Waldorf SN8200G Installation And Operation Manual - page 6
4
Specifications
Gas Supply Requirements
- Non CE Only (Australia / New Zealand):
- CE Only:
NOTE: * Measure burner operating pressure at manifold test point with both burners operating at
full setting. Operating pressure is ex-factory set and not to be adjusted, apart from when
converting between gases, if required. (Refer to ‘Gas Conversion’ section for details).
Gas Connection
Gas supply connection point is located at the back, 128mm from right hand side of appliance and
entered from beneath appliance.
Connection is ½ BSP male.
Natural (G20)
Propane (G31)
Heat Input (Gross)
Nominal
8.8 kW
8.8 kW
Reduced
3.6 kW
2.6 kW
Gas Rate
Nominal
0.84 m
3
/hr
0.63 kg/hr
Reduced
0.34 m
3
/hr
0.19 kg/hr
Supply Pressure
20 mbar
37 mbar
Burner Operating Pressure
10 mbar (*)
26 mbar (*)
Gas Connection
1
/
2
” BSP Male
Natural Gas
LP Gas
Input Rating
31.5 MJ/hr
31.5 MJ/hr
(N.H.G.C.)
(29.850 Btu/hr)
(29.850 Btu/hr)
Supply Pressure
1.13 - 3.4 kPa
2.75 - 4.5 kPa
(4.5” - 13.5” w.c.)
(11” - 18” w.c.)
Burner Operating Pressure
1.0 kPa (*)
2.55 kPa (*)
(4.0” w.c.)
(10.0” w.c.)
Gas Connection
½" BSP Male