. Check the following functions in accordance with the operating instructions specified in the ‘operation’ section of this manual. • lighting the griddle. • light the open burners. (f - flame failure option). • light the open burners. (pf - p...
16 operation operation guide 1. Waldorf appliances have been designed to provide simplicity of operation and 100% safety protection. 2. Improper operation is therefore almost impossible, however bad operation practices can reduce the life of the appliance and produce a poor quality product. To use t...
17 open burners note: only cooking pans from size Ø 150mm to Ø 420mm are suitable fo use on these open burners. Flame failure option (f-models) lighting the open burners flame failure protection is incorporated for each burner by way of a thermo-electric system which will shut off the gas supply to ...
18 griddle these griddles are fitted with a pilot as a standard option and flame failure protection, which is incorporated by way of a thermo-electric system for each main burner. Flame failure protection will shut off the gas supply to that burner in the event that the pilot for that burner goes ou...
19 general clean the cooktop regularly. A clean cooktop looks better, will last longer and will perform better. Carbonised grease on the surface or between the trivets, griddle plates will hinder the transfer of heat from the cooking surface to the food. This will result in loss of cooking efficienc...
20 daily cleaning 1. The grease / spill tray(s) should be checked and emptied frequently to prevent overflow and spillage. Remove the spill tray(s) while still warm so that the grease is in a liquid state. Empty any grease from the trays and wash thoroughly in the same manner as any cooking utensil....
21 trivets and burners a. Remove the trivets from the top of the appliance, taking note that the trivets are manufactured with a lip on one edge, the lip must always be fitted to the outer edge (front and back) of the cooktop. (refer to fig 10 overleaf). B. Remove the burner cap and burner bowl (the...
22 note: it is imperative that the trivet supports are correctly re-fitted to the appliance to ensure that the trivets locate correctly and sit flush and level. Note that the trivet support front end, side rail profiles are different at either side and only one of the side rails seat into the cut-ou...
23 fault finding this section provides an easy reference guide to the more common problems that may occur during the operation of your equipment. The fault finding guide in this section is intended to help you correct, or at least accurately diagnose problems with your equipment. Although this secti...
24 conversion procedure note: • these conversions should only be carried out by qualified persons. All connections must be checked for leaks before re-commissioning the appliance. • adjustment of components that have adjustments/settings sealed (e.G. Paint sealed) can only be adjusted in accordance ...
25 11. Turn on the gas supply at the mains, re-light the burners and check the flame size on the simmer (low) position. Note: the right hand gas control valve supplies the rear burner and the left hand gas control valve supplies the front burner. 12. Refit all the trivet supports to the top of the a...
26 • for the refrigerated base model, the rating plate is located inside the right hand front panel and can be viewed through the upper grille. Refer to the ‘gas connection’ section and the ‘dimensions’ section. Pilot injectors a. Unscrew and remove the pilot injector plug from the fitting at the en...
27 griddle pilot burner a. With the gas supply turned off at the main supply, remove the griddle plate section by lifting it straight off the cooktop. B. Remove the gas control heat shield from around the griddle burner, this is just a push in fit. C. Disconnect the piezo igniter from the mounting b...
28 gas regulator note: the regulator supplied is convertible between natural gas and lp gas, but it’s outlet pressure is fixed ex-factory and is not to be adjusted. 1. Ensure that the gas supply is turned off. 2. Unscrew the hexagonal cap (23mm a/f) from the regulator. 3. Un-clip the plastic pin fro...
29 gas specifications - non ce only (australia / new zealand): - ce only: appliance classification category: ii 2h3p (20, 30 / 37). Flue type: a 1. * the burner operating pressure is to be measured at the manifold test point with two burners operating at the ‘high’ setting. The operating pressure is...
30 replacement parts list when ordering replacement parts, please quote the part number and the description as listed below. If the part required is not listed below, request the part by description and quote model number and serial number which is shown on the rating plate. Cooktops open burners 22...
31 general 227015 pot stand / trivet. 228881 spill tray 300 mm (rn8200g series). 228882 spill tray 600 mm (rn8400g / rn8800g series). 228883 spill tray 450 mm (rn8600g series). 227855 adjustable leg (84 mm - bench models). 227850 adjustable leg (flush stud) (150 mm - cb / rb models). 227851 adjustab...
32.
33.