Waring MX1300XTP Operating Manual - Important
10
11
• Cleanandsanitizemotorbasepriortoinitialuseandaftereachuse.
• Washingsolutionsbasedonnon-sudsingdetergentsandchlorine-based
sanitizingsolutionshavingaminimumchlorineconcentrationof100PPM
are recommended.
Thefollowingwashing,rinsing,andsanitizingsolutionsortheirequivalents
may be used.
SOLUTION
PRODUCT
DILUTION IN WATER TEMPERATURE
Washing
DiverseyWyandotte
4tablespoons
Hot115˚F(46˚C)
DiversolBX/aorCX/A
/gallon
Rinsing
PlainWater
Warm95˚F(35˚C)
Sanitizing
Clorox
®
1tablespoon/gallon
Cold50-70˚F
InstitutionalBleach
(10-21˚C)
• Inrepetitivebatch-processingapplications,frequentcleaningofthecon-
tainerwillprolongthelifeofthebladeassembly.Innocaseshouldactual
runningtimebetweencleaningsexceedone-halfhour.
• Donotusecontainertostoreprocessedfoodsorbeverages.
To Wash and Rinse Container
1. REMOVECONTAINERFROMMOTORBASE.Removelid.Rinse
container interior and lid under running water. Add washing solution to
container. Scrub and flush out the container interior and lid to dislodge
and remove as much food residue as possible. Empty container.
2. Wipedownexteriorofcontainerwithasoftclothorspongedampened
with washing solution. NOTE:Bladesaresharp.Handlecarefully.
Washlidandlidinsertinfreshwashingsolution.Fillcontainerone-quarter
full with fresh washing solution, cover, place on motor base, and run on
high speed for one (1) minute. Empty container.
3. Repeat step (2), using clean rinse water in place of washing solution.
IMPORTANT
INORDERTOMINIMIZEPOSSIBILITYOFSCALDING,TEMPERATURE
OFWASHINGSOLUTIONANDRINSEWATERMUSTNOTEXCEED115°F
(46°C),ANDQUANTITYUSEDMUSTNOTEXCEEDONE-QUARTER
CONTAINERFULL.
IFHIGHERTEMPERATURESORLARGERQUANTITIESAREUSED,
OBSERVEALLPRECAUTIONSGIVENINTHEOPERATINGMANUALUNDER
“HOTBLENDINGINSTRUCTIONS”,page8.
To Sanitize and Dry Container
1. Wipedownexteriorofcontainerwithasoftclothorspongedampened
withsanitizingsolution.
2. Fillcontainerwithsanitizingsolution,cover,placeonmotorbase,and
run on high speed for one (1) minute. Empty container. Dislodge any
residual moisture from blade assembly by placing empty container on
motor base, and running on high speed for two (2) seconds.
3. Sanitizelidandlidinsertbyimmersinginsanitizingsolutionfortwo
(2) minutes.
4. Donotrinsecontainer,lid,orlidinsertaftersanitizingiscompleted.
Allow parts to air dry.
To Clean and Sanitize Motor Base
1. UNPLUGPOWERCORD.Wipedownexteriorsurfacesofmotorbase
with soft cloths or sponges dampened with washing solution, rinse
water,andsanitizingsolution.Preventliquidfromrunningintomotor
basebywringingallexcessmoisturefromclothsorspongesbefore
using them.
DONOTIMMERSEMOTORBASEINWASHINGSOLUTION,RINSE
WATERORSANITIZINGSOLUTION.
2. Allow motor base to air dry before using.
Anyotherservicingshouldbeperformedbyanauthorizedservice
representative.