Waldorf RN8410G Installation And Operation Manual - page 23
21
Gas Conversion and Specifications
NOTE, Pin rotated
for Natural Gas
NOTE, Pin rotated
for LPG
1.
Remove pilot and main injectors and replace with correct size injectors as shown in ‘Gas
Specifications Tables’ at end of this section.
2.
Refit the following:-
Re-connect pilot supply tube to pilot burner.
Refit main burner and sole plate(s).
Refit lower lintel.
3.
To replace the low fire screw in the static oven gas valve:-
Remove the oven control panel.
Remove low fire screw from gas valve and replace with
correct size low fire screw as shown in ‘Gas Specifications
Tables’ at end of this section.
NOTE: The 'Low Fire Screw' should be sealed with coloured
paint on completion of low fire adjustment.
Refit the oven control panel.
Gas Regulator
NOTE: The gas regulator supplied is convertible between Natural Gas and LP Gas, but it’s outlet
pressure is fixed ex-factory and is NOT to be adjusted.
Gas Type Identification Label
1.
On completion of gas conversion, replace gas type identification label located at:-
- Rear of appliance, above gas connection.
- Beside the rating plate.
Commissioning
1.
Before leaving the installation;
2.
Check all gas connections for leakage using soapy water or other gas detecting equipment.
3.
Carry out a ‘Commissioning’ check of the appliance as shown in the Installation Section of this
manual.
4.
Ensure any adjustments done to components that have adjustments / settings paint sealed are to be
re-sealed.
Low Fire Adjustment Screw
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.
Warning