WarmlyYours FeelsWarm Installation Instructions Manual - Installation Instructions
Installation Instructions
SECTION 2
6
3. DRILL CABLE HOLE IN CABINET
A. Evaluate how the cable from the heater will reach the outlet inside the cabinet. Consider how the wire will feed and where
an access hole needs to be located in order to route the heater cable within the framework of the cabinet.
B. Determine where the cable hole can be located to successfully penetrate the cabinet without hitting supports, wires, or
other barriers. Use a stud finder or other method to determine a good location for the hole.
C. To ensure that the cable hole will go into the cabinet, drill a 1/16” hole and verify that the hole doesn’t hit a stud or other
obstacle. A 1/16” hole is recommended so that if a second hole has to be drilled, the original hole is small enough to
conceal with putty.
Note: In many cabinets, there is a horizontal support board in this area. In this case, drill the cable hole below the
horizontal support board to ensure the hole will enter the cabinet as needed.
D. Use a 3/4” spade drill bit to drill a hole in the cabinet wall(s)
E. The cable will feed from the heater into the cabinet where it plugs to the transformer, Thermal Control Unit, and outlet.
The plastic cable plug will be placed around the cable and inserted into the 3/4” hole for a professional look (as shown).
Approx. 72”
Thermal Control Unit
Approx. 60”
Approx. 42”
Approx. 24”
Heating Element
Transformer
To 120V House Outlet